Verification Mode
You can set the verification mode as
Allow verification in Channel
, or
No verification
allowed in Channel.
Memory Function
When more than two legal access signals are given at the same time (including the same
direction and the opposite direction), the system will remember all pass requests and complete
each pass in turn.
Stay Duration Time
You can set the duration of stay in the channel after successful verification, with a valid value of
0-60 seconds.
Open Duration Time
Open duration time refers to the period of time from opening to closing once the turnstile
receives an open signal. You can set the unattended time or Open Duration Time, with a valid
value of 2 to 60 seconds.
Gate Closing Delay Time
After pedestrian passes through the last infrared sensor, the gates will keep opening the time
what you set, then close immediately. You can set the Gate Closing Delay Time, with a valid
value of 0-60 seconds.
Fire Mode
According to the external fire equipment, select the corresponding type of trigger mode. You
can set Fire Mode as
Entry Opening
,
Exit Opening
or
Disabled
.
Volume Setting
You can adjust the volume of the device, with a valid value of 0-100.
Alarm Tone Setting
You can enable or disable the alarm tone.
In/Out Exchange
You can switch the direction of the entrance and exit.