Wiegand Output Connection

Controller

?

READER 1

BEEP GLED WD1 WD0 GND +12V

485B
485A
GND
TXD
RXD
GND
WD1
WD0

Wiegand Input Connection

BEEP
GLED
RLED
IWD1
IWD0
GND
12VOUT

1

7

Wiegand Reader

BEEP
GLED
RLED
DATA1
DATA0
GND
+12V

AC Adapter

DC 12V, 3A

GND
+12V

1

8

1

2

Summary of Contents for PA22

Page 1: ...A22 Version 1 0 Quick Start Guide Due to the regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual...

Page 2: ...Back Plate Reset Button Speaker USBSlot Front Back 2 4 Inch TFT LCD Keypad RFCardArea LEDIndicator Near infrared Palm Recognition Sensor Tamper switch Terminal Block Wiring Hole Mounting Hole 1 Devic...

Page 3: ...21 Device Dimensions Device Installation Attach the mounting template sticker to the wall and drill the holes according to the mounting paper Fix the back plate on the wall with using wall mounting sc...

Page 4: ...NC1 AL AL BEEP GLED RLED IWD1 IWD0 GND 12VOUT BEEP Green LED Red LED GND 12V Ethernet RS232 Lock Power Out Sensor Button Power In Auxiliary In Bell Alarm Wiegand Out Wiegand In 8 Pin Cable Connectors...

Page 5: ...4 Standalone Installation Alarm Bell Lock TCP IP Exit Button Door Sensor ALARM Wireless Router...

Page 6: ...DC 12V DC Adaptor Power Connection Without UPS GND 12V DC With UPS Optional 12V 10 at least 3000MA Use an AC adapter with a higher current ratings to share the power with other devices Recommended Pow...

Page 7: ...on Alarm Bell Connection Door Sensor Bell Alarm Exit Button 12V DC Adaptor 12V DC GND AUX GND BELL BELL SEN GND BUT NO1 COM1 NC1 AL AL 1 12 6 Connect the device and the software over an Ethernet cable...

Page 8: ...SEN GND BUT NO1 COM1 NC1 AL AL V V NC NO COM AC Adapter DC 12V 3A GND 12V 1 2 DO NOT REVERSE THE CONNECTION The system supports both Normally Opened Lock and Normally Closed Lock The NO Lock Normally...

Page 9: ...switches which are located on the back of RS485 fingerprint reader switches1 to 4 are for RS485 address switch 5 is reserved switch 6 is for noise reduction on long RS485 cable If the RS485 fingerpri...

Page 10: ...ntroller READER 1 BEEP GLED WD1 WD0 GND 12V 485B 485A GND TXD RXD GND WD1 WD0 Wiegand Input Connection BEEP GLED RLED IWD1 IWD0 GND 12VOUT 1 7 Wiegand Reader BEEP GLED RLED DATA1 DATA0 GND 12V AC Adap...

Page 11: ...m to access the menu For security reasons we highly recommend that you register a super administrator promptly Click M OK User Mgt New User to register a new user The options includes entering the Use...

Page 12: ...number of the server after the software is installed If the device communicates with the server successfully the icon will be displayed in the upper right corner of the standby interface Ethernet and...

Page 13: ...Access Control Setting 12 Click M OK Access Control to enter the access control management interface and set relevant parameters for the access control...

Page 14: ...endance Record 13 Click M OK Attendance Search Attendance Record to enter the records query interface input the user ID and select the time range The corresponding attendance logs will then be display...

Page 15: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2023 ZKTECO CO LTD All Rights Reserved...

Reviews: