(1) Post
the
mounting
template
on
the
wall
.
Drill
the
holes
according
to
the
marks
on
the template
(
holes
Version: V1.0
Date: October 2010
(2) Remove
the
screw
on
the bottom
(3) Take
away
the
back
plate.
(5) Fix
the
device
to
the
back
plate.
according
to
the
mounting paper
.
(4) Fix
the
back
plate on the wall
RS485
TCP/IP
Lock Sensor
①
③
Alarm
RS232
/
RS485 Converter
②
NC
LOCK
-
+
DC12V
+
NC
LOCK
+
-
NO
LOCK
-
-
FR 107
+
-
FR 107
+12V
+12V
+12V
+12V
GND
GND
GND
GND
NC
NC
NC
NC
NC
NO
NO
NO
NO
NO
GND
GND
GND
GND
GND
COM
COM
COM
COM
COM
AL-
AL-
AL-
AL-
AL-
AL+
AL+
AL+
AL+
AL+
SEN
SEN
SEN
SEN
SEN
BUT
BUT
BUT
BUT
BUT
BELL+
BELL+
BELL+
BELL+
BELL+
BELL-
BELL-
BELL-
BELL-
BELL-
NO
LOCK
-
+
DC12V
+
-
+
-
FR 107
-
+
DC12V
+
-
-
+
DC power
-
+
DC12V
-
+
DC power
+
-
FR 107
+
DC12V
-
+
GND
+12V
Exit Button
⑤
External
Reader
④
Door
Bell
Door Bell
%
%
BUTTON
EXIT
EXIT
BUTTON
⑦
⑥
-
+
Alarm
Alarm Power
Exit Button
Door Sensor
MultiBio 700
(only for your reference)
Mounting Paper
10
11
12
Wiring
Hole
In st ru ct io n fo r th e Mo un ti ng P ap er
Be fo re t he d ev ic e is f as te ne d, p le as e
st ic k th e pa pe r to t he p la ce w he re y ou
wa nt t o in st al l it , th en m ak e ho le s an d
la y ca bl es a cc or di ng t o th e mo un ti ng
pa pe r.
for
screw
and
wiring
).
of
device
.
Access
Control
System
Function
(1) If a registered user verified, the device will
export the signal
to unlock the door.
(3) If only the d
llegal
removed, the device will
evice being i
ly
(4)
is
External
card
r
eader
supported.
(5)
is
it is
External
exit
button
supported
,
convenient to open the
export alarm signal.
door inside.
(7) Supports
,
modes
with
RS485 TCP
/
IP
to connect
PC. One PC can
manage multiple devices.
(6) External door bell is supported.
①:
‘
‘I’: device output current, ‘
’: lock voltage,
’: lock current
U
LOCK
I
LOCK
(1)
T
he
system
supports
NO LOCK
and
NC LOCK. For example the NO LOCK (normally open at power on) is connected
with ’NO’ terminal, and the NC LOCK is connected with ‘NC’ terminal.
(equipped in the package) to prevent the self-inductance EMF affect the system,
do not reverse the polarities
.
3
.
Lock
Connection
!
Warning: No operating with power on
(1) Share
power with the lock:
A. U
LOCK
=12V,
I-I
LOCK
>1A
…… ①
B. The
lock is
near
to
the
device.
Device
share
power
with the lock
:
Device
does
not
share
power
with the lock
:
A.
=12V I-
≤
1A;
U
LOCK
I
LOCK
B
≠
12V;
. U
LOCK
C. The
lock is far apart from the
device.
Voltage output
≤
DC 12V for Alarm
4
.
Other
Parts Connection:
5
.
Power Connection:
Input DC 12V, 500mA (50mA standby)
Positive is connected with ‘+12V’, negative is connected
with ’GND’ (
do not reverse the polarities
).
(2) Does not share
power with the lock:
2. Structure and Function
(2) Door sensor will detect the on-off state. If the door is un-
expected opened or improperly closed, the alarm signal
(digital value) will be triggered.
MultiBio 700 Installation Guide
1. Equipment Installation
(2) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode