StudSensor

 EDGE

Stud Finder 

StudSensor

 EDGE

Stud Finder 

The Zircon StudSensor

 EDGE stud finder finds 

the edges of wood and metal studs up to 19 mm 

deep in walls. It features a sleek, high-impact 

case, with a patent-pending pinch grip design, 

and a new SpotLite

®

 Pointer.

The Zircon StudSensor

 EDGE stud finder finds 

the edges of wood and metal studs up to 19 mm 

deep in walls. It features a sleek, high-impact 

case, with a patent-pending pinch grip design, 

and a new SpotLite

®

 Pointer.

1. INSTALLING THE BATTERY

Do not attempt to unscrew 

the back of the tool.

Push in the battery door tab 

at the bottom of the tool and 

open the door. Insert a new 9-Volt 

battery, matching the positive (+) 

and negative (-) terminals to the 

icons printed on the back. Snap the battery 

into place and replace the door.

2. IMPORTANT OPERATING TIPS— 

  PLEASE READ CAREFULLY

• 

Tool Position:

 For proper use, always place 

scanner flat against the surface before 

turning on power.

• 

Power:

 Press and hold in the Power button  

continuously while in use.

• 

Operation:

 Move the unit slowly, while 

keeping it flat against the wall. Do not rock, 

tilt, or lift it.

3. TURNING ON/CALIBRATING THE  

  TOOL AND FINDING A STUD

• Place unit flat on wall. Press and hold the 

Power button. During calibration, SpotLite

®

 

arrow and red EDGE light will flash, unit 

will beep, and green READY light will stay 

illuminated. Do not move the unit until 

calibration is complete. 

• If you calibrate over a stud, the unit will 

beep repeatedly. Move the unit a few inches 

right or left, release the Power button, and 

start over.

1. INSTALLING THE BATTERY

Do not attempt to unscrew 

the back of the tool.

Push in the battery door tab 

at the bottom of the tool and 

open the door. Insert a new 9-Volt 

battery, matching the positive (+) 

and negative (-) terminals to the 

icons printed on the back. Snap the battery 

into place and replace the door.

2. IMPORTANT OPERATING TIPS— 

  PLEASE READ CAREFULLY

• 

Tool Position:

 For proper use, always place 

scanner flat against the surface before 

turning on power.

• 

Power:

 Press and hold in the Power button  

continuously while in use.

• 

Operation:

 Move the unit slowly, while 

keeping it flat against the wall. Do not rock, 

tilt, or lift it.

3. TURNING ON/CALIBRATING THE  

  TOOL AND FINDING A STUD

• Place unit flat on wall. Press and hold the 

Power button. During calibration, SpotLite

®

 

arrow and red EDGE light will flash, unit 

will beep, and green READY light will stay 

illuminated. Do not move the unit until 

calibration is complete. 

• If you calibrate over a stud, the unit will 

beep repeatedly. Move the unit a few inches 

right or left, release the Power button, and 

start over.

Probable Causes

Probable Causes

Solutions

Solutions

Situation

Situation

• Move several inches to the left or right and start again.

• Move several inches to the left or right and start again.

• Turn scanner off, move over a few inches, press Power 

button, and start again.

• On rough surfaces, place thin cardboard on wall, 

scanning through it to help slide scanner more smoothly.

• Turn scanner off, move over a few inches, press Power 

button, and start again.

• On rough surfaces, place thin cardboard on wall, 

scanning through it to help slide scanner more smoothly.

• Check for other studs equally spaced to either side 

 

(12, 16, or 24 in. [305, 406, or 610 mm] apart) or the 

same stud at several places directly above or below  

the first scan area.

• Use CAUTION when nailing, sawing, or drilling into 

walls, floors, and ceilings where these items may exist.

• Check for other studs equally spaced to either side 

 

(12, 16, or 24 in. [305, 406, or 610 mm] apart) or the 

same stud at several places directly above or below  

the first scan area.

• Use CAUTION when nailing, sawing, or drilling into 

walls, floors, and ceilings where these items may exist.

No indications.

No indications.

Unit beeps repeatedly.

Unit beeps repeatedly.

Detects other objects 

besides studs.
Finds more targets 

than there should be.

Detects other objects 

besides studs.
Finds more targets 

than there should be.

• No studs in that area.

• No studs in that area.

• Tool was calibrated 

over a stud or on 

dense part of wall.

• Tool tilted or lifted 

during scan.

• Tool was calibrated 

over a stud or on 

dense part of wall.

• Tool tilted or lifted 

during scan.

• Electrical wiring 

and metal/plastic 

pipes may be near 

or touching back 

surface of wall.

• Electrical wiring 

and metal/plastic 

pipes may be near 

or touching back 

surface of wall.

SpotLite

®

 Pointer

SpotLite

®

 Pointer

Stud Edge Groove

Stud Edge Groove

Red EDGE Light

Red EDGE Light

Green READY Light

Green READY Light

Battery Door Tab

Battery Door Tab

Power Button

Power Button

Visit www.zirconinternational.com 
for the most current instructions.

Visit www.zirconinternational.com 
for the most current instructions.

StudSensor, SpotLite, and Zircon are trademarks or registered 

trademarks of Zircon Corporation.

StudSensor, SpotLite, and Zircon are trademarks or registered 

trademarks of Zircon Corporation.

4. OPERATING CAUTIONS

Depending on the proximity of electrical wiring 

or pipes to the wall surface, the StudSensor

 

EDGE may detect them in the same manner 

as studs. Caution should always be used when 

nailing, sawing, or drilling into walls, floors, 

and ceilings that may contain these items.
To avoid surprises, remember that studs or 

joists are normally spaced 16 in. (406 mm)  

or  24 in. (610 mm) apart and are 1

1

2

 in.  

(35 mm) to in width. Anything closer together 

or a different width may not be a stud, joist, 

or firebreak. 

Always turn off the power when working 

near electrical wires.

5. SCANNING DIFFERENT SURFACES

Freshly painted walls: 

May take one week or 

longer to dry after application. 

Wallpaper:

 The StudSensor

 EDGE functions  

normally on walls covered with wallpaper or 

fabric, unless the materials are metallic foil, 

contain metallic fibers, or are still wet after 

application.

Lath & plaster:

 Due to irregularities in plaster 

thickness, this tool is not recommended for use 

on lath & plaster.
The StudSensor

 EDGE cannot scan for 

wood studs and joists through ceramic tile or 

carpeting and pad.

Note: Sensing depth and accuracy can vary 

due to moisture, content of materials, wall 

texture, and paint.

4. OPERATING CAUTIONS

Depending on the proximity of electrical wiring 

or pipes to the wall surface, the StudSensor

 

EDGE may detect them in the same manner 

as studs. Caution should always be used when 

nailing, sawing, or drilling into walls, floors, 

and ceilings that may contain these items.
To avoid surprises, remember that studs or 

joists are normally spaced 16 in. (406 mm)  

or  24 in. (610 mm) apart and are 1

1

2

 in.  

(35 mm) to in width. Anything closer together 

or a different width may not be a stud, joist, 

or firebreak. 

Always turn off the power when working 

near electrical wires.

5. SCANNING DIFFERENT SURFACES

Freshly painted walls: 

May take one week or 

longer to dry after application. 

Wallpaper:

 The StudSensor

 EDGE functions  

normally on walls covered with wallpaper or 

fabric, unless the materials are metallic foil, 

contain metallic fibers, or are still wet after 

application.

Lath & plaster:

 Due to irregularities in plaster 

thickness, this tool is not recommended for use 

on lath & plaster.
The StudSensor

 EDGE cannot scan for 

wood studs and joists through ceramic tile or 

carpeting and pad.

Note: Sensing depth and accuracy can vary 

due to moisture, content of materials, wall 

texture, and paint.

LIMITED 1 YEAR WARRANTY

Zircon Corporation, (“Zircon”) warrants this product to be 

free from defects in materials and workmanship for one year 

from the date of purchase. Any in-warranty defective product 

returned to Zircon*, freight prepaid with proof of purchase 

date and $5.00 to cover postage and handling, will be repaired 

or replaced at Zircon’s option. This warranty is limited to 

the electronic circuitry and original case of the product and 

specifically excludes damage caused by abuse, unreasonable 

use or neglect. This warranty is in lieu of all other warranties, 

express or implied, and no other representations or claims 

of any nature shall bind or obligate Zircon. Any implied 

warranties applicable to this product are limited to the one year 

period following its purchase. IN NO EVENT WILL ZIRCON BE 

LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES RESULTING FROM POSSESSION, USE OR 

MALFUNCTION OF THIS PRODUCT.

In accordance with government regulations, you are advised 

that: (i) some states do not allow limitations on how long an 

implied warranty lasts and/or the exclusion or limitation of 

LIMITED 1 YEAR WARRANTY

Zircon Corporation, (“Zircon”) warrants this product to be 

free from defects in materials and workmanship for one year 

from the date of purchase. Any in-warranty defective product 

returned to Zircon*, freight prepaid with proof of purchase 

date and $5.00 to cover postage and handling, will be repaired 

or replaced at Zircon’s option. This warranty is limited to 

the electronic circuitry and original case of the product and 

specifically excludes damage caused by abuse, unreasonable 

use or neglect. This warranty is in lieu of all other warranties, 

express or implied, and no other representations or claims 

of any nature shall bind or obligate Zircon. Any implied 

warranties applicable to this product are limited to the one year 

period following its purchase. IN NO EVENT WILL ZIRCON BE 

LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES RESULTING FROM POSSESSION, USE OR 

MALFUNCTION OF THIS PRODUCT.

In accordance with government regulations, you are advised 

that: (i) some states do not allow limitations on how long an 

implied warranty lasts and/or the exclusion or limitation of 

incidental or consequential damages, so the above limitations 

and/or exclusions may not apply to you, and further. (ii) this 

warranty gives you specific legal rights and you may also have 

other rights which vary from state to state. 
Return product freight prepaid with proof of purchase date 

(dated sales receipt) and $5.00 to cover postage and handling, to:

Zircon Corporation

 

*Attn: Returns Department 

1580 Dell Avenue

Campbell, CA  95008-6992 USA
Be sure to include your name and return address. Out of 

warranty service and repair, where proof of purchase is not 

provided, shall be returned with repairs charged C.O.D. Allow 4 

to 6 weeks for delivery. 

Customer Service: 1-800-245-9265 or 1-408-963-4550

 

Monday–Friday, 8:00 a.m. to 5:00 p.m. PST 

E-mail: [email protected]

©2011 Zircon Corporation • P/N 64842 Rev B 07/11

incidental or consequential damages, so the above limitations 

and/or exclusions may not apply to you, and further. (ii) this 

warranty gives you specific legal rights and you may also have 

other rights which vary from state to state. 
Return product freight prepaid with proof of purchase date 

(dated sales receipt) and $5.00 to cover postage and handling, to:

Zircon Corporation

 

*Attn: Returns Department 

1580 Dell Avenue

Campbell, CA  95008-6992 USA
Be sure to include your name and return address. Out of 

warranty service and repair, where proof of purchase is not 

provided, shall be returned with repairs charged C.O.D. Allow 4 

to 6 weeks for delivery. 

Customer Service: 1-800-245-9265 or 1-408-963-4550

 

Monday–Friday, 8:00 a.m. to 5:00 p.m. PST 

E-mail: [email protected]

©2011 Zircon Corporation • P/N 64842 Rev B 07/11

6. HELPFUL HINTS (See also number 2, IMPORTANT OPERATING TIPS)

6. HELPFUL HINTS (See also number 2, IMPORTANT OPERATING TIPS)

• After calibration is 

complete, continue 

to hold the Power 

button and slowly 

slide the unit 

across the surface.

• When the top red 

EDGE light is lit, 

the beep sounds, 

and the SpotLite

®

 

Pointer arrow 

shines, you have 

located the edge  

of the stud. 

Mark this spot.

• Continue scanning 

beyond the marked 

spot until the red 

EDGE light turns 

off. Slide unit in 

reverse direction  

to locate other 

edge of stud.  

Mark this second 

spot. The middle 

of the stud is 

centered between 

the two marks.

• After calibration is 

complete, continue 

to hold the Power 

button and slowly 

slide the unit 

across the surface.

• When the top red 

EDGE light is lit, 

the beep sounds, 

and the SpotLite

®

 

Pointer arrow 

shines, you have 

located the edge  

of the stud. 

Mark this spot.

• Continue scanning 

beyond the marked 

spot until the red 

EDGE light turns 

off. Slide unit in 

reverse direction  

to locate other 

edge of stud.  

Mark this second 

spot. The middle 

of the stud is 

centered between 

the two marks.

FCC Part 15 Class B Registration Warning

This device complies with Part 15 of FCC Rules. Operations subject to the following two conditions: (1) this device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Part 15 Class B Registration Warning

This device complies with Part 15 of FCC Rules. Operations subject to the following two conditions: (1) this device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Summary of Contents for StudSensor EDGE

Page 1: ... 19 mm deep in walls It features a sleek high impact case with a patent pending pinch grip design and a new SpotLite Pointer SpotLite Pointer Stud Edge Groove Red EDGE Light Green READY Light Battery Door Tab Power Button StudSensor SpotLite and Zircon are trademarks or registered trademarks of Zircon Corporation ...

Page 2: ...urface before turning on power Power Press and hold in the Power button continuously while in use Operation Move the unit slowly while keeping it flat against the wall Do not rock tilt or lift it 3 TURNING ON CALIBRATING THE TOOL AND FINDING A STUD Place unit flat on wall Press and hold the Power button During calibration SpotLite arrow and red EDGE light will flash unit will beep and green READY ...

Page 3: ...ight is lit the beep sounds and the SpotLite Pointer arrow shines you have located the edge of the stud Mark this spot Continue scanning beyond the marked spot until the red EDGE light turns off Slide unit in reverse direction to locate other edge of stud Mark this second spot The middle of the stud is centered between the two marks ...

Page 4: ...d joist or firebreak Always turn off the power when working near electrical wires 5 SCANNING DIFFERENT SURFACES Freshly painted walls May take one week or longer to dry after application Wallpaper The StudSensor EDGE functions normally on walls covered with wallpaper or fabric unless the materials are metallic foil contain metallic fibers or are still wet after application Lath plaster Due to irre...

Page 5: ...xpress or implied and no other representations or claims of any nature shall bind or obligate Zircon Any implied warranties applicable to this product are limited to the one year period following its purchase IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION USE OR MALFUNCTION OF THIS PRODUCT In accordance with government regulations yo...