It is recommended that the swing barrier turnstile be installed on a horizontal solid platform with
50 mm to 100 mm in height, the horizontal angle must not be greater than ±0.7°.
1.
2.
3.
After installation, check if the connection is done correctly at the connecting points of the ground
wire, at the connector assemblies and wiring points of the circuits, as well as at each movable part
of the swing barrier turnstile. Any loose nuts, screws and other fasteners should be tightened in
time to avoid any failures caused by long-time operations.
4.
1
1 Installation Requirements
The installation position of the swing barrier turnstile depends on its size. A distance of 100mm between
the swing barrier turnstile and the wall needs to be reserved for ease of opening the top cover of the
machine to perform maintenance and adjustment. The reference figure is shown below:
2 Installation Position
Figure 2-1 SBT2000S Series Dual-lane
Make sure the ground wire of the system is reliably connected to avoid personal injuries or other
accidents.
It is also recommended that the swing barrier turnstile should not be used in the corrosive
environment.
2274.02
2174.02
900
592
800
Summary of Contents for SBT2000S