Safety Instructions  3 

1.2

 

Installation Cautions 

1)

 

The conduits of wires under relay must be matched with metaled conduits, other wires can use PVC conduits, 
to prevent failure caused by rodent damage. Although a control panel is designed with good antistatic, 
lightning-proof, and leakage-proof functions, ensure its chassis and the AC ground wire are connected 
properly and the AC ground wire is grounded physically. 

2)

 

It is recommended not to plug/unplug connection terminals frequently when the system is energized. Be sure 
to unplug the connection terminals before starting any relevant welding job. 

3)

 

Do not detach or replace any control panel chip without permission, because unprofessional operation may 
cause damage to the control panel. 

4)

 

It is recommended not to connect any other auxiliary devices without permission. All non-routine operations 
must be communicated to our engineers in advance. 

5)

 

A control panel should not share one power socket with any other large-current device. 

6)

 

It is preferable to install card readers and buttons at heights of 

1.4-1.5m

 above the ground, but the heights 

are subject to proper adjustment according to customers’ usual practice. 

7)

 

It is advised to install control panels at places easy of maintenance, like 

a weak electric well

8)

 

It is strongly recommended that the exposed part of any connection terminal should 

not be longer than 

4mm

, and specialized clamping tools may be used to avoid short-circuit or communication failure resulting 

from accidental contact with excessive exposed wires. 

9)

 

To save access control event records, export data periodically from control panels. 

10)

 

Get prepared countermeasures according to application scenarios for unexpected power failure, like 

selecting power supply with UPS

11)

 

If RS485 reader is connected externally and shares the power supply for the device (The control panel does 
not support fingerprint verification of RS485 reader), it is recommended that the connection between the EXT 
RS485 port and the reader be no longer than 100m. Otherwise, it is recommended that the reader use a 
separate power supply. 

12)

 

The connection between a PC and a control panel should be shorter than 1200m for RS485 communications. 
A length 

within 800m

 is recommended to make communications more stable. 

13)

 

To protect the access control system against the self-induced electromotive force generated by an electronic 
lock at the instant of switching off/on, it is necessary to 

connect a diode in parallel

 (please use the FR107 

delivered with the system) with the electronic lock to release the self-induced electromotive force during 
onsite connection for application of the access control system. 

14)

 

It is recommended that an electronic lock and a control panel should 

use respective power supplies

15)

 

It is recommended to use the power supply delivered with the system as the control panel power supply. 

16)

 

In a place with strong magnetic interference, galvanized steel pipes or shielded cables are recommended, and 
proper grounding is required. 

Summary of Contents for C5S120

Page 1: ...USER MANUAL C5S110 120 140 Version 1 1 Date Apr 2018 ...

Page 2: ...About This Manual This manual introduces C5S110 120 140 access control panel installation connection and user instructions ...

Page 3: ...cess Control Panel Wires 7 3 3 Control Panel System Installation 8 3 4 Control Panel Connection Terminals 9 3 5 Connection with Door Sensors Exit Switches and Auxiliary Input Devices 12 3 6 Connection with Readers 13 3 7 Relay Output Connection 15 3 8 Access Control Panel System Power Supply Structure 17 4 Equipment Communication 19 4 1 Access Control Networking Wires and Wiring 19 4 2 TCP IP Comm...

Page 4: ...tempt unauthorized repair of the equipment Disassembly or detachment is likely to cause shock or other risks All repair jobs should be done by qualified repair personnel 7 Damages in need of repair In any of the following cases first disconnect the power supply from the equipment and notify qualified repair personnel for repairs The power cord or connector is damaged There is entry of liquid or an...

Page 5: ... We will not be responsible for the damages or injuries caused thereby Before installation switch off the external circuit that supplies power to the system including locks Before connecting the equipment to power supply ensure the output voltage is within the specified range Never connect power before completion of installation ...

Page 6: ... tools may be used to avoid short circuit or communication failure resulting from accidental contact with excessive exposed wires 9 To save access control event records export data periodically from control panels 10 Get prepared countermeasures according to application scenarios for unexpected power failure like selecting power supply with UPS 11 If RS485 reader is connected externally and shares...

Page 7: ...ol panel Over current protection for the power supply to card readers Instant over voltage protection for all input output ports Instant over voltage protection for communication ports 2 2 Product Technical Parameters Working power supply Rated voltage 12V 20 DC rated current 3A rated current for C5S140 5A Working environment Temperature 10 C 50 C humidity 20 80 Electronic lock relay output The ma...

Page 8: ...oduction 5 3 WLAN indicator green flashing indicates the system is communicating in wireless WIFI mode 4 DOOR indicator green flashing indicates a door opening signal a door is opened Diagram of C5S140 indicators ...

Page 9: ...you need to install the control panel separately without the chassis you can use the guide rail to fix the control panel The following figures show how to fix the control panel using the guide rail The following shows the chassis appearance and internal structure Panel Box Appearance Panel Box Inside Get the Panel off the track Remove the set screws Control Panel Temper Switch Power Adapter Guide ...

Page 10: ...to the equipment The access control wires must be separated according to heavy and light current the control panel wires electronic lock wires and exit button wires must run through their respective casing pipes TCP IP network communication wire or PoE line for PoE only RS485 network communication wire Control Panel Door sensor Electronic lock Exit button Indoor reader Outdoor reader Outdoor Indoo...

Page 11: ...spite the preceding example of four door one way two way C5S140 also can be connected to two door two way C5S110 can be connected to one door one way two way at most and C5S120 can be connected to two door one way two way The access control management system consists of two parts management workstation PC and control panel ...

Page 12: ...h power wires A management workstation is actually a PC connected to the network By running the access control management software installed in the PC access control management personnel can remotely perform various management functions like adding deleting a user viewing event records opening closing doors and monitoring status of each door in real time 3 4 Control Panel Connection Terminals C5S1...

Page 13: ... DIP Switch PC RS485 Auxiliary Output Ethernet PoE Interface USB Slot Reset Disassembly Mains Battery Abnormality Alarm Power Input Auxiliary Input 1 Door State Indicator 2 Door EXT RS485 Wiegand Reader 1 Wiegand Reader 2 Antenna Connector Wiegand Reader 3 Wiegand Reader 4 ...

Page 14: ...us indicator 4 PC RS485 indicates the RS485 cable is connected to the PC through this port The EXT RS485 port can be connected externally to RS485 reader 5 All the terminals mentioned above are set through relevant access control software Please see the respective software manual for details Rotary DIP Switch PC RS485 Auxiliary Output Ethernet PoE Interface USB Slot Reset Disassembly Mains Battery...

Page 15: ...oor With a door sensor switch an access control panel can detect illegal opening of a door and will trigger an output of alarm Moreover if a door is not closed within a specified period of time after it is opened the door control panel will also prompt an alarm It is recommended to select two core wires with a gauge over 0 22 mm2 A door sensor may be omitted if it is unnecessary to monitor online ...

Page 16: ...control panel 3 Auxiliaryinput C5S series control panel provides one auxiliary input interface which are connected to infrared body detectors smoke detectors gas detectors window magnetic alarms wireless exit switches etc Auxiliary inputs are set through relevant access control software Please see the respective software manual for details Connections between C5S140 and Door Sensors Exit Switches ...

Page 17: ... RS485 interface can supply maximum 750 mA 12V current So the entire current consumption should be less than this max value when the readers share power with the panel In calculation please use max current of the reader and start current is usually more than twice of the normal work current please consider of this situation For example use the KR502M RS card reader the standby current is less than...

Page 18: ...sed as a control lock by default and the other used as an auxiliary output C5S120 has three relays two used as control locks by default and the other one used as auxiliary outputs C5S140 has five relays four used as control locks by default and the other one used as auxiliary outputs The relays for auxiliary outputs may be connected to monitors alarms door bells etc Auxiliary outputs are set throu...

Page 19: ...ess control system against the self induced electromotive force generated by an electronic lock at the instant of switching off on it is necessary to connect a diode in parallel please use the FR107 delivered with the system with the electronic lock to release the self induced electromotive force during onsite connection for application of the access control system The following uses the example o...

Page 20: ...Installation and Connection 17 3 8 Access Control Panel System Power Supply Structure Access Control Panel System Power Supply PoE System ...

Page 21: ...oE the TCP IP network interface of the access control panel can serve as a PoE interface and a PC communication interface The PoE switch must conform to IEEE802 3at standards To prevent power failure of a control panel from making the whole system unable to work normally the access control management system is usually required to have one UPS at least and access control locks are powered externall...

Page 22: ...ally or vertically They should be protected in casing pipes like plastic or iron water pipes to be selected according to the technical requirements of indoor distribution Metal hoses are applicable to ceiling wiring but must be secure and good looking Shielding measures and shielding connection If the electromagnetic interference in the wring environment is found strong in the survey before constr...

Page 23: ...mmunication wires should be connected by means of bus cascade connection instead of in a star form to achieve a better shielding effect by reducing signal reflection during communications 3 Considering stability of communication it is recommended the length of RS485 bus is less than 600m 4 Up to 16 device numbers can be set because the rotary DIP switch on the control panel has 16 bits Therefore a...

Page 24: ...access the ZKPanelWeb Note 1 Must configure IP address of the controller and Server PC in the same network segment 2 When the controller s IP address is unknown you can obtain the IP through searching device in the software 3 Click TCP IP Settings to modify the IP address and gateway address Extended Network Card Setting is set when the controller is connected to TCP IP reader For detailed setting...

Page 25: ...connection status shows connected as shown in Figure 2 and the device s WLAN indicator turns green figure 1 figure 2 Note The PC server must be on the same network segment as the router wireless network 6 Switch network connection in the software For ZKAccess3 5 software Select the added C5S control panel on the Device page and click More Set up WiFi as figure 3 set the WIFI parameters of the cont...

Page 26: ...ates device number 1 and so on Switch F indicates device number 15 You can rotate the 0 F bits of the rotary DIP switch to corresponding positions to set device numbers and then restart the control panel to make the setting take effect Address numbers cannot be repetitive 4 6 USB Upgrade The USB slot is primarily used for control panel upgrade the following describes how to use it 1 Create a Udisk...

Reviews: