InBio Pro Series Access Control Panels INSTALLATION guIDE

RS485 Connection 

1
2
4
8

16
32

Restore Factory Setting

RS485 Terminal Resistance 

                       Restore factory setting

1. 

If you forget the IP address of the InBio Pro panel or the device does not work 
normally, you can use the number 7 DIP switch to restore InBio Pro Panel to 
factory default settings. The parameters which gets reset are device IP address, 
communication password, gateway, and subnet mask.

2. 

The switch is OFF by default. When it is moved up and down for three times 
within 10 seconds and fi nally returned to OFF position, the factory settings will 
be restored after the access control panel is restarted.

To reset factory settings

Turn #7 switch ON and OFF

Repeat process 3 times

Figure 32

Figure 33

Summary of Contents for InBio Pro Series

Page 1: ...INSTALLATION GUIDE InBio Pro Series Access Control Panels Date June 2016 Version 1 2 INSTALLATION GUIDE ...

Page 2: ...2 InBio Pro Series Access Control Panels INSTALLATION guIDE What s in the Box 4 Diode 2 Screws Anchors 2 Screwdriver ...

Page 3: ...tions 15 Lock Connection 16 Connecting a Lock with External to Power Supply 16 Switching Dry Contact toWet Contact 17 Lock Connection 18 Normally Open Lock Powered From LockTerminal 18 Normally Closed Lock Powered From LockTerminal 18 Aux I O Connection 19 Aux Input Connection 19 Aux Output Connection 19 Ethernet Connection 20 LAN Connection 20 Direct connection 20 RS485 Connection 21 RS485 Connec...

Page 4: ...ries Access Control Panels INSTALLATION guIDE Optional accessories Wiegand Card Reader ZK4500 Enrollment reader RS485 Convertor RS485 Fingerprint Reader Prox Card CR20E Card Enroller K2 Exit Button InBio Pro Cabinet ...

Page 5: ... CRT TV monitor or speaker may damage the device Do not place the device next to heating equipment Be careful not to let liquid like water drinks or chemicals leak inside the device Do not let children touch the device without supervision Do not drop or damage the device Do not disassemble repair or alter the device Do not use the device for any other purpose than specified Clean the device often ...

Page 6: ...r Card Reader 1 Door Exit Button RS485 Fingerprint Reader 2 Door Card Reader 2 Door Exit Button 3 Door Card Reader 3 Door Exit Button 4 Door Card Reader 4 Door Exit Button 4 Lock Door Sensor 4 Aux Output RS485 Communication DIP Switches Ethernet Port Lock Power InBio Pro Power LINK LED ACT LED SD Card Slot Figure 1 ...

Page 7: ...85 TX RX Flashing Yellow Green LED indicates communication is in progress PC RS485 TX RX Flashing Yellow Green LED indicates communication is in progress Flashing POWER Red LED indicates the panel is powered on Flashing RUN Green LED indicates that panel is in normal working state Flashing CARD Yellow LED indicates that the card is read by the panel Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Fig...

Page 8: ...TALLATION guIDE Product Dimension Figure 10 InBio160Pro InBio260Pro InBio460Pro InBio Pro Metal Cabinet Figure 9 8 89 in 226 mm 7 125 in 181 mm 1 42 in 36 mm 4 17 in 106 mm 4 17 in 106 mm 4 17 in 106 mm 15 7 in 400 mm 13 in 330 mm 3 56 in 90 5 mm ...

Page 9: ...pply Backup Battery Mounting holes State Indicators Inserting Panel to Rail Mounting Rail We recommend drilling the mounting plate screws into solid wood i e stud beam If a stud beam cannot be found then use the supplied drywall plastic mollies anchors Step 1 Pass the cable through holes Step 2 Mount the Metal Cabinet Step 3 Insert the InBio Pro Panel as it shown Figure 11 Figure 12 1 2 ...

Page 10: ...ls INSTALLATION guIDE Wiring Legend Detector Ethernet Cable IR Sensor 485 Convertor Exit Button Floodlight Wiegand Card Reader Exit Button Normally Open Lock Normally Close Lock Wiegand Card Reader 12V DC Power Supply 12V DC Power Figure 13 ...

Page 11: ...1 InBio Pro Series Access Control Panels INSTALLATION guIDE PowerWiring Diagram Without Backup Battery With Backup Battery Switching Power Supply ground ground Switching Power Supply Figure 15 Figure 14 ...

Page 12: ...12 InBio Pro Series Access Control Panels INSTALLATION guIDE RS485 Fingerprint Reader Connection 12V DC 12V DC EThERNET 1 2 3 8 RS485 Fingerprint Reader Figure 16 ...

Page 13: ... Set the odd number for IN reader and the even number for OuT reader for eg For two readers for one door the RS485 address 1 is for IN reader RS485 address 2 is for OuT reader 3 If RS485 fingerprint reader is pow ered from InBio460Pro panel the length of wire should be less than 100 meters or 330 ft 4 The External RS485 interface can supply maximum 500mA current The RS485 fingerprint reader s star...

Page 14: ...14 InBio Pro Series Access Control Panels INSTALLATION guIDE Wiegand Connection Wiegand Card Reader Figure 18 Beeper green LED Wiegand D1 Wiegand D0 gND DC 6 14V ...

Page 15: ...5 InBio Pro Series Access Control Panels INSTALLATION guIDE REX Connections ZK ABK Exit Button K2 Exit Switch Separate Power Supply unused NO BuTTON COM gND 12V DC 12V DC Figure 19 Separate Power Supply ...

Page 16: ...o Pro Series Access Control Panels INSTALLATION guIDE Lock Connection Connecting a Lock with External to Power Supply Dry Contact FR107 Diode gND gND Sensor Sensor 12V DC Door Contact EThERNET Figure 20 Sensor ...

Page 17: ...rom the panel you must take the following steps 1 Take apart the cover of InBio460Pro Push the tab inward see figure 21 2 Select the appropriate lock relay and find its jumpers 3 Take off the jumpers and change to 4 Connect the lock as show in the diagram see figure 23 and 24 Back of InBio460Pro Select one Relay Default setting 1 2 3 4 Take off jumpers Jumpers Plug Jumpers 2 3 4 5 Figure 22 Figure 2...

Page 18: ...nection Normally Open Lock Powered From Lock Terminal Wet Contact Normally Closed Lock Powered From Lock Terminal Wet Contact 12V DC 12V DC 12V DC 12V DC gND gND FR107 Diode FR107 Diode gND gND EThERNET EThERNET Figure 23 Figure 24 16 or 18 AWG shielded cable recommended ...

Page 19: ...19 InBio Pro Series Access Control Panels INSTALLATION guIDE Aux I O Connection Aux Input Connection Aux Output Connection 12V DC 12V DC gND gND EThERNET Figure 26 Figure 25 EThERNET ...

Page 20: ...d Issuer ZK4500 Enrollment reader ZK4500 Enrollment reader CR20E Card Issuer EThERNET EThERNET 20 InBio Pro Series Access Control Panels INSTALLATION guIDE Ethernet Connection LAN Connection Important Notes 1 Both 10Base T and 100Base T are supported 2 This cable distance must be less than 330 ft 100m 3 For cable length of more than 330 ft 100m use huB to amplify the signal Figure 27 Figure 28 CAT...

Page 21: ... bus can connect up to 63 access control panels but preferably 32 is recommended maximum 3 To eliminate signal attenuation in communication cables and suppress inter ference if the bus is longer than 200 meters set the number 8 DIP switch to the ON position This is equivalent to a parallel connection of one 120 ohm resistance between the 485 and 485 lines SINgLE InBio Pro Panel MuLTI InBio Pro Pan...

Page 22: ...er 7 DIP switch to restore InBio Pro Panel to factory default settings The parameters which gets reset are device IP address communication password gateway and subnet mask 2 The switch is OFF by default When it is moved up and down for three times within 10 seconds and finally returned to OFF position the factory settings will be restored after the access control panel is restarted To reset factor...

Page 23: ... set down wards it indicates 0 off For example to set a device number 39 1 2 4 32 which corresponds to the binary code 111001 put number 1 2 3 and 6 to ON position as illustrated below For more details please check the table at the end of this document DIP Switch Setting Terminal Resistance Number 8 is for setting the RS485 termination resistance Putting the switch to ON position is equivalent to p...

Page 24: ...guIDE Installation Diagram Sensor CEILINg INDOOR OuTDOOR InBio Pro Access Control Bundle Electric Lock Exit Button Indoor Wiegand card reader Outdoor Wiegand card reader Figure 36 Ethernet Communication wire 220 110 V Input RS485 Network Communication wire ...

Page 25: ... c Click Sign in to enter the Web Server Note The ZKPanlWeb function supports only the large capacity version of inBio Pro To help users conveniently manage controllers the built in Web Server function is added to some models With this function a user can connect to the control ler through a PC and enter the IP address of the controller to access the web users can also use the Web Server function ...

Page 26: ...anels INSTALLATION guIDE 2 Language Settings Click change the language in which the server interface is displayed and click Confirm 3 Use Conditions of the Server Click and you can view the version of the current server as well as the browser and resolution recommended for the server ZKPanelWeb 1 Change of the Administrator s Password a Click The following page is displayed ...

Page 27: ...l Panels INSTALLATION guIDE 4 Online Help of the Server If you met some problems when using the server click to view or down load the user help document ZKPanelWeb 5 Exit Click and then click Confirm to return to the server login page ...

Page 28: ... which are used in the communications between device and PC operating steps a Click Setting TCP IP b Input the device s IP address Subnet Mask Default gateway IP address the default IP is 192 168 1 201 and you can modify according to the actual Subnet Mask the default subnet mask is 255 255 255 0 and you can modify according to the actual Default Gateway the default gateway is 0 0 0 0 and you can ...

Page 29: ...to the actual Communication Password Indicates that network communication is encrypted The default value is null and you can set its value If you configure the communication password here the same communication password must be configured on the server before the connection can be set up ZKPanelWeb 4 System 1 User Settings Click Edit to change the login password of an administrator or a user Domai...

Page 30: ... information remaining capacity and network information of the current device 3 System Settings Click Reboot The device will be restarted ZKPanelWeb 2 Time Settings you can manually configure the controller time or synchronize the controller time with the PC time and click Confirm to complete the setting ...

Page 31: ...party reader or a stand alone reader to a InBio Pro panel Connect the wiegand output to the WD0 and WD1 of the stand alone readers on the panel s reader port Note The board can only supply 12 V DC 300mA power so an external power supply may be required 5 What is the SD card slot used for SD card stores transactions from the panel and creates a back up in additional to internal memory 6 What kind o...

Page 32: ...OFF 10 OFF ON OFF ON OFF OFF 11 ON ON OFF ON OFF OFF 12 OFF OFF ON ON OFF OFF 13 ON OFF ON ON OFF OFF 14 OFF ON ON ON OFF OFF 15 ON ON ON ON OFF OFF 16 OFF OFF OFF OFF ON OFF 17 ON OFF OFF OFF ON OFF 18 OFF ON OFF OFF ON OFF 19 ON ON OFF OFF ON OFF 20 OFF OFF ON OFF ON OFF 21 ON OFF ON OFF ON OFF 22 OFF ON ON OFF ON OFF 23 ON ON ON OFF ON OFF 24 OFF OFF OFF ON ON OFF 25 ON OFF OFF ON ON OFF 26 OFF...

Page 33: ...OFF ON OFF ON 42 OFF ON OFF ON OFF ON 43 ON ON OFF ON OFF ON 44 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 46 OFF ON ON ON OFF ON 47 ON ON ON ON OFF ON 48 OFF OFF OFF OFF ON ON 49 ON OFF OFF OFF ON ON 50 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 52 OFF OFF ON OFF ON ON 53 ON OFF ON OFF ON ON 54 OFF ON ON OFF ON ON 55 ON ON ON OFF ON ON 56 OFF OFF OFF ON ON ON 57 ON OFF OFF ON ON ON 58 OFF ON OF...

Page 34: ... lock relay output Switching voltage V 12V Use regulated DC power adaptor only Switching Current A 2 Auxiliary relay output Switching voltage V 12V Use regulated DC power adaptor only Switching Current A 1 25 Switch Aux input VIH V VIL V Pull up resistance Ω 4 7k The input ports are pulled up with 4 7k resistors WIEGAND Input Voltage V 10 8 12 13 5 Current mA 500 ZK ElectRIC lock Voltage V DC 10 8...

Page 35: ...er of doors controlled Four Door four door one way and two door two way Number of readers supported 4 Types of readers supported 26 bits WIEGAND others upon request Number of Inputs 12 4 Exit Device 4 Door Status 4 AUX Number of Outputs 8 4 Form C relay for lock and 4 Form C relay for Aux output Weight 7 8lbs 3 55kg Enclosure Metal Cabinet Mounting Wall Mount Dimensions Bundle Only 15 7in x 3 56in...

Page 36: ...ames mentioned are used for identification purposes only and may be the trademarks of their respective owners All specifications are subject to change without notice All rights reserved ZK Building Wuhe Road gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394 www zkteco com ...

Reviews: