RevFace15
User Manual
P a g e
| 71
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
Normal Close Time
Period
It is the scheduled time-period for “Normal Close” mode so that the door is
always close during this period.
Normal Open Time
Period
It is the scheduled time-period for “Normal Open” mode so that the door is
always open during this period.
Auxiliary Input
Configuration
Sets the door unlock time period and auxiliary output type of the auxiliary
terminal device.
Auxiliary output types include None, Trigger door open,
Trigger Alarm, Trigger door open and Alarm.
Verify Mode by
RS485
The verification mode is used when the device is used either as a host or
slave.
The supported verification mode includes Card only, and Card + Password.
Speaker Alarm
It transmits a sound alarm or disassembly alarm from the local. When the
door is closed or the verification is successful, the system cancels the alarm
from the local.
Valid Holidays
To set if
Normal Close Time Period
or
Normal Open Time Period
settings
are valid in set holiday time period. Choose [
ON
] to enable the set
NC
or
NO
time period in holiday.
Speaker Alarm
It transmits a sound alarm or disassembly alarm from the local. When the
door is closed or the verification is successful, the system cancels the alarm
from the local.
Reset Access Setting
The access control reset parameters include door lock delay, door sensor
delay, door sensor type, verification mode, door available time period, normal
open time period, master device, and alarm. However, erased access control
data in Data Mgt. is excluded.
Time Rule Setting and Time Schedule
11.2
Tap
Time Rule/Time Schedule
on the
Access Control
interface to configure the time settings.
The entire system can define up to 50 Time Periods.
Each time-period represents
10
Time Zones, i.e.,
1
week and
3
holidays, and each time zone is a
standard 24 hour period per day and the user can only verify within the valid time-period.
One can set a maximum of 3 time periods for every time zone. The relationship among these time-
periods is "
OR
". Thus, when the verification time falls in any one of these time-periods, the
verification is valid.
The Time Zone format of each time-period is
HH MM-HH MM
, which is accurate to minutes
according to the 24-hour clock.
Tap the grey box to search the required Time Zone and specify the required Time Zone number (maximum
up to 50 zones).