Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com
16
9153-5 are connected to each other, and the TCP Link lights of 9153-3 and
9153-5 are also highlighted, indicating that the above network configuration is
correct. When there is serial data communication, the ACT light of the two
devices will be on at the same time, indicating that the data is transmitted
between the two.
6. 485 Character
ZLAN5143 meet the RS485 standard, each ZLAN9153 can be with 32 terminal 485
devices. The maximum communication distance is 1200 meter, the resistance of 485
terminal is 120 ohms, usually must use terminal resistance when wiring over 300m.
Pay attention to the wiring, 485+ and 485- must be a twisted-pair, in order to reduce
signal interference.
7. Model Choice
Model
Instruction
ZLAN9153-3
A-end device
ZLAN9153-5
B-end device
Fiber jumper
SC interface, 1m. Non-standard equipped, if need please
purchase separately.
Power adapter
9V1A, 220V input, standard equipped.
8. After-service
Shanghai ZLAN Information Technology Co., Ltd.
Address: 12 floor, D building, No. 80 CaoBao road, Xuhui District, Shanghai, China
Phone: 021-64325189
Fax: 021-64325200
Web: http://www.zlmcu.com
Email: [email protected]