background image

The Adjustable Tension Spring is used to adjust the tripod turnstile's elasticity and return speed. You can rotate it in 
clockwise direction to enhance and in anticlockwise direction to weaken the elasticity and return speed of the tripod 
turnstile. See Figure 5-2. 

Figure 5-3 shows the mechanical and electrical structure of this equipment. 

 

 

 

 

                                                              

 

   

 

 

 

 

 

 

 

Figure 5-2                                        Figure 5-3 

 

6. Troubleshooting 
 

Symptom 

Troubleshooting 

The indicator is not lighted when the 
equipment is powered on. 

It may be caused by the power supply or circuit.   
Check whether the connection cable and power cable between are 
damaged, or the wiring is loose.   

The arms of the tripod turnstile cannot be 
lifted manually after the equipment is 
powered on. 

It may be caused by the problem of relative components or drop-arm 
solenoid. 

1. Check whether the stop base and turn plate withstands each other, as 

shown in Figure 6-1. 

2. Check whether the drop-arm  solenoid  is operating, and check the 

work status of the solenoid, as shown in Figure 6-2.   

The tripod turnstile does not open after 
authentication. 

It may be caused by lack of permission or a circuit problem. 

1. Check whether the user has the permission to open the turnstile. 
2. Use a multimeter  to check whether the NO and COM ports of the 

access control system has a relay signal output. 

3.  Short-circuit the ports "K1, GND" and "K2, GND", if the turnstile is 

successfully opened, it would be the  problem  of  controller. In this 
case, please refer to 

Attachment 2 Connection Diagram of Control 

board and Access Control Panel

 to check the cable connection of the 

controller. 

Drop-arm Solenoid 

Position Sensor 

Lock Rod 

Adjustable Tension Spring 

Turnstile-opening 

Solenoid 

Lock Rod 

Metal Shrapnel      Tri-lobed Wheel 

Turnstile-opening 

Solenoid 

Summary of Contents for TS1200 Series

Page 1: ...TS1200 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Page 2: ...Indoor and Outdoor shelter Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 55kg Operating Humidity 5 85 Gross Weight 63kg Flow Rate 25 30 passages minute Dimension mm Figure 1 L 600 W 330...

Page 3: ...nstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 4 4 Check whether the tripod turnstile and the LED indicators work properly If there is any problem please contact...

Page 4: ...is millimeter Power supply and communication wire should go through the inlet Cable protection covers are suggested to use if it is surface mounted Warning The tripod turnstile must be connected to t...

Page 5: ...he gaskets provided Note that all the six expansion bolts must be installed properly as shown in Figure 3 4 Figure 3 4 3 Put the turnstile on the mounting plate and tighten the screws Apply screw secu...

Page 6: ...ED screen and display the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Right J4 Left Indicator To connect a LED screen and indicate w...

Page 7: ...Signal Input otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar...

Page 8: ...ard each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enabled or disabled t...

Page 9: ...enter of the arm is 80kg and at the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole e...

Page 10: ...or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating and check the work status of the solen...

Page 11: ...any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people con...

Page 12: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Page 13: ...tion Diagram of Control board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to t...

Reviews: