Use the holes(5.0mm) marked '

'. To create the conductive connection (frame is anodized), use

Stainless steel M5nut, two Stainless steel cut washer, Stainless steel M5 plain washer, Stainless steel
M5 spring washer ,

M5

copper wire ,and Stainless steel M5 bolt.

1. Copper wires with M5 cupped washer should be placed through the bolt;
2. Put the cut washer through the bolt, and the bolt must be put through the hole fixed in the aluminum

frame;

3. Use the nut and cut washer to fix all the parts. The copper wire can not be attached to the aluminum.

Do not interrupt or influence the conductive connection when making daily maintenance .All the
crunodes on the conductive connection must be fixed. The fastness does not depend on soldering.

5、

Suggested maximum number of modules in parallel and in series

When designing the system, we Suggested maximum number of modules in parallel and in
series for [Vsys/(1.25Voc)]/1

fuse rating/Isc+1.

Summary of Contents for ZXM6-HD120

Page 1: ...ntenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personne...

Page 2: ...Nominal Mass kg 26 5kg 22 5kg 24 5kg 24kg 23kg 22kg 22kg 21 5kg Package Size mm 2000 992 25 27 30 35 2024 1002 25 27 30 35 2020 1002 25 27 30 35 2040 1002 25 27 30 35 1844 992 25 27 30 35 1860 1002 25...

Page 3: ...r fountain Antisepsis keep away from salt erode and sulfuration places Do not wear rings jewelry watches or other metallic items while working with photovoltaic modules 3 Mounting and notes The module...

Page 4: ...be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will be satisfactory during the rest of the year The module tilt angle is measured between t...

Page 5: ...t and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influe...

Page 6: ...ules are strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used must not come into contact with the front glass and mu...

Page 7: ...m compression for each clamp is 20MPa 2900PSI The module mounting structure must be made of durable corrosion resistant and UV resistant material All mounting hardware bolt flat washer split washer nu...

Page 8: ...le material Use cable extensions and plugs that are designed for outdoor application Ensure that they are in perfect electrical and mechanical condition Use only cables having one conductor Select the...

Page 9: ...k on the rear of the module using sharp objects Exercise utmost caution when working on wiring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concent...

Page 10: ...ass 5 as mono panels doped with gallium non coated glass 7 as mono panels doped with boron coated glass 8 as poly panels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8...

Page 11: ...400 405 Max Power Voltage Vmp V 40 6 40 8 41 41 2 Max Power Current Imp A 9 61 9 69 9 76 9 84 Open Circuit Voltage Voc V 48 7 48 9 49 1 49 3 Short Circuit Current Isc A 10 08 10 21 10 27 10 33 Module...

Page 12: ...STC Model Type ZXM6 HLD120 315 M ZXM6 HLD120 330 M Max Power Pm W 315 330 Max Power Voltage Vmp V 33 3 33 9 Max Power Current Imp A 9 47 9 74 Open Circuit Voltage Voc V 40 40 6 Short Circuit Current I...

Page 13: ...oltage VDC 1500 A Max Series Fuse A 15 Electrical Performance STC Model Type ZXP6 HLD132 315 P ZXP6 HLD132 330 P Max Power Pm W 315 330 Max Power Voltage Vmp V 35 1 35 7 Max Power Current Imp A 8 98 9...

Page 14: ...r Voltage Vmp V 32 5 Max Power Current Imp A 9 24 Open Circuit Voltage Voc V 39 5 Short Circuit Current Isc A 9 58 Website www znshine com Address 1 Zhixi Industry Zone 213251 Jintan Jiangsu PEOPLE S...

Reviews: