background image

10

Ethernet Connection

Connect the device and computer software over an Ethernet cable. An example is shown below:

 

: 192.168.1.201

Default IP address

: 255.255.255.0

 Subnet mask

 

: 192.168.1.130

IP address

: 255.255.255.0

 Subnet mask

Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment 
when connecting to ZKBioSecurity software.

Click on [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK].

9

Power Connection

12V

3A

DC

Recommended power supply

: 12V - 3A

To share the power with other devices, use a power supply with higher

 

current ratings

.

 

7

Summary of Contents for ProFace X

Page 1: ...Quick Start Guide ProFace X Version 1 0 Date May 2019...

Page 2: ...xit button Auxiliary input AUX AL AL NC COM NO BUT GND SEN GND Alarm Lock Sensor GND 12V Power GND INWD0 INWD1 Wiegand In Wiegand Out 12V GND WD0 WD1 Network interface RS232 RS485 12V 485B 485A GND TX...

Page 3: ...sticker to the wall and drill holes according to the mounting paper Fix the back plate on the wall using wall mounting screws Attach the device to the back plate Fasten the device to the back plate wi...

Page 4: ...r gate 1 2 Please thread the wire through the bracket before installation Drill a hole on the barrier gate insert the bracket into the hole and fix it with a nut Adjust the angle of the device 3 2 Dev...

Page 5: ...on Alarm Smoke detector Lock TCP IP Exit button Door sensor Reader PC 4 Door Sensor Exit Button Alarm Connection Door sensor Alarm power Alarm Detector power Smoke detector Exit button AUX AL AL NC CO...

Page 6: ...ected with NC and COM terminals Take NC Lock as an example below 1 Device not sharing power with the lock Normally Closed Lock DC12V DC12V 2 Device sharing power with the lock 12V GND FR107 FR107 Norm...

Page 7: ...GND 485 485 12V 485B 485A GND TXD1 RXD1 GND GND GND 12V 12V 485 reader 12V 485B 485A GND TXD1 RXD1 GND GND GND 12V 12V Note 485A and 485B can be connected to the barrier gate or the 485 reader but ca...

Page 8: ...address 255 255 255 0 Subnet mask Note In LAN IP addresses of the server PC and the device must be in the same network segment when connecting to ZKBioSecurity software Click on Comm Ethernet IP Addr...

Page 9: ...e For speci c operation please refer to the ZKBioSecurity User Manual When there is no super administrator set in the device click on to enter the menu After setting the super administrator the system...

Page 10: ...to set the server address and server port address and port number of the server after the software is installed If the device communicates with the server successfully the icon will be displayed in t...

Page 11: ...Copyright 2019 ZKTeco CO LTD All rights reserved ZK BuildingWuhe Road Gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394 www zkteco com...

Reviews: