Manual Zocon Z300 Seed drill
4. CONNECTION
•
Electric thread and control command are included with the Z300
•
N°1513 (on technical doc): for starting the blower system
•
N° 1514 (on technical doc): for starting the rotor
•
The handle button N° 1512 graduated from 0 to 30 to set the electric flow
•
Supply protected connection of 30 amperes is necessary
•
Connect the red thread with the positive plug + (brown thread) and the blue one with
the negative plug -
•
Check the blower rolls in the right direction (arrow direction)
5. SECURITY RULES
After fitting the Z300 on the tool, check the different points of fixation, all the fixation holes of
the chassis should be used to insure a good stability of the Z300 on the tool. Depending on
the highness of the fitting you should provide a “passerelle” to access easily to the Z300 with
no slipping steps large from 28 to 35cm and high from 50 to 55cm from the ground. To
prevent any respiratory problems, please fill and empty the tank with adapted protection
(mask…) Before any manual work on the machine plug it off.
6. FITTING THE FLOW
The flow is regulated by a rotor working with an electric motor combined with an electronic
control command fitted in the cabin which permits the kg/hour set.
A graduated scale regulates the flow. A switch is used for the stop/go set.
As the Z300 is checked, the rotor motor and the blower system work in the right direction.
As the hopper is under pressure, use the Z300 with closed hopper.
EMPTYING THE HOPPER: a trap at the rotor end is dedicated for emptying.*
CHANGING THE ROTOR: unscrew the two buttons, take off the trap, pull the rotor, put in
the new rotor with the square side first, then close the trap, and screw the buttons.
STOCK THE DRILL COVERED..
7. FLOW SET:
The table set is given in flow/hour:
Working width x speed x weight/hectare