background image

 

2-2 Parts of the scanner 

 

 

Figure 2-1 

① 

LED 

② 

Beeper 

③  

Scan window 

④ 

Trigger 

⑤ 

Release-hole of the cable 

⑥ 

Cable interface port 

Summary of Contents for ZKB200

Page 1: ...USER MANUAL ZKB200 Handheld Image Scanner Version 1 0 Date April 2018 ...

Page 2: ... the user is on a licensed basis 2 The right is reserved to make changes to any software or product to improve reliability function or design 3 The material in this manual is subject to change without notice 4 A standard packing includes a scanner a USB cable and a CD or a user manual Accessories include a stand a RS 232 cable and a 5 VDC adaptor ...

Page 3: ...setting by scanning1Dbarcodes 10 3 2 Example 2 Multiple parameter setting by scanning a QR code barcode 11 3 3 Operate the scanner by receiving command via UART 12 3 4 Interface selection 13 3 5 RS 232 interface 14 3 6 USBinterface 17 3 7 Scan mode some global settings 20 3 8 Indication 27 3 9 Decodeilluminationanddecodeaimingpattern 28 3 10 Other settings 3 3 11 UPC A 33 3 12 UPC E 35 3 13 UPC E1...

Page 4: ...73 3 35 HanXinCode 74 3 36 Aztec Code 75 3 37 MicroQR Code 76 3 38 G1 G6 C1 C3 FN1 substitution string setting 77 3 39 G1 G4 stringposition Code ID position 82 3 40 String transmission 83 4 Maintenance 86 5 Barcode representing non printable character 87 6 ASCII Table 88 7 Testbarcode 89 8 Quicksettingtoenable disableAuto detection 92 9 Returndefaultparameters listfirmwareversion 93 10 Configurati...

Page 5: ...fference Decoding Capability 1D UPC A UPC E UPC E1 EAN 13 EAN 8 ISBN Bookland EAN ISSN Code 39 Code 39 full ASCII Code 32 Trioptic Code 39 Interleaved 2 of 5 Industrial 2 of 5 Discrete 2 of 5 Matrix 2 of 5 Codabar NW7 Code 128 UCC EAN 128 ISBT 128 Code 93 Code 11 USD 8 MSI Plessey UK Plessey China Post China Finance Telepen GS1 DataBar formerly RSS variants 2D PDF417 QR Code DataMatrix Han Xin Cod...

Page 6: ...4 Electrical Safety EN60950 1 Photobiological Safety EN62471 2008 Illumination 0 100 000 LUX ESD Protection 4 KV contact discharge 8 KV air discharge Drop Resistance Withstands multiple 2 0 m 6 6 ft drops to concrete Sealing IP50 ...

Page 7: ...ar 4 N Fm Code 128 1 K Cm UCC EAN 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V MSI Plessey 4 O Mm UK Plessey 1 U Mm China Post 11 2 T Im China Finance 10 2 Y Telepen 1 P Em GS1 DataBar 16 2 R em GS1 DataBar Truncated3 16 2 R em GS1 DataBar Limited 16 2 R em GS1 DataBar Expanded 1 R em PDF417 p Lm DataMatrix d dm QR code q Qm Han Xin Code h X0 Aztec Code a zm MicroQR Code q Qm Note 1The se...

Page 8: ...4 2 Get started 2 1 Dimensions ...

Page 9: ...5 2 2 Parts of the scanner Figure 2 1 LED Beeper Scan window Trigger Release hole of the cable Cable interface port ...

Page 10: ...e connector pin outs descriptions Pin RS232 USB 1 Power 5V Power 5V 2 Reserved Reserved 3 Ground Ground 4 3 3V for interface auto selection purpose Ground for interface auto selection purpose 5 TxD Reserved 6 RxD Reserved 7 Reserved Reserved 8 Reserved Reserved 9 CTS D 10 RTS D Note Voltage level of all RS232 Pin outs RxD TxD CTS and RTS is 0V for logic low and 3 3V for logic high 0 Pin 1 Figure 2...

Page 11: ...USB interface cable to the bottom of the scanner 2 Plug the series A connector in the USB host or an available portof the terminal 3 Windows will automatically detect the USBdevice Figure 2 3 2 4 2 Installation RS 232 1 Connect the RS 232 interface cable to the bottom of thescanner 2 Connect the other end of the interface cable to the serial port on the host Tighten the two screws to secure the co...

Page 12: ...tighten the screws 2 Bend the neck to the desired position forscanning 3 Screw mounting Screw one 10 wood screw into each screw mount hole until the base of the stand is secured 4 Tape mounting Peel the paper liner off one side of each piece of tape and place the sticky surface over each of the three rectangular tape holders Peel the paper liner off the exposed sides of each piece of tape and pres...

Page 13: ...ng Figure 2 6 The scanner offers 2 methods to enable disable Auto detection quickly Method 1 Scan the barcode EN AutoDete on the stand to enable Auto detection Scan the barcode DIS AutoDete on the stand to disable Auto detection Note The Scanning mode will switch to momentary See Figure 2 7 Method 2 Scan the barcode SWAM to enable Auto detection Scan the barcode SWLM to disable Auto detection Note...

Page 14: ...an setting Scan the appropriate e g 0101D00 according to the user s demand Example To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step 1 Scan the barcode e g 0101M according to the user s demand Step 2 To the right of the option barcode the necessary alphanumeric inputs are listed Scan two alphanumeric entries from barcode to or to F refer to 10 Configura...

Page 15: ...othervalues Example Set 0401 03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 2 Notes of making QR code barcode The model is chosen as M2 Other requirements e g ECC level Start mode etc are not specified Other notes The contents of a QR code barcode can include several same Option barcode index associated with same or different Al...

Page 16: ...tart barcode scanning following the setting of Scan mode If the scanner is in the mode of Auto detection the scanner will have a single scan then returns to Auto detection mode 2 Stop command 0x50 P If the Scan mode is set as Alternate continue or Continue and the scanner received the above command it will stop barcode scanning and act as in an idle mode 3 Restart command 0x35 R Once the scanner r...

Page 17: ...bleprovidedbythemanufacturerwillworkforaspecificinterface Interface selection Auto detection By setting this function the scanner will automatically detect the RS 232 interface or USB interface for user Multiple scan setting Single scan setting Option barcode Option Alpha entry Interface selection Auto detection RS 232 USB 00 RS 232 02 USB 03 ...

Page 18: ...e is no replied CTS signal from the host computer after the timeout duration the scanner will issue an error indication By setting Host idle Low RTS or Host idle High RTS the scanner can be set to match the Serial Host RTS line XON XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character ACK NAK After transmitting data the scanner expects either an ACK ...

Page 19: ...andard 00 OPOS JPOS 01 Flow control None 00 RTS CTS Host idle Low RTS 01 RTS CTS Host idle High RTS 02 XON XOFF 03 ACK NAK 04 Inter character delay 0 ms 00 5 ms 01 10 ms 02 20 ms 03 40 ms 04 80 ms 05 Response delay 00 99 100 ms 00 99 00 Baud rate 300 00 600 01 1200 02 2400 03 4800 04 9600 05 ...

Page 20: ...ultiple scan setting Single scan setting Option barcode Option Alpha entry 19200 06 38400 07 57600 08 115200 09 Parity bit None 00 Odd 01 Even 02 Data bit 8 bits 00 7 bits 01 Stop bit One bit 00 Two bits 01 ...

Page 21: ...nected to a POS terminal which may be necessary to install the OPOS JPOS driver to be compatible with the manufacturer s scanner The OPOS JPOS driver is provided by the scanner manufacturer please contact the scanner manufacturer for the instruction Keyboard layout The scanner supports different national keyboard layouts Commonly an appropriate encoding system must be selected Please refer to Char...

Page 22: ...ac 01 USB virtual COM 02 Simple COM Port Emulation 03 HID for OPOS JPOS 04 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russian 11 Czech 12 Character encoding system Refer to 3 7 Scan mode some global settings Inter character delay 0 ms 00 5 ms 01 ...

Page 23: ...19 Multiple scan setting Single scan setting Option barcode Option Alpha entry 10 ms 02 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 ...

Page 24: ...canner stops scanning when no code is successful decoded after the elapsed Once the scanner stops scanning the present object must be removed to Working mode of Auto detection In stand The scanner must be placed in the stand to enable Auto detection When the scanner is not will be Momentary Note This function is only valid when the is is always enabled regardless of the placement of the scanner No...

Page 25: ...rintable character only If this option is selected the scanner will output the printable characters only i e in ASCII from 20H to 7EH Alphanumeric character only If this option is selected the scanner will output the alphanumeric characters only i e A Z a z 0 9 Decoder optimization If it is enabled the scanner will optimize the decoder with error correction This function is not effective for all t...

Page 26: ... delay Sleep mode If it is enabled the scanner will go to sleep when no code is successful decoded after the elapsed Sleep mode delay When no code is successful decoded beyond this time the scanner will go to sleep ...

Page 27: ...y 01 Alternate continue 02 Continue 03 Good read on 04 Auto detection Good read on 06 Auto detection Good read off 07 Working mode of Auto detection In stand 00 Always ON 01 Auto detection sensitivity 5 00 10 01 15 02 20 03 25 04 30 05 35 06 40 07 45 08 50 09 Standby duration 4 seconds 00 8 seconds 01 16 seconds 02 ...

Page 28: ...s 06 2 minutes 07 5 minutes 08 7 minutes 09 10 minutes 10 15 minutes 11 20 minutes 12 30 minutes 13 45 minutes 14 1 hour 15 Same barcode delay time for 1D symbol 00 FF16 50 ms 00 FF16 00 08 Same barcode delay time for 2D symbol 00 FF16 50 ms 00 FF16 00 08 Double confirm 00 09 00 no 00 09 00 Global max code length for 04 99 04 99 ...

Page 29: ...mendment Disable 00 Enable 01 Character output restraint None 00 Printable character only 01 Alphanumeric character only 02 Decoder optimization Disable 00 Enable 01 Data output delay in continue scan mode 00 99 100 ms FF Never 00 FF16 00 Character encoding system ASCII 00 UTF 8 01 Windows 1251 02 Complete data output before next decode attempt Disable 00 Enable 01 Sleep mode Disable 00 Enable 01 ...

Page 30: ...ion barcode Option Alpha entry Sleep mode delay 1 second 00 5 seconds 01 10 seconds 02 30 seconds 03 60 seconds 1 minute 04 300 seconds 5 minutes 05 600 seconds 10 minutes 06 1800 seconds 30 minutes 07 3600 seconds 1 hour 08 10800 seconds 3 hours 09 ...

Page 31: ...icate a good barcode reading and its beep tone duration is adjustable Beep tone duration This parameter can be adjusted for a good reading upon favorite usage Volume of beeper This parameter can be adjusted for different level of the volume of the beeper Multiple scan setting Single scan setting Option barcode Option Alpha entry Power on alert Disable 00 Enable 01 LED indication Disable 00 Enable ...

Page 32: ...s option is enabled the scanner will project the aiming pattern during the code capture Level of decode illumination This parameter can be adjusted for different level of decode illumination Illumination mode of Auto detection Always off Illumination LED will be always turned off Enable illumination in low light conditions In low light conditions the scanner will turn on illumination LED automatic...

Page 33: ...On 01 Flashing 02 Always On when reading 03 Decode aiming pattern Always Off 00 Always On 01 On before reading 02 On when reading 03 Level of decode illumination Disable decode illumination 00 Low 01 Middle 02 High 03 Illumination mode of Auto detection Always off 00 Enable illumination in low light conditions 01 Always on 02 ...

Page 34: ... setting Enable the scanner reads only the barcode centered by the aimer in vertical direction However the scanner will read either one of two barcodes which are positioned horizontally See example below Mobile screen read By setting enable the scanner can read barcodes on a mobile screen better However this will slow the reading speed of normal barcodes a little bit ...

Page 35: ...bol setting 00 All 1D OFF 01 2D symbols read Follow respective 2D symbol setting 00 All 2D OFF 01 All 2D ON 02 Only PDF417 ON 03 Only QR code ON 04 Only Data Matrix ON 05 Only MaxiCode ON 06 Only Aztec Code ON 07 Only Han Xin Code ON 08 Vertical centering read Disable 00 Enable 01 Mobile screen read Disable 00 Enable 01 ...

Page 36: ...maintaining the distance of about 15cm between the scan window of the scanner and this paper After a few seconds the scanner will give three short beeps to indicate a successful calibration or a long beep to indicate a failed calibration 3 If the calibration is failed in step 2 please repeat the steps 1 2 If it is not succeed after a multiple times of calibration please contact your local dealer o...

Page 37: ...efer to settings of 3 7 Scan mode some global Supplement digits The Supplement digits barcode is the supplemental 2 or 5 characters Format Truncation Expansion Truncate leading zeros The leading 0 digits of UPC A data characters can be truncated when the feature is enabled Expand to EAN 13 It extends to 13 digits with a 0 leading digit when the feature is enabled Truncate system character The syst...

Page 38: ...n Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Truncate leading zeros 01 Expand to EAN 13 02 Truncate system character 03 Add country code 04 ...

Page 39: ...digits Format of 3 11 UPC A System character 0 Data digits 6 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros Refer to of 3 11 UPC A Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is set to be enabled Example Barcode 0123654 Output 0012360000057 Expand to UPC A It extends to 12 digits when the feature is set to be enabled Truncate sys...

Page 40: ...n Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Truncate leading zeros 01 Expand to EAN 13 02 Expand to UPC A 03 Truncate system character 04 ...

Page 41: ...roup selection Refer to Supplement digits Format of 3 11 UPC A System character 1 Data digits 5 digits Check digit Supplement digits 2 or 5 Truncation Expansion Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is set to be enabled Expand to UPC A It extends to 12 digits when the feature is set to be enabled Truncate system character The system character 1 of UPC E1 data can ...

Page 42: ...t verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Expand to EAN 13 02 Expand to UPC A 03 Truncate system character 04 ...

Page 43: ...ection Refer to Supplement digits Format of 3 11 UPC A of 3 11 UPC A Data digits 12 digits Check digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Book Number or Bookland EAN and ISSN International Standard Serial Number are two kinds of barcode for books and magazines The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN 13 s...

Page 44: ...rification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 EAN 13 code ID setting 00 FF16 00 FF16 ASCII A Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 ISBN ISSN conversion Disable 00 Enable 01 ISBN ISSN code ID setting 00 FF16 ASCII 00 FF16 B ...

Page 45: ... the data digits Check digit trans By setting Enable check digit will be transmitted CodeIDsetting Referto Insertion group selection Refer to Supplement digits Format of 3 11 UPC A Truncation Expansion Refer to Code ID setting of 3 11 UPC A Insertion group selection Data digits 7 digits Check digit Supplement Digits 2 or 5 Truncation Expansion of 3 11 UPC A ...

Page 46: ...1 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Truncation Expansion None 00 Truncate leading zero 01 Expand to EAN 13 02 ...

Page 47: ...length barcodedecoded Code ID setting Refer to Insertion group selection Refer to of3 11UPC A Start End transmission The start and end characters of Code 39 are s You can transmit all data digits including two s as data character By setting Enable can be recognized as data character Convert Code 39 to Code 32 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry Note that Cod...

Page 48: ...ble 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 44 00 44 00 Format Standard 00 Full ASCII 01 Start End transmission Disable 00 Enable 01 as data character Disable 00 Enable 01 Convert Code 39 to Code 32 Disable 00 ...

Page 49: ...ing Single scan setting Option barcode Option Alpha entry Enable 01 Code 32 Prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01 Trioptic Code 39 Start End transmission Disable 00 Enable 01 ...

Page 50: ...are two optional check digit algorithms the specified Uniform Symbol Specification USS and the Optical Product Code Council OPCC Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Code ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Max Min code length Code ID setting of 3 11 UPC A Insertion group selection ...

Page 51: ...ha entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID setting 00 FF16 ASCII 00 FF16 I Insert group selection 00 44 00 44 00 ...

Page 52: ...efer to Code ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID setting 00 FF16 ASCII 00 FF16 H Insert group selection 00 44 00 44 00 ...

Page 53: ...de ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID setting 00 FF16 ASCII 00 FF16 X Insert group sel...

Page 54: ...of Start End pattern you may select one pair to match your application Start End transmission Refer to Start End transmission of 3 16 Code 39 Start End character equality By setting Enable the start and end character of a Codabar barcode must be the same Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable ...

Page 55: ...etting Option barcode Option Alpha entry Insert group selection 00 44 00 44 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn e 03 Start End transmission Disable 00 Enable 01 Start End character equality Disable 00 Enable 01 ...

Page 56: ...llbetransmitted Max Min code length Refer to Code ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Truncate leading zeros The leading 0 digits of Code 128 barcode characters can be truncated when the feature is enabled Data digits variable Check digit optional Max Min code length Code ID setting of 3 11 UPC A Insertion group selection ...

Page 57: ...Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert group selection 00 44 00 44 00 Truncate leading zeros Disable 00 All leading 0 s 01 Only the first 0 02 ...

Page 58: ...t optional Check digit verification The check digit is made as the sum module 103 of all data digits Checkdigittransmission BysettingEnable checkdigitwillbetransmitted Max Min code length Refer to Code ID setting Refer to Insertion group selection Refer to Truncate leading zeros Refer to of 3 16 Code 39 of 3 11 UPC A of 3 11 UPC A of 3 23 Code 128 ...

Page 59: ...Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert group selection 00 44 00 44 00 Truncate leading zeros Disable 00 All leading 0 s 01 Only the first 0 02 ...

Page 60: ...r to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert group selection 00 44 00 ...

Page 61: ... ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 L Insert group selec...

Page 62: ...le 11 of all data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Code ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Max Min code length Code ID setting of 3 11 UPC A Insertion group selection ...

Page 63: ...ad Disable 00 Enable 01 Check digit verification Disable 00 One digit 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID setting 00 FF16 ASCII 00 FF16 V Insert group selection 00 44 00 44 00 ...

Page 64: ... Mod 10 11 The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Code ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Max Min code length Cod...

Page 65: ...00 Enable 01 Check digit verification Disable 00 1 digit Mod 10 01 2 digit Mod 10 10 02 2 digit Mod 10 11 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID setting 00 FF16 ASCII 00 FF16 O Insert group selection 00 44 00 44 00 ...

Page 66: ... Max Min code length Refer to Code ID setting Refer to Insertion group selection Refer to of 3 16 Code 39 of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ...

Page 67: ...o of 3 16 Code 39 The code length of China Post of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Max code length 00 99 00 99 11 Min code length 00 99 00 99 11 Code ID setting 00 FF16 ASCII 00 FF16 T Insert group selection 00 44 00 44 00 Code ID setting of 3 11 UPC A Insertion group selection ...

Page 68: ...00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 00 FF16 P Insertion group selection 00 44 00 44 00 Encode character set type Alphanumeric 00 Numeric 01 ...

Page 69: ... String transmission Cm will be identified as UPC A or EAN 13 Barcode beginning with a single zero as the first digit has the leading 010 stripped and the barcode reported as EAN 13 Barcode beginning with two or more zeros but not six zeros has the leading 0100 stripped and the barcode reported as UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Ena...

Page 70: ... of 3 31 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 R Insert group selection 00 44 00 44 00 Conversion None 00 UCC EAN 128 01 UPC A or EAN 13 02 16 Data digits Code ID setting of 3 11 UPC A Insertion group selection ...

Page 71: ... Cm will be identified as AIM Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 R Insert group selection 00 44 00 44 00 Conversion None 00 UCC EAN 128 01 Data characters variable Code ID setting of 3 11 UPC A Insertion group selection of 3 1 ...

Page 72: ...71 3 32 PDF417 Read Format Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Data characters variable ...

Page 73: ...72 3 33 QR Code Read Format Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Data characters variable ...

Page 74: ...73 3 34 Data Matrix Read Format Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Data characters variable ...

Page 75: ...de Note The support for this feature is available with customized firmware version Read Format Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Data digits variable ...

Page 76: ...75 3 36 Aztec Code Read Format Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Data digits variable ...

Page 77: ...ode Note The support for this feature is available with customized firmware version Read Format Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Data digits variable ...

Page 78: ...Example Add a symbol of as a prefix for all symbols Steps 1 Scan the option barcode of Prefix string setting 2 Use the ASCII table to find the value of 24 3 Scan 4 Scan and 4 from the barcode on the last page barcode Scanning steps Scan the following barcodes in order Insert G1 G2 G3 G4 string setting The scanner offers 4 positions and 4 character strings to insert among the symbol Example Set G1 ...

Page 79: ... data 1 2 3 4 5 6 Steps scan the following data in order Testing barcode Truncate ending G6 string setting Bysetting a defined ending character or string can be truncated Also a single character can be un defined Repeat of a G6 character setting While G5 is set as a single defined un defined character G6 can also be set to be repeated This setting is ignored when the truncate number is more than t...

Page 80: ... number of characters to replace is11 Example Replace all the A character in a data string with B character replace C with D replace E with F Original code data 1 2 3 A 4 C 5 6 E 7 8 Output code data 1 2 3 B 4 D 5 6 F 7 8 Steps scan the following barcodes in order The ASCII value for A is 41 for B is 42 for C is 43 for D is 44 for E is 45 and for F is 46 Testing barcode ...

Page 81: ...0 Postamble string setting 0 22 characters 00 FF16 None 00 Insert G1 string setting 0 22 characters 00 FF16 None 00 Insert G2 string setting 0 22 characters 00 FF16 None 00 Insert G3 string setting 0 22 characters 00 FF16 None 00 Insert G4 string setting 0 22 characters 00 FF16 None 00 FN1 substitution string setting 0 4 characters 00 FF16 SP 20 Truncate leading G5 string setting A un defined char...

Page 82: ...ned times All FF Truncate ending G6 string setting A un defined character 00 1 22 defined characters 01 7F16 0 30 Repeat of a G6 character setting Once 01 Defined times 01 22 Un defined times All FF Single character C1 replacement 0000 0000 0000 FFFF 16 Single character C2 replacement 0000 0000 0000 FFFF 16 Multiple characters C3 replacement 0000 ...

Page 83: ...e insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement Multiple scan setting Single scan setting Option barcode Option Alpha entry Insert G1 string position 00 99 00 99 00 Insert G2 string position 00 99 00 99 00 Insert G3 string position 00 99 00 99 00 Insert G4 string...

Page 84: ...be transmitted before the code data when Enable is selected The length is represented by a number with twodigits Case conversion The characters within code data or the whole output string can be set in either upper case or lower case FN1 substitution transmission The scanner supports a FN1 substitution feature for USB and RS 232 interface The replacement string of FN1 can be chosen by user see 3 4...

Page 85: ...ansmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Proprietary ID 01 AIM ID 02 Code length transmission Disable 00 Enable 01 Case conversion Disable 00 Upper data only 01 Lower data only 02 Upper whole string 03 Lower whole string 04 FN1 substitution transmission Disable 00 ...

Page 86: ...arcode Option Alpha entry USB 01 RS 232 02 USB RS 232 03 All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characters only All 99 01 99 Transmit the last N data characters only All 99 01 99 ...

Page 87: ...canning accuracy 1 Do not allow any abrasive material to touch thewindow 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened withwater 4 Do not spray water or other cleaning liquids directly into thewindow 5 Use a piece of soft and dry cloth when cleaning thescanner ...

Page 88: ...code is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select Code128 then select CODE A type and input DC1 as data Up Down Left Right Page Up Page Down Backspace Tab Home End Enter Insert Delete F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Esc F11 F12 ...

Page 89: ...F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only Example ASCII A 41 H L 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o DE...

Page 90: ...89 7 Test barcode UPC A UPC E UPC E1 Default setting Disable EAN 13 ISBN ISSN EAN 8 Code 39 Interleaved 2 of 5 Industrial 2 of 5 Default setting Disable Matrix 2 of 5 ...

Page 91: ...28 UCC EAN 128 ISBT 128 Code 93 Code 11 Defaultsetting Disable MSI Plessey Default setting Disable UK Plessey Default setting Disable China Post GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1 DataBar Expanded ...

Page 92: ...xyz QRcode 1234567890ABCD XYZ Data Matrix 123890abc mdo Aztec Code Default setting Disable 12345678901234567890 Han Xin Code Default setting Disable 1234567890Hanxin Micro QR Code Default setting Disable 0123456789MicroQR ...

Page 93: ...bleAuto detection Enable Auto detection If you wish to enable Auto detection scan the barcode above Disable Auto detection If you wish to disable Auto detection scan the barcode above Note The momentary will switch to Scanning mode ...

Page 94: ...firmware version WARNING Default value initialization If you wish to return the scanner to all the factory default settings scan the barcode above Firmware version list If you wish to display the firmware version scan the barcode above ...

Page 95: ...94 10 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below ...