background image

BG1000 Series Barrier Gate 

User Manual 

P a g e

 | 2 

 

Copyright©2020 ZKTECO CO., LTD. All rights reserved. 

ZKTeco does not assume responsibility for any errors or omissions in the information or 
documents which are referenced by or linked to this manual. The entire risk as to the results 
and performance obtained from using the information is assumed by the user. 

ZKTeco in no event shall be liable to the user or any third party for any incidental, 
consequential, indirect, special, or exemplary damages, including, without limitation, loss of 
business, loss of profits, business interruption, loss of business information or any pecuniary 
loss, arising out of, in connection with, or relating to the use of the information contained in 
or referenced by this manual, even if ZKTeco has been advised of the possibility of such 
damages.  

This manual and the information contained therein may include technical, other 
inaccuracies or typographical errors. ZKTeco periodically changes the information herein 
which will be incorporated into new additions/amendments to the manual. ZKTeco reserves 
the right to add, delete, amend or modify the information contained in the manual from 
time to time in the form of circulars, letters, notes, etc. for better operation and safety of the 
machine/unit/equipment. The said additions or amendments are meant for improvement 
/better operations of the machine/unit/equipment and such amendments shall not give any 
right to claim any compensation or damages under any circumstances. 

ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions 
due to any non-compliance of the instructions contained in this manual (ii) in case of 
operation of the machine/unit/equipment beyond the rate limits (iii) in case of operation of 
the machine and equipment in conditions different from the prescribed conditions of the 
manual. 

The product will be updated from time to time without prior notice. The latest operation 
procedures and relevant documents are available o

http://www.

zkteco

.com

 

If there is any issue related to the product, please contact us. 

ZKTeco Headquarters 

Address

 

ZKTeco Industrial Park, No. 32, Industrial Road,  

Tangxia Town, Dongguan, China. 

Phone 

 

+86 769 - 82109991 

Fax 

 

+86 755 - 89602394 

For business-related queries, please write to us a

[email protected]

. 

To know more about our global branches, visi

www.zkteco.com

 

 

Summary of Contents for BG1000 Series

Page 1: ...ead the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please visit our Company s website www zkteco com User Manual BG1000 Series Barrier Gate Date December 2020 Doc Version 1 0 English ...

Page 2: ...e content s of the manual seems unclear or incomplete please contact ZKTeco before starting the operation and maintenance of the said equipment It is an essential pre requisite for the satisfactory operation and maintenance that the operating and maintenance personnel are fully familiar with the design and that the said personnel have received thorough training in operating and maintaining the mac...

Page 3: ...he right to add delete amend or modify the information contained in the manual from time to time in the form of circulars letters notes etc for better operation and safety of the machine unit equipment The said additions or amendments are meant for improvement better operations of the machine unit equipment and such amendments shall not give any right to claim any compensation or damages under any...

Page 4: ...endent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhancement of the development and plenty of market applications the team has gradually constructed an identity authentication ecosystem and smart security ecosystem which a...

Page 5: ...table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This implies about the notice or pays attention to in the manual The general information which helps in performing the operations faster The information which is significant Care taken to avoid da...

Page 6: ...CTION WITH UHF CONTROLLER 15 7 2 CONNECTION WITH LOOP DETECTOR 15 7 3 CONNECTION WITH VR10 RADAR SENSOR 16 7 4 CONNECTION WITH INFRARED PHOTOCELL DETECTOR 17 7 5 8 FUNCTIONAL PARAMETER SETTINGS 19 MAINBOARD PARAMETER SETTINGS 19 8 1 8 1 1 OPERATING PROCEDURE 19 PARAMETER SETTINGS DESCRIPTION 20 8 2 REMOTE CONTROL PAIRING AND UNPAIRING 21 8 3 SET DELAY FOR AUTOMATIC CLOSING AFTER OPENING THE BOOM 2...

Page 7: ...BG1000 Series Barrier Gate User Manual P a g e 6 Copyright 2020 ZKTECO CO LTD All rights reserved 12 SAFETY PRECAUTIONS 33 13 TRANSPORTATION AND STORAGE 33 14 WARRANTY 33 ...

Page 8: ...nd Functionalities The operating speed is 1 5s and the speed can be adjusted according to different boom arm lengths Reversible left and right directions The transmission mechanism is simple compact and easy to install on site Interactive and stylish chassis LED design Equipped with digital control monitoring thus supports delay in automatic close automatic test rise fall output status display Sup...

Page 9: ...BG1000 Series Barrier Gate User Manual P a g e 8 Copyright 2020 ZKTECO CO LTD All rights reserved 3 Appearance and Dimensions ...

Page 10: ...oom Length 3m 4 5m 6m Spring Size Φ4 5mm Φ5 5mm Φ6 5mm Boom Type Telescopic straight boom Chassis Dimensions 350mm 300mm 1020mm Ingress Protection Level IP54 Chassis Weight 45kgs Motor Type 24V DC brushless motor Output Power 120W Rated Current 6A Power Supply 220V AC 50Hz 110V AC 60Hz Operating Temperature 35o C to 70o C Operating Humidity 90 MCBF 3 million times Remote Control Distance 30m ...

Page 11: ...he boom but it cannot be increased After the boom has been cut it is important to set the spring balance again to achieve a new balance The bottom of the spring contains two plastic nuts designed to adjust the new balance 3 When powered on do not change the wire connection inside 4 Connect the GND to the cabinet for ensured protection Cable Embedding 5 2 1 A φ25 protective sleeve and a cable are r...

Page 12: ...BG1000 Series Barrier Gate User Manual P a g e 11 Copyright 2020 ZKTECO CO LTD All rights reserved Dimensions ...

Page 13: ... is powered on to run the test process be sure to install the barrier boom of the corresponding length for the test If the barrier boom is not installed please adjust and remove the spring under the guidance of a professional 2 If the length of the barrier boom is cut and adjusted the tightness of the spring and the position of the hanging hole need to be adjusted accordingly to avoid the abnormal...

Page 14: ...nboard Wiring Instructions 1 Please disconnect the power supply before wiring 2 To switch the input voltage to 110V please note that you need to set the DIP switch as shown in the below image 3 Check carefully whether the terminals are tightened and whether the wiring is firm 4 The wiring diagram of the control panel is given below ...

Page 15: ...BG1000 Series Barrier Gate User Manual P a g e 14 Copyright 2020 ZKTECO CO LTD All rights reserved BG1000 Wiring Diagram of Mainboard Connection with LPR Camera 7 1 ...

Page 16: ...opyright 2020 ZKTECO CO LTD All rights reserved Connection with UHF Controller 7 2 Note The Reader1 and 2 of Inbio260 Controller corresponds to LOCK1 Reader3 and 4 corresponds to LOCK2 Connection with Loop Detector 7 3 Anti smash and Auto close function ...

Page 17: ... All rights reserved Coil Circumference Coil Number 3m Based on requirements ensure that the inductance is between 100μH and 200μH 3m to 6m 5 to 6 turns 6m to 10m 4 to 5 turns 10m to 25m 3 turns 25m 2 turns Connection with VR10 Radar Sensor 7 4 Anti smash and Auto close function ...

Page 18: ...BG1000 Series Barrier Gate User Manual P a g e 17 Copyright 2020 ZKTECO CO LTD All rights reserved Connection with Infrared Photocell Detector 7 5 Anti smash function ...

Page 19: ...BG1000 Series Barrier Gate User Manual P a g e 18 Copyright 2020 ZKTECO CO LTD All rights reserved Anti smash and Auto close function ...

Page 20: ...e opening and closing strokes Mainboard Parameter Settings 8 1 Key Description Menu Menu options Confirm and Enter Enter Confirm and Exit Open Decrease parameter value Close Increase parameter value 8 1 1 Operating Procedure Long press the Menu button to view the parameter options Press the key Close Open to select the required parameter Press Menu to open the selected parameter press to adjust th...

Page 21: ...ensitivity L 4 30 30 30 Motor Strength Adjustment Default L 5 70 70 70 Horizontal Boom Barrier Adjustment L 6 5 5 8 Test Mode Selection 0 Manual 1 Automatic default L 7 0 0 0 Turn on Memory function 0 No Memory 1 Memory 4 Peak mode default L 8 0 0 0 Vertical Boom Barrier Adjustment L 9 5 5 8 Deceleration stroke adjustment of the first stage of opening brake L L 45 65 40 Deceleration stroke adjustm...

Page 22: ...ic boom dropping delay after starting 0 Disabled 1 255 is the time corresponding to the delay in automatic boom dropping L20 0 0 0 Remote Control Pairing and Unpairing 8 3 1 Remote Control Pairing Long press Menu then press to select L F L15 Press Menu again to set the parameter value At this time the LED display value is 000 and then press any button on the remote control until you hear a beep so...

Page 23: ... Menu button then press to select the L20 parameter and then press the Menu to set the parameter value after selection At this time the display will be 000 i e in the disabled state Set the delay value as per the requirements Finally press Enter to exit the menu For example if it is set to 005 the machine will automatically close after 5 seconds after opening the barrier ...

Page 24: ...just them without the guidance of professionals to avoid mechanical damage 1 Adjust the horizontal position of the barrier boom The connecting boom crank will be an overlapping structure and the two rotation points of the connecting boom are coincident with the output shaft of the reducer at 3 points and a line This is the horizontal position of the barrier boom If you find that the barrier boom i...

Page 25: ...rank is in an unfolded shape and the two rotation points of the connecting boom and the output shaft of the reducer are in an unfolded 3 point line This is the vertical position of the barrier boom If it is found that the barrier boom is not in the vertical position and is inclined at this time then loosen the 2 screws of the rocker rocker arm turn the barrier boom to the vertical and tighten the ...

Page 26: ... as follows Step 1 With the barrier boom is in a vertical state turn off the power and then remove the spring as shown in the figure Step 2 Use a socket wrench to remove the linkage arm Unscrew the screws at both the ends loosen the linkage arm washer behind the screws must be safe as shown in the figure Step 3 Remove the spring connecting arm washer behind the screw must be safe as shown in the f...

Page 27: ...ght 2020 ZKTECO CO LTD All rights reserved Step 4 Loosen the 2 screws on the spindle connecting arm and take out the rocker arm as shown in the figure Step 5 Take out the spindle connecting arm and place it in another direction key L R as shown in the figure ...

Page 28: ...eserved Step 6 Remove the 4 screws on the mechanical limited block move the limit block to the right symmetrical position and then tighten the screws Step 7 Connect the linkage arm to the spindle connecting arm and install it gasket at the back of the screw must be safe as shown in the figure ...

Page 29: ...e User Manual P a g e 28 Copyright 2020 ZKTECO CO LTD All rights reserved Step 8 Connect and install the spring connecting arm with the spindle connecting arm gasket on the back of the screw must be safe as shown in the figure ...

Page 30: ...t then connect it to the spring connecting arm and install it as shown in the figure Step 10 After adjusting the vertical and parallel angles of the barrier boom finally tighten the two screws of the spindle connecting arm as shown in the figure Step 11 Finally set the L D parameter on the control panel to 2 note that L is 1 and R is 2 ...

Page 31: ...spring and the greater the tension The lower the spring screw blue box the looser the spring and the lesser the tension Notes 1 When the barrier boom is at 45 it is the best balance 2 The spring wire diameter is adapted to different boom lengths 3m boom with φ4 5mm 4 5m boom with φ5 5mm 6m boom with φ6 5mm If the boom is too short i e less than 2m do not install the spring ...

Page 32: ... 2020 ZKTECO CO LTD All rights reserved 10 Product Packing List Material Quantity Chassis Explosion Screw M12X140 4 Keys 2 Barrier Boom 1 Boom Pressure Plate 1 Chassis Pressure Plate 2 Wireless Remote 2 Barrier Boom hexagon bolt M10X70 2 Machine 1 User manual 1 ...

Page 33: ...3 Tighten the wiring Description The power indicator is on the landing boom indicator is normal and the motor is not running Cause 1 The motor wiring might be wrongly connected or the wiring is loose 2 The internal encoder of the motor may work abnormally 3 The motor stroke limit exceeds the position Solution 1 Check the wiring according to the wiring diagram and tighten the wiring if required 2 R...

Page 34: ...e power immediately If the product works abnormally please contact the dealer in time Please do not try to repair it by yourself If you handle it without authorization the company is not responsible for any damage 13 Transportation and Storage When loading and unloading the product handle it with care During transportation and storage place it in a dry and corrosive free environment The product sh...

Page 35: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2020 ZKTECO CO LTD All Rights Reserved ...

Reviews: