Page 1: ...Contents 1 User Manual Walk Through Metal Detector ZK D1065S Version 1 2 Date December 2019...

Page 2: ...on 2 Installation Environment 3 Performance and Features 5 Application 7 Parts 8 Installation 9 Control Panel 11 Detection Zones 12 Operation 13 Detection Adjustment 16 Brief Maintenance 18 Technical...

Page 3: ...ouch the detector during security checking to avoid false alarm 3 Make sure there s no big metal object or strong magnetic field around the detector within 2 meters 4 Detector probe mustn t install in...

Page 4: ...to check the metal items hidden on the body When the passengers pass through the device if they carried metals more than preset parameters value the device would immediately alarms and display alarm l...

Page 5: ...device about 2 meters to avoid false alarm 3 Floor Vibration The floor should be flat and fixed to avoid false alarm after installation by the movement of people walking or moving and shaking of metal...

Page 6: ...rmer Ac Power Lines Thyristor Control Circuit High Power Switching Power Supply Inverter Welder Engine Motor etc 5 Side By Side Using When installing the devices side by side the distance between two...

Page 7: ...detection zone has 100 sensitivity levels 0 99 Preset metal size you can exclude the coins keys jewelry belt buckle etc Digital Pulse Technology digital signal processing and filtering system has exc...

Page 8: ...ot only can fixed the device but also waterproof Waterproof using PVC synthetic material special technology waterproof fireproof shockproof Easy to install the system is integrated design just 15 minu...

Page 9: ...ll exhibition business event celebration stadium and other important public places 4 Important industrial and mining enterprises such as hardware electronics jewelry mint to prevent the loss of precio...

Page 10: ...8 ZK D1065S User Manual Parts 1 Control Unit Case 2 Alarm zone LED 3 Built in Probe 4 Infrared Sensors 5 Waterproof Foot Cover 6 Power Line Interface 1 2 4 5 3 6...

Page 11: ...nit and door panel 2 Put the control unit case and door panels as above picture shown and then connect the left and right door panel with the control unit case by bolts Tightening screws 3 Probe line...

Page 12: ...10 ZK D1065S User Manual 4 Lift the walk through metal detector to the vertical position and move to the assigned position 5 Plug power cable...

Page 13: ...the tens digit when setting the zone sensitivity level If press SETUP for 5 seconds you can adjust the frequency From frequency 1 to frequency 12 is optional 3 SELECT choose each program and increase...

Page 14: ...eans whole sensitivity and the sensitivity levels higher the sensitivity higher If the metal reaches or exceeds preset value the red LED alarm If there are multiple alarm targets the LED light of each...

Page 15: ...ECT to select zone 2 7 to adjust corresponding zone sensitivity especially zone 7 is whole sensitivity xx is sensitivity level press SETUP to adjust tens digit press ENTER to adjust unit digit the big...

Page 16: ...ark xx means working frequency press SETUP to select frequency the scope for working frequency is 1 12 can be selected Startup Shutdown Press RESET five seconds to startup or shutdown Password input F...

Page 17: ...ELECT Input password Display Press SETUP to shift ENTER ENTER Change password Remark If you forgot the password you can input the universal password 88888 to reset a new password 00000 0 000 Increase...

Page 18: ...buckle shoes and so on according to the following steps to adjust a Choose a small metal as the sample such as keys b Increasing the sensitivity so that when the tester carry the sample and pass throu...

Page 19: ...rried metal objects such as keys mobile phone watch coins etc place on the side of security chute or a table and pick it up after security checking c Passengers should line up one by one to pass the d...

Page 20: ...e OK please replace the Infrared sensor 2 False alarm a After installation if the device gives false alarms frequently firstly check the installation environment Make sure there is no movable or stati...

Page 21: ...ltage 100 240V 50 60Hz Power 12W Gross weight 70KG Working temperature 20 50 Sensitivity 100 steps adjustable Alarm Visible and audible alarm Inner Dimensions 1990mm High x 700mm Wide x 578mm Deep Ext...

Page 22: ...Packing List Package should contain the following items 1 L side panel 1set 2 R side panel 1set 3 Control Unit 1pc 4 User manual 1pc 5 Power cord 1pc 6 Threaded bolt 8pcs 7 Hexagon wrench 1pcs 8 Prob...

Page 23: ...d will be regarded as invalid if it has not been filled in details three guarantees and acknowledgment of receipt Please confirm whether the data filled in the three guarantees and acknowledgement of...

Page 24: ...22 ZK D1065S User Manual Date of Maintenance Record of Maintenance Maintainer...