Page 2

O-Ring

Cell

DC Cable

Large Collar

Vessel

Figure 1. 

Installation of the Electrolytic Cell 

Assembly

H0345000-

3.  Close valves between filter and pool to prevent 

pool draining.

4.  Unplug the DC cable from the electrolytic cell. 

See Figure 1.

5.  Turn the large collar counterclockwise to remove 

and save for reinstallation.

6.  Remove the O-ring and discard.
7.  Remove the existing the electrolytic cell from the 

vessel.

8.  Install the O-ring provided in the kit. Make sure 

the O-ring is seated properly.

  

IMPORTANT

Make sure the O-ring is secure in the groove on the 

vessel top, not on the underside of the cap.

9.  Install the new electrolytic cell into the vessel.
10.  Hand tighten the large collar. Do not over tighten.
11.  Plug the DC cable into the electrolytic cell. Press 

cable down firmly onto ports.

12.  Reset valves and switches. Turn pump and 

sanitizer on. Wait five (5) minutes for system to go 

through its diagnostics.

13.  Confirm chlorine output and settings on the user 

interface.

14.  For operating instructions, please refer to the 

Nature

2

 Fusion Soft Installation and Operation 

Manual, originally supplied with the product.

2.  Parts List

The following table is for your reference. To order 

additional parts, please contact your local distributor.

DESCRIPTION

R0502800

R0503000

Electrolytic Cell Assembly

1

1

O-Ring, Large Collar

1

1

Instructions

1

1