ZMC306N Motion Controller User Manual V1.5
Cable pair
4
Isolation
cross skeleton
Connector
Crystal head with iron shell
Cable material
PVC
Cable length
Less than 100m
Use RJ45 network cable connection method:
⚫
When installing, hold the crystal head with the cable and insert it into the RJ45
interface until it makes a "click" sound (kada).
⚫
In order to ensure the stability of communication, please fix the cables with cable ties.
⚫
When disassembling, press the tail mechanism of the crystal head and pull out the
connector and the module in a horizontal direction.
Please use tube-type pre-insulated terminals and cables with appropriate wire
diameters to connect the user terminals.
3.11.
AXIS Differential Pulse Axis Interface
This product provides 2 local differential pulse axis interfaces, each interface is a
standard DB26 female socket. Each terminal provides 0V and +5V output, which can
provide 5V power for the encoder.
Before the axis is used, the use mode of the axis must be configured through the
ATYPE parameter.
→
Interface Definition
Interface
Pin
Signal
Description
1
EGND
Negative pole of OVCC
2
IN24-
25/ALM
Digital input (recommended as
driver alarm)
3
OUT16-
17ENABLE
Digital output (recommended as
driver enable)
4
EA-
Encoder differential input signal A-
5
EB-
Encoder differential input signal B-