2.6  Board Installation 

2.6.1  Precautions 

PCIeCANFD-400U  series  interface  cards  are  electrostatic  sensitive  products  and  should  be  packed  in  a 

special  anti-static protective  bag  before  delivery.  Therefore, when  operating the  interface  card,  take necessary 

protective measures to ensure that the interface card is not damaged by human contact with static electricity. 

The  PCIeCANFD-400U  interface  card  should  be  installed  when  the  PC/industrial  computer  has  been 

powered  off

.  Similarly,  the  interface  card  should  also  be  disassembled  when  the  PC/industrial  computer  is 

powered off. 

PCIeCANFD-400U series interface cards do not have any switches and jumpers for assigning interrupts and 

I/O addresses, which are automatically assigned by the computer BIOS. Therefore, the board must be installed in 

the PCI-E slot before you install the driver. The installation procedure is as follows: 

1.  Power off the computer and open the computer case cover; 

2.  Insert the PCIeCANFD-400U series interface card into a free PCI-E slot, x1, x4, x8, or x16 slot; 

3.  Tighten the screws to fix the board; 

4.  Power  on  the  computer.  At  this  time,  the  BIOS  automatically  assigns  interrupts  and  I/O  addresses  to  the 

PCIeCANFD-400U interface card; 

5.  Install the driver. 

 

Figure 2.6 Removing and inserting the PCIeCANFD-400U series CAN interface card 

Note: Do not remove or insert the PCI-E interface card with power on; do not touch the device with your hands 

during installation to prevent static electricity from damaging the device.

 

2.6.2  Product Dimensions 

The physical dimensions of PCIeCANFD-400U are 117 mm x 120.02 mm (including metal baffle). Figure 2.6 

Summary of Contents for PCIeCANFD-400U

Page 1: ...industrial computer to be connected to CAN CAN FD network through the PCI E interface which constitutes a data acquisition and data processing system in CAN CAN FD network applications such as laborat...

Page 2: ...PCIeCANFD 400U PCIe Interface CAN FD Card 2022 Guangzhou ZLG Electronics Co Ltd User Manual Revision History Version Date Description V1 0 March 18 2021 Created...

Page 3: ...ypical Applications 4 2 Hardware Interfaces 5 2 1 CAN Communication Interface 5 2 2 DB 9 Connector Definition 6 2 3 DB 37 Connector 6 2 4 Terminal Resistance 8 2 5 System Indicators 9 2 6 Board Instal...

Page 4: ...ming to CAN FD ISO 11898 1 2015 specification compatible with CAN 2 0A B standard It supports a transmission rate of up to 5 Mbps which enables flexible and convenient applications To improve system r...

Page 5: ...ceived by a single channel 10 000 frames per second remote frame Built in 120 ohm terminal resistance which can be connected and disconnected through the DIP switch Support ZCANPRO test software suppo...

Page 6: ...pport Support Linux system driver Support Support Support VxWorks driver Support Support Dimensions length x width PCB dimensions 110 x 99 60 mm Overall dimensions 102 6 mm x 120 02 mm x 21 59 mm incl...

Page 7: ...ce pins meets the requirements of the CiA standard Figure 2 3 shows the definition of the DB37 signal and Table 2 1 lists the definition of the DB9 pin signal As shown in Figure 2 1 the cable labels 0...

Page 8: ...ed cable 6 CAN_GND Reference ground 7 CAN_H CAN_H signal cable 8 NC 9 NC The signal from the DB 9 connector can be transferred to the 5 pin OPEN5 connector through the optional DB9 OPEN5 converter Tab...

Page 9: ...16 NC 35 CAN_SHIELD Shielded wire 17 CAN_GND Reference ground 18 CAN_H CAN_H signal cable 36 NC 15 NC CAN1 11 NC 14 CAN_L CAN_L signal cable 33 CAN_GND Reference ground 30 NC 12 CAN_SHIELD Shielded ca...

Page 10: ..._3 and S1_4 to select whether the terminal resistance of the corresponding CAN0 CAN1 CAN2 and CAN3 channels is connected to the bus network As shown in Figure 2 4 set whether the CAN channel uses the...

Page 11: ...igure 2 5 System indicators Table 2 1 Indicator functions Indicator Status Description FPGA_RUN Green Device running properly CANX_RUN Green CAN channel start Red CAN channel error Light off CAN chann...

Page 12: ...signing interrupts and I O addresses which are automatically assigned by the computer BIOS Therefore the board must be installed in the PCI E slot before you install the driver The installation proced...

Page 13: ...ecessary to connect CAN_L to CAN_L and CAN_H to CAN_H signals The CAN bus network adopts a linear topology and the two terminals of the bus need to be installed with 120 ohm terminal resistors if the...

Page 14: ...le layer shielded wire The equipment iron shell in the pictures refers to the outer shell of the device which is grounded by default Regardless of the type of cable reasonable changes must be made acc...

Page 15: ...Driver under Windows When the computer is shut down insert the PCIeCANFD interface card into the PCIe card slot of the computer and start the computer Click the official driver installation applicati...

Page 16: ...PCIeCANFD interface card is normal appears in the device manager indicating that the driver is installed correctly and a PCIeCANFD interface card is inserted At this time the CANFD card has been conn...

Page 17: ...Electronics Co Ltd 15 User Manual 4 Packing List Table 5 1 PCIeCANFD 400U Packing List V1 00 No Name Quantity Unit Remarks 1 PCIeCANFD 400U interface card 1 Piece 2 DB 37 to 4xDB 9 cable 1 Nr 3 After...

Page 18: ...e and powerful and it is a good helper for CAN bus testing monitoring diagnosis and development ZCANPRO software can be downloaded from the ZLG Electronics official website http www zlg cn 5 2 Using P...

Page 19: ...update this manual without prior notice To get the latest version please visit the official website of ZLG Electronics regularly or contact ZLG Electronics Thank you Right to modify the document Guan...

Page 20: ...Dreams come true with professionalism and dedication Guangzhou ZLG Electronics Co Ltd For more details please visit www zlg cn Welcome to call the national service hotline 400 888 4005...

Reviews: