User’s Manual for IP Camera (ZKIR5/ZKMD5/ZKIP5)
4
ZKIR5 series as an example
Power Interface (DC 12V)
: Connect to the adapter. This IPC employs the power supply of DC 12V and no lower than 1A.
Do not use any different power supply as it may damage the camera.
Network Interface (LAN)
: 10/100M selfadapting Ethernet interface is used to connect the camera with various network
equipments, such as, switch, router and hub. When it is connected to 10M network, the orange lamp is also on. When it
is connected to 100M network, the green lamp is always on.
Reset Button (RESET):
When the camera fails to function during incorrect operation or accidental failure (e.g. forget IP
address or password), or it is used in different scenes, press down the button for above 8s after a delay of 30s from
powering on to restore the camera to its factory default. The default user’s name is
admin
, the default password is
admin
and the default IP address is
192.168.1.88
.
1.6 Basic Procedure
1.
Unpack and check whether any component is missing.
2.
Connect the camera to computer by means of patch cable.
3.
If your computer IP is in a network section different from camera IP, please set it to the same network section as
camera IP, such as, 192.168.1.87.
4.
Log in the camera through client software or browser to check whether the video functions normally.
5.
Adjust the code stream and other video parameters.
6.
Modify the network parameters of camera and reboot the device.
7.
Repeat Step 3.
8.
Revisit the camera through client software or browser to check till the video functions normally.
9.
Install the camera and adjust the camera angle to the appropriate area.
10.
Visit the camera through client software or browse for video monitoring.