background image

WS-100
English

Size: 5cm x 10 cm, total: 20cm x 30cm (H)

WS-100

In Wall Switch

ZLINK’s WS-100 is a Z-Wave Plus cer�fied device with S2 security and SmartStart 

features. You can now add this device securely and with ease using QR code on 

the product with compa�ble gateways suppor�ng S2 and Smart Start. ZLINK 

WS-100 replaces a standard in-wall light switch turning it into a Z-Wave controlled 

network device with manual and remote ON/OFF control. ZLINK WS-100 supports 

“Instant Feedback” of manual status to compa�ble gateways as well as Central 

Scene to allow se�ng mul�ple scene control throughout the home, with gateways 

suppor�ng Central Scene. Each Z-Wave device serves as a node to repeat the 

signal in the network, thus, extending the overall Z-Wave mesh wireless network 

range. For more informa�on on this and other quality ZLINK Products please visit 

www.ZLINKProducts.com 

• Power 120 VAC, 60Hz, up to 1800 wa�s

• Region US: 908.4, 916 MHz

• Works with incandescent, CFL & LED lights

• Remotely or manually turns ON or OFF lights

• Fits standard wall plates (wall plate not included)

• Works with any cer�fied gateway suppor�ng Z-Wave

• Please find the QR code label with DSK on the front metal yoke of the device

This product speaks 

with other Z-Wave 

cer�fied devices

INTRODUCTION

FEATURES

Note: If Inclusion s�ll fails a�er the 2nd a�empt, you need to 

first reset the device before repea�ng the above steps. The 

manual reset method is as follows:

1. Turn the connected ligh�ng ON with the rocker

2. Quickly tap the top paddle 3 �mes then the bo�om 3 �mes

The connected ligh�ng can be controlled manually with a rocker 

OR Wirelessly with a remote controller

If you see the ligh�ng turns OFF and then ON, it means that 

the device has been reset successfully and you may retry 

Step. 5 above to add the device into your network. 

Otherwise, please repeat the manual reset procedures.               

Use the manual reset procedure only in the event that the network primary controller 

is lost or otherwise inoperable.

Manual Reset

A Z-Wave cer�fied controller is capable of se�ng up ZLINK products in your 

desired network. Once the device is added, you may assign it to a Group.  

Furthermore, it can be set in Associa�on with another Z-Wave device to 

perform a specific triggered func�on such as turning lights on when mo�on 

is detected. Please refer to the instruc�ons manual of your controller for 

details and procedures on how these se�ngs can be done. 

BASIC OPERATION

Step 3

 Remove the wall plate and the exis�ng 

switch (if mounted) at your preferred installa�on 

loca�on. You should label the wires connected to 

the screw terminals before disconnec�ng the 

switch. Please check that the wiring configura�on 

to the right is present in the wall switch box, 

otherwise consult a qualified electrician. 

IMPORTANT: WS-100 requires LINE, NEUTRAL and LOAD wires for every installa�on

LINE (Hot) - Black (connected to power) 

NEUTRAL - White (this wire is o�en �ed to other 

neutral wires and may require the included jumper 

cable to connect with WS-100) 

LOAD - Black (usually �ed closely to Traveler wire ) 

TRAVELER — Red/Other (only used in 3-way circuits)

GROUND — Green or Bare 

Traveler

(Red/Other)

Neutral

(White)

Line (HOT)

(Black)

Load

(Black)

Ground

(Green/Bare)

wire hole

Iden�fying the wiring terminals on the module

WARNING! RISK OF SHOCK! Make sure power is OFF in the circuit before wiring!

Step 1

RISK OF FIRE, ELECTRICAL SHOCK & BURNS

DO NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENT 

No user serviceable parts are in this module

The appliance connected to WS-100 must not exceed 900W incandescent, 

200W CFL/LED, ½ horsepower motor and 15A, 1800W resis�ve load. 

SETUP

Step 2

1

2

3

4

5

4 wires for 2-way circuit

5 wires for 3-way circuit

1. Line(Hot) - Black

2. Neutral - White

3. Ground – Green or bare

4. Traveler (for 3-way) – 

Red or other  

5. 

Load - Black

Gang Box

To install the WS-100 in a mul�-gang or J box, the tabs on the sides of the metal 

yoke may need to be removed. For single gang switch, no changes should be 

required.  For dual or higher gang configura�on where switches are next to each 

other, the tabs need to be removed.  Simply take a pair of pliers, grab the tabs 

and wiggle un�l the tabs break off.

Step 4

 When proper wiring is completed, secure the device to the wall box. Restore power to 

the circuit to test if the connected ligh�ng can be turned ON or OFF manually by the rocker on 

the device before remoun�ng the wall plate. Also observe the status change of the LED 

indicator to ensure the device is in normal opera�ng mode. If WA-100 Auxiliary Switch is used 

for a 3-way connec�on, please also test if it can control the ligh�ng.  

Step 5

 Add(Include) the device into your network by a Z-Wave cer�fied controller. Please refer 

to the controller’s instruc�ons manual for details.  Normally, this requires pu�ng your controller 

so�ware in Add New Device (inclusion) mode. When this process is ini�ated in the controller 

so�ware, single click and release the rocker switch.  The controller so�ware should indicate that 

the ac�on was successful.  If the controller shows it was a fail, repeat the procedure.

Wiring Informa�on

Making Connec�ons

2-Way circuit

Screw terminal

Hole

Neutral

(White)

Line (HOT)

(Black)

Load

(Black)

Ground

(Green/Bare)

Use copper wires only. UL specifica�on: the �ghtening 

torque for the screws is 14 Kgf-cm (12 lbf-in)

Strip insula�on 5/8" (16mm)

Wire connec�on can be made either to Screw 

terminal or Hole. A 14 gauge wire can use hole or 

screw terminal, all other gauges must use screw 

terminal.

1

2

3

5

Neutral

(White)

Line (HOT)

(Black)

Load

(Black)

Ground

(Green/Bare)

1

2

Traveler

(Red/Other)

4

3

5

1

2
3

5

The Traveler terminal is not 

used in a 2-way circuit. Do 

not remove the insula�on 

tape on the Traveler 

terminal in this applica�on.

Please refer to WA-100 user manual for 

wiring instruc�ons of the auxiliary switch. 

The maximum length of Traveler wire may 

not exceed 200�.

Hot

Load

Neutral

Neutral

Load

Line

120VAC

60Hz

Traveler

WD/WS-100

Ground

Hot

Load

Neutral

Neutral

Neutral

Load

Line

120VAC

60Hz

Traveler

Traveler

WD/WS-100

WA-100

Ground

Ground

About the rocker switch:

Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing 

the upper part of the rocker turns the appliance ON. Tapping and releasing the lower 

part of the rocker turns the appliance OFF. 

In the event of a power failure, the ZLINK device will return to the last se�ng 

a�er the power is restored.

You may also manually turn off LED with the rocker switch by the 

following procedure.
Quickly press the top (ON) rocker switch 2x and the bo�om (OFF) of 

the rocker 2x.  If successful, the LED indicator will always be OFF 

regardless of the load status. Repea�ng the procedures above 

restores the factory default.

www.ZLINKProducts.com

Connecting Things That Matter

www.ZLINKProducts.com

WS-100 User Guide

3-Way circuit

WA-100 companion switch required

Reviews: