ZKRF20M Installation Diagram
4.2.2
Dual Detection Channel Operating Mode
Here is a dual-detection channel operating mode consisting of one transmitting unit and two receiving
units.
ZKRF10M Installation Diagram
ZKRF20M Installation Diagram
4.2.3
Multi-detection Channel Operating Mode
You can use different numbers of transmit and receive units to form more detection channels to work to
meet the needs of an ultra-wide entrance and exit scenario.
One thing that must be noted is that if there are 2 or more transmitting units working at the same time
and the installation position is within 10m, you must connect them using a signal synchronization cable.