3. Connecting pattern 

EBC-A05

A+

V+

V-

A-

Battery

+

-

COMM

Power

 

3.1 Testing Ports 

The  tester  has  four  banana  jacks  which  connect  with  A+/V+/V-/A-.A+  and  A-  ports  are 
connected  with  the  positive  and  negative  poles  of  the  test  objects,  working  as  the  current 
channel  in  charging  and  discharging.  V+  and  V-  ports  are  connected  with  the  positive  and 
negative poles of the test objects, working as the voltage channel in voltage tests. This way of 
using  four  individual  cables  will  help  eliminate  the  effect  of  wires  on  the  test  result  and 
improve the test precision.     

3.2 PC Connection 

The tester can be connected with a computer through a designated USB-TTL cable.   

3.3 Input Power: 

The  tester  works  on  a  power  supply  of  above  DC  12V/3.5A  and  interface  specification  of 
5.5/2.1 (inside positive and outside negative). 

4. Display and setting 

4.1 Buttons 

ON   

——

 start and stop 

       SET 

——

 set up and switch 

       INC  

——

 page up and increase 

       DEC 

——

 page down and decrease 

4.2 Testing Interface 

  

 

   

Summary of Contents for EBC-A05

Page 1: ...http www zketech com EBC A05 User Manual Copyright C 2006 2015 ZKE Technology Multifunction Electronic Load EBC A05 User Manual ...

Page 2: ... battery or battery packs up to 10V at 0 1 3 00A Max charging current Power current 0 5A Standard Charging Support NiMH NiCd LiPo LiFe and Pb batteries CV Charging Support custom CC CV charging Fixed Output 5V 2A output support charging portable power banks and cell phones 5 Discharging 0 30 00V 0 1 5 00A max power 60W and automatic current limiting above CC Discharging Discharging a relatively un...

Page 3: ... negative poles of the test objects working as the voltage channel in voltage tests This way of using four individual cables will help eliminate the effect of wires on the test result and improve the test precision 3 2 PC Connection The tester can be connected with a computer through a designated USB TTL cable 3 3 Input Power The tester works on a power supply of above DC 12V 3 5A and interface sp...

Page 4: ...rging discharging charging test you can check test results of each step by a short press on INC or DEC buttons Press the ON button to start testing and one more press to stop You can open setting interface by press on the SET button for 2 seconds in the stop state This function is invalid when the tester being connected with the PC software 4 3 Setting Interface The cursor default is on mode setti...

Page 5: ...e second step of auto discharging setting The first parameter discharging current the second parameter cut off voltage the third parameter interval between step switches a 5 10 minute waiting time is suggested in a switch between charging and discharging to cool the battery 4 Custom charging First line mode and charging current setting Second line CV voltage cut off current testing stops when the ...

Page 6: ...arging 5 Precautions 1 Positive and negative connections should not be reversed 2 Always use the tester within the allowed range 3 The maximum charging current should be set below power current 0 5A 4 This manual is applicable to firmware 08 24 Please download the latest software for a upgrade if your version is released earlier than the date 5 PC software http zke2006 blog 163 com blog static 199...