Number of
TCP
connections
(number of
destination IP
segments)
1
When CANET-8E-U works in TCP Sever, each CAN
port can have a maximum of 255 TCP connections by
default without configuration;
When working in TCP Client mode, this item is used to
define the number of connection IP segments allowed
to be established during communication with the
corresponding CAN port. The maximum value is 6
segments.
When working in UDP mode, this item is used to define
the number of IP segments where the network device
communicating with the corresponding CAN port is
located. The maximum value is 6 segments.
Destination
port 1
8001-8004
Available values are 1 to 65535. Only valid in TCP
Client and UDP working modes. Used to define the port
of the network device that communicates with the
CANET device. Only the network data sent through this
port can be received by the CANET device, and the
data frame received by the CAN port of the CANET
device will also be sent to this port through Ethernet.
The default CAN0 destination port 1 is 8001, CAN1
destination port is 8002, CAN2 destination port is 8003,
and destination port CAN3 is 8004.