P a g e
|
27
Problem
Possible Cause
Corrective Action
Flow light is on (Display says “No Flow”).
Caused by insufficient water flow through
the pod and cell.
NOTE
When the Flow light is on,
the chlorine output will be
turned off.
The pump or skimmer
baskets are filled with debris
preventing sufficient water
flow through the system.
Check and clean the pump and
skimmer baskets.
Dirty filter.
Clean the filter.
Closed valves.
Check and correct all valve
alignments.
Pump fails to provide
sufficient water flow.
Check for correct operation of the
pump.
Make sure pump is sized properly for
required flow rate.
Flow switch connection
loose.
Check that the flow switch is properly
connected to the power pack.
Flow switch failure.
Replace the flow switch.
Problem
Possible Cause
Corrective Action
Salt light is
on
and the display says “Check
Salt or Low Temperature”.
NOTE
The Salt light will turn on
when the salt level drops well
below 3,000 ppm and it will
remain on until the salt level is
raised above 4,000 ppm.
* If and AquaLink™ RS or PDA is
installed, when the salt level is low, the
AquaLink RS or PDA will display, “Salt
2900 PPM, Check AquaPure
®
, (Low
Salt)”.
Salt level is well below 3,000
ppm, depending on water
temperature.
Maintain a salinity level of
4,000 ppm - 4,500 ppm
(see Section 4.6 or contact
your local pool professional).