ProFace X Series
User Manual
P a g e
| 62
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Access Control Options
To set the parameters of the control lock of the terminal and related devices.
Click
Access Control Options
on the Access Control interface.
Menu Name
Description
Gate Control Mode
Whether to turn on the gate control mode or not, when set to ON, this
interface will remove Door lock relay, Door sensor relay and Door sensor type
function.
Door Lock Delay (s)
The time duration that the device controls the electric lock to be unlocked.
The valid range is 1 to 10 seconds; 0 second represents disabling the function.
Door Sensor
Delay (s)
If the door is not closed and locked after opening for a certain duration (Door
Sensor Delay), an alarm will be triggered. The valid value of Door Sensor Delay
ranges from 1 to 255 seconds.
Door Sensor Type
There are three types: None, Normal Open, and Normal Closed. None means door
sensor is not in use; Normal Open means the door is always opened when
electricity is on; Normal Closed means the door is always closed when electricity is
on.
Verification Mode
The supported verification mode includes Password/Face, User ID only,
Password, Face only, and Face + Password.