12
Pow
er Rating & Electrical Connection
ELECTRIC POWER RATING
RANGE SIZE
AMPERAGE
VAC
PLUG
RG24 series ranges
5A
110/120 VAC
NEMA 5-15P
RG30 series ranges
5A
110/120 VAC
RG36 series ranges
5A
110/120 VAC
RG48 series ranges
10A
110/120 VAC
The appliance shall be connected to a single phase electric line rated at 110-120VAC
and 60HZ frequency. The true voltage in most homes is usually within this rating. A
properly grounded and horizontally-mounted NEMA 5-15P electrical outlet should be
installed in the wall behind the range at least 2" (51 mm) above the floor and not more
than 8" (203 mm) from the bottom left side (facing product).
L2 (red)
N (white)
G (green)
L1 (black)
L2 (red)
N (white)
G (green)
L1 (black)
cable from
power supply
Four-Wire Connection
Receptacle
NEMA 14-50R
ELECTRICAL GROUNDING
Our oven is equipped with a three-prong plug for your protection against shock hazard
and should be plugged directly into a properly grounded receptacle. Do not cut or
remove the prong from this plug.
Disconnect electrical power at the circuit breaker box or fuse box
before installing the appliance� Provide appropriate ground for the
appliance� Use copper conductors only� No attempt should be made to
operate the appliance during power failure�
WARNING
INSTALLATION