5. TornaX, CyclonX™ and Vortex™ (except Vortex™1) Complete Test

5.1 Testing the robot

Vortex

family only

- Connect the Diag Box

- Connect the robot to the Diag Box using

 the 

grey adaptor for the CyclonX

, and floating 

cable for TornaX/ Vortex

Press “Cleaner” 

then “Start

/

Stop”

End

Press “Start

/

Stop” or “OK” 

or “Cancel”

t fd

t bd

test

P on

Poff

End

TornaX, 

Vortex™

CyclonX™ robot test

Change the Diag 

Box

Fail

-

 aT

Fail

-

 Com

Test effectué

Fail

-

 trac

Fail

-

 pump

TEST

Disconnect/reconnect 

the robot/Diag Box 

assembly

Press “Cleaner” 

then “Start

/

Stop”

Fail

-

 aT

TEST

Disconnect/reconnect 

the robot/Diag Box 

assembly

Press “Cleaner” 

then “Start

/

Stop”

Traction motor 

forward

Traction motor 

reverse

Pump motor 

start

Pump motor 

stop

TEST

OK

OK

OK

OK

TEST

TEST

SC

OK

Press “Cleaner” 

then “Start

/

Stop”

TEST

Rotation right 

test

Rotation left 

test

tcl

Tcc

Disconnect the robot and connect 

the motor unit to the Diag Box usig 

the brown connector

Press “Cleaner” 

then “Start

/

Stop”

Change the 

motor unit

Fail

-

 Com

Fail

-

 Com

TEST

OK

TEST

OK

Fail

-

 At

*

*

Refer to the fault description 

at the top of the flow chart

Dia6

Fail

-

 Com

**

Refer to the fault description 

at the top of the flow chart

Fail

-

 Com

**

Refer to the fault description at 

the top of the flow chart

*

*

Check in the connector 

on the cable side that 

the wires are correctly 

connected

Check in the connector on 

the cable side that the wires 

are correctly connected

OK

Press “Cleaner” 

then “Start

/

Stop”

TEST

Fail

-

 Com

Change the 

cable

OK

*

*

SC

SC

Test the motor 

unit

Check the 

transmission 

system and the 

propeller

Change the 

transmission system 

and/or clean the 

debris from the 

propeller

Change the 

motor unit

Unit OK

Unit 

NOK

Check 

OK

Problem on the 

transmission 

and propeller

Disconnect the motor 

unit and reconnect the 

robot to the Diag Box

*

*

*

*

SC

Test the 

motor unit

Change the 

motor unit

Change the 

robot cable

Unit OK

Unit 

NOK

CyclonX™

Vortex™

TornaX

TornaX

CyclonX™

Vortex™

TornaX

CyclonX™

Vortex™

Change the 

complete chassis

Change the 

complete chassis

Change the 

complete chassis

Summary of Contents for Diag box

Page 1: ......

Page 2: ...operations check that The voltage indicated on the appliance s information plate corresponds to the mains voltage The power grid is adapted to the power requirements of the appliance and is grounded T...

Page 3: ...ing with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or...

Page 4: ...test do not touch the robot or press the keys on the robot control unit Full Test This enhanced mode lets you view or export more detailed information number of hours operation error history etc To u...

Page 5: ...ortex 1 Test Robot TEST Connect the Diag Box Connect the robot to the Diag Box using the red adaptor Press Cleaner then Start Stop End Press Start Stop or OK or Cancel Vortex 1 robot test Dia6 Test En...

Page 6: ...n connector Press Cleaner then Start Stop Change the motor unit Fail Com Fail Com TEST OK TEST OK Fail At Refer to the fault description at the top of the flow chart Dia6 Fail Com Refer to the fault d...

Page 7: ...l box test Press Ebox then Start Stop Fail aT Press Ebox then Start Stop Disconnect reconnect the Diag Box Fail aT Change the Diag Box TEST OK Dia6 OK OK TEST TEST Fail OK Fail Com Change the control...

Page 8: ...nect the motor unit Diag Box assembly Press Cleaner then Start Stop Change the motor unit Fail Com OK TEST OK OK Rotation right test Rotation left test Fail trac Change the motor unit Fail pump Change...

Page 9: ...ption at the top of the flow chart Dia6 Pump motor stop Press Cleaner then Start Stop Connect the robot control box to the robot Connect the Diag Box Connect the robot control box to the Diag Box usin...

Page 10: ...8 Full Test enhanced mode with Full Test Software application 8 1 Downloading Full Test Software Before you use the tool for the first time download the Full test Software application from www zodiac...

Page 11: ...ctromagnetic compatibility directive 2004 108 EC EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2002 EN 60335 1 2002 A1 2004 A2 2006 A11 2004 A12 2006 EN 60335 2 41 2003 A1 2004 Relative to which...

Page 12: ......

Reviews: