background image

DIAG.030.A - EN - 2019-12

1

Technical procedure

• 

Alpha®iQ cleaners are not compati ble with:

-

the "Diag Box" diagnosti c unit;

-

the "Full Test Diag" diagnosti c soft ware;

• 

The diagnosis described in this procedure is available using a masked functi on from the control box delivered 

with the cleaner.

  

 1. Cleaner diagnostics

-

Test to be conducted out of the water.

-

Connect the cleaner to the control box delivered with the cleaner.

-

Connect the control box's power cable.

-

Turn the cleaner on its back (wheels facing upwards) when rotati ng the wheels forwards and backwards (tracti on 

test)

• 

On the control box, press 

 and hold for 10 seconds.

• 

Quick mode (fl oor only) fl ashes by default

 . For control boxes with a screen, the

 message "diAG" is displayed 

at the same ti me.

• 

Press 

 to start the 

cleaner's diagnosti cs. 

The diagnosti cs process will review the following 5 points in the given 

order and will stop as soon as an error is identi fi ed:

• 

During the cleaner's diagnosti cs sequence, do not look directly at the light beam coming from the motor unit.

COM

 (Communicati on)

tr1 

(Tracti on 1)

tr2 

(Tracti on 2)

PMP 

(Pump Motor)

SEnS

 (Sensor Unit) (depending on the 

model)

"Wait for the test to automati cally end" 

During the test:

• 

All of the control box's LEDs are fl ashing.

•  The motor unit's LEDs are lit.

• 

The sensor unit's LED fl ashes green and turns orange when testi ng the sen-

sor unit.

• 

Follow the instructi ons, see 

“2. Cleaner diagnosti cs results”.

Troubleshooti ng

Alpha™ iQ

Cleaner and control box diagnosti cs

Reviews: