PCIeCANFD-200U/100U
PCIeCANFD Series CANFD Interface Card User Manual
©2021 Guangzhou ZLG Electronics Corp.,Ltd.
2
User Manual
⚫
Support CAN2.0A and B protocol and comply with ISO11898-1 specification;
⚫
Compatible with high-speed CAN and CANFD;
⚫
The CAN interface is electrically isolated from 3,500 V DC;
⚫
The CAN communication baud rate can be arbitrarily programmable between 4 Kbps and 1 Mbps;
⚫
The CANFD baud rate can be arbitrarily programmable between 1 Mbps and 5 Mbps;
⚫
Maximum data flow for single channel transmission: 4,000 frames per second (remote frame, single frame
transmission);
⚫
The highest data flow rate received by a single channel: 10,000 frames per second (remote frame);
⚫
Built-in 120 ohm terminal resistance, which can control access and disconnection;
⚫
Support ZCANPRO test software (support Windows 7 and Windows 10);
⚫
Operating temperature: 0°C to 80°C;
⚫
Storage temperature: -20°C to +70°C;
⚫
Length, width and height: 102.6 mm x 120.02 mm x 21.59 mm.
1.3 Product Specifications
1.3.1 Electrical Specifications
The PCIeCANFD interface card needs an electrical environment to work safely and stably. Table 1.1 lists the
electrical parameters of the interface card. Exceeding the parameters listed in the table may cause the product to
work unstable and fail, or even burn the module.
Table 1.1 Electrical specifications of PCIeCANFD interface card
Item
Test Conditions
Minimum
Typical Value
Maximum
Unit
Working
voltage
PCIe interface power
supply 12V
Two CAN transceivers
11
12
13
V
Operating
current
External input DC power
supply
VIN=12V
--
85
--
mA
CAN interface
Bus pin withstand voltage
CANH, CAHL
-42
--
42
V
Terminal resistance
Enable terminal
resistance
--
120
--
Ω
Isolation withstand voltage
Leakage current less
than 1 mA
--
3500
--
VDC
1.3.2 Operating Temperature
The applicable operating temperature range of PCIeCANFD interface card: 0°C to +80°C. Using the interface
card in too low or too high ambient temperature will make it work abnormally and shorten its service life.
1.4 Typical Applications
⚫
CAN(FD)-Bus network diagnosis and test
⚫
Electric power communication network
⚫
Industrial control equipment
⚫
High-speed, large data volume communication