S
martLPR
®
Access User Manual
Installation
Quercus Technologies
20
2.3. Ceiling installation
In case the unit must be installed on the ceiling, the minimum horizontal distance from the unit
to the license plate must be of 5 m and the angle between the unit and the floor must not exceed
30º.
The maximum height where the unit could be installed
(h), can be calculated as
follows:
h=L·tanβ
where for a minimum horizontal distance of 5 m, we get h= 2.9 m.
2.4. Electrical installation and cables needed
Each SmartLPR
®
Access recognition unit must have the following cables:
●
Power cable: 3x1.5mm2 or 3x2.5mm2 section cable (alternating current) or 2x1.5mm2
(direct current).
●
Shielded Network cable: UTP cable, category 5 (ethernet networking).
●
Signal cable: 7-pin shielded cable (if the 2 inputs, one output and Wiegand
communication are required) with a 0.5mm
2
cross-section.
For more information about the power consumption of each unit, please refer to the “Technical Data
Sheets” downloaded at http://downloads.quercus.biz/.
Distance (L
≥5m)
He
igh
t
(h)
Camera angle (β≤30º)
Summary of Contents for SmartLPR Access
Page 21: ...SmartLPR Access User Manual Installation Quercus Technologies 22 ...
Page 35: ...SmartLPR Access User Manual Configuration Quercus Technologies 36 Configuration ...
Page 42: ...SmartLPR Access User Manual Advanced Concepts Quercus Technologies 43 Advanced concepts ...
Page 48: ...SmartLPR Access User Manual Annexes Quercus Technologies 49 Annexes ...
Page 60: ...SmartLPR Access User Manual Annexes Quercus Technologies 61 R D Director ...
Page 62: ...SmartLPR Access User Manual Annexes Quercus Technologies 63 ...