WARNING!
A manual valve shall be installed in an accessible lo-
cation in the gas line external to the appliance for
the purpose of turning on and shutting off the gas
to the appliance.
Do not use aerosol sprays in the vicinity of this
appliance while it is in operation.
Room Ventilation: An exhaust fan may be used with
the appliance; in each case it shall be installed in
conformity with the appropriate national and local
standards. Exhaust hood operation may affect other
vented appliances; in each case it shall be installed in
conformity with the appropriate national and local
standards.
Type of Gas
This appliance is shipped from the factory for use
with natural gas. For use with propane LP gas please
follow the conversion procedure described on pg. 14.
A step by step conversion procedure is also included
with each set of LP gas nozzles.
Gas Pressure
The
maximum
inlet gas supply pressure incoming to
the gas appliance pressure regulator is 34PSI (13,8w.
cpr 3,5kPA).
The
minimum
gas supply pressure for checking the
regulator setting shall be at least 1
˝
w.c (249 Pa)
above the inlet specified manifold pressure to the ap-
pliance (This operating pressure is 4
˝
w.c. (1.00kPa)
for Natural gas and 11
˝
w.c. (2.75 kPa) for LP gas.
Before Installation
This appliance shall only be installed by an autho-
rized professional.
The appliance shall be installed in accordance with
the standards of the country where it will be in-
stalled. The installation of this appliance must con-
form to local codes and ordinances. In the absence of
local codes installation must conform to American
National Standards, National fuel Gas code ANSI
Z223.1-Latest edition/NFPA 54 or B 149.1.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
code, ANSI/NFPA 70.
If local codes permit, a flexible metal appliance con-
nections with the new AGA or CGA certified design,
max 5 feet (1,5m) long, 34
˝
I.D. is recommended
for connec
t
ing
this appliance to the gas supply line.
DO NOT bend or damage the flexible connector
when moving the appliance.
This appliance must be used with the pressure reg-
ulator provided. The regulator must be properly in-
stalled in order to be accessible when the appliance
is installed in its final location.
T
h
e pressure
regulator must be set for the type of gas to be used.
The pres-sure regulator has 34
˝
female pipe thread.
The appro-priate fitting must be determined based
on the size of your gas supply line, the flexible metal
connector and the shut-off valve.
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 34
PSI(13,8w.cpr 3,5kPA).
All opening holes in the wall and floor, back
a
nd
under the appliance shall be sealed before installa-
tion of the appliance.
5
Summary of Contents for 30"
Page 1: ...Range Installation Guide and Users Manual...
Page 4: ...3 5 6 7 8 8 9 10 11 12 14 15 15 16 17 18 18 20 22 23 24 26 2 Location of Appliance Tags...
Page 6: ...Product Specifications Dimensions 4...
Page 11: ...9...
Page 13: ...Wiring Schematic Diagram Places on Backside of Panel and on Installation Booklet 11...
Page 24: ...Important User Information 22...