14
INSTALLATION
VENTILATED CABINET
• This appliance is only intended to be fully fitted in a kitchen. This appliance is not
designed to be used as a tabletop appliance or inside a cupboard.
• The fitted cabinet must not have a back wall behind the appliance.
• A gap of at least 1 3/4” must be maintained between the wall and the base or
back panel of the unit above.
• The fitted cabinet must have a ventilation opening of 38 3/4 in² in the base. To
achieve this, cut back the base panel or fit a ventilation grill.
• Ventilation slots and intakes must not be covered.
• The safe operation of this appliance can only be guaranteed if it has been
installed in accordance with these installation instructions.
• The units into which the appliance is fitted must be heat-resistant up to 194°F.
• Note: There should be a minimum 1/16” gap above the oven.
MWO-24
MWO-30
Cabinet R
equir
ements