Page 2
O-Ring
Cell
DC Cable
Large Collar
Vessel
Figure 1.
Installation of the Electrolytic Cell
Assembly
H0345000-
3. Close valves between filter and pool to prevent
pool draining.
4. Unplug the DC cable from the electrolytic cell.
See Figure 1.
5. Turn the large collar counterclockwise to remove
and save for reinstallation.
6. Remove the O-ring and discard.
7. Remove the existing the electrolytic cell from the
vessel.
8. Install the O-ring provided in the kit. Make sure
the O-ring is seated properly.
IMPORTANT
Make sure the O-ring is secure in the groove on the
vessel top, not on the underside of the cap.
9. Install the new electrolytic cell into the vessel.
10. Hand tighten the large collar. Do not over tighten.
11. Plug the DC cable into the electrolytic cell. Press
cable down firmly onto ports.
12. Reset valves and switches. Turn pump and
sanitizer on. Wait five (5) minutes for system to go
through its diagnostics.
13. Confirm chlorine output and settings on the user
interface.
14. For operating instructions, please refer to the
Nature
2
Fusion Soft Installation and Operation
Manual, originally supplied with the product.