The default configuration of the Standalone Terminal is as follows: 

Demo Using Instructions: 

 

Connect the USB port of the Standalone Terminal to the USB port of the computer. 

 

The power adapter is recommended to use the DC12V/3A specification. Power supply to the 
Standalone Terminal and the buzzer sounds once. 

 

In the computer to open Demo, click ’Connect’, on the right side of the middle will show 
‘Connect Successful’ , and machine and demo connection success. 

 

Wiegand Interval Time: Sets the time interval between adjacent wiegand data. 

 

Reader Indicate: Set whether the buzzer rings when the machine is on the electricity and 
brush the card. 

 

Work Mode: Set the working mode of the machine, and including always read mode, trigger 
mode. Under trigger mode, time of reading card can be set when it is triggered once. 

 

RF Setting: Set the RF parameters of the machine, including power, spectrum. Power range is 

Work Mode 

Always Read 

Read Tag Interval Time 

0s (Default) 

Wiegand Out Setting 

wiegand 26; Forward Output; 9th Start Byte(Default);   

Wiegand Interval Time 

2s (Default) 

Output Power 

18dBm~26dBm 

Working Frequency 

902MHz ~928MHz (American Standard);   
865MHz ~ 868MHz (European standard) 

Summary of Contents for U1000E

Page 1: ...1 User Manual UHF RFID Standalone Terminal Version 1 0 Date December 2017...

Page 2: ...rize 1 2 UHF RFID Standalone Terminal 1 3 Parameters Specifications 2 4 Safety Precautions 3 5 Modifying Setting via Demo 3 6 Access to Software 5 6 1 Access to ZKAccess 5 6 2 Access to ZKBioSecurity...

Page 3: ...e parking lot and access control system Meanwhile the utility model has the advantages of stable reading performance good consistency low working current and temperature long service life and small ex...

Page 4: ...Wiegand Signal Wiegand input output Working Frequency F 902Mhz 928MHz E 865MHz 868MHz Support Card Tag1 Tag2 Tag3 Tag4 DF01Card DF02 Card UHF Interface Protocol EPC global UHFClass1Gen2 ISO18000 6c A...

Page 5: ...recommended to use DC12V 3A power supply 2 Please wire according to the cable definition 5 Modifying Setting via Demo 1 USB Connection 2 Software Introduction Our company provides Demo used to set the...

Page 6: ...ets the time interval between adjacent wiegand data Reader Indicate Set whether the buzzer rings when the machine is on the electricity and brush the card Work Mode Set the working mode of the machine...

Page 7: ...ard is read within the scope of the card to the card is left out of the scope of the card to read the second time card 6 Access to Software RJ45 Connection Connect the RJ45 port of the Standalone Term...

Page 8: ...the Standalone Terminal may conflict with the IP of a device on the Internet You can modify its IP address Click Modify IP Address behind the device and a dialog box will open Enter the new IP address...

Page 9: ...All Data and click OK to complete synchronization The system will synchronize the data to the device including door information access control levels personnel information access control time zones a...

Page 10: ...y recognition mode long distance access control gets rid of the passive recognition of the shackles really realize the Hand Free model Remote sensing automatic reading card automatic identification wi...

Page 11: ...r tag4 pasted on the interior windshield of car and parking barrier When the car pulls up the range of the U2000 Standalone Terminal the authorized tag mounted on car will be identified then reading i...

Page 12: ...le environment the Standalone Terminal may fail to read the card due to the overlarge reading angle You can install an additional Standalone Terminal at the corner to solve the problem For such terrai...

Page 13: ...KTeco Logo is a registered trademark of ZKTeco or a related company All other product and company names mentioned are used for ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhe...

Reviews: