background image

6

USER 

MANUAL

LASER SAFETY

The ZippyYum Scancase contains a laser 
compliant with FDA 21 CFR 1040.10, 
subchapter J. Refer to the technical 
specifications for additional details. Every 
device is tested for compliance with Class 
II laser power limitation.

       WARNING! 

The laser is activated whenever 
taking an infrared temperature. 

 

 

Avoid directly exposing eyes to 
Scancase’s laser as this may result 
in eye damage.

Never point the laser at another 
person. When using model 

ZYGS003-M or ZYGS004-M to take 

a person’s forehead temperature 
the app will automatically disable 
the laser.

Always keep Scancase out of 
the reach of children and avoid 
indirect eye exposure via reflective 
surfaces such as glass and mirrors.

If Scancase is damaged, always 
perform an accuracy check prior 
to using Scancase for critical 
temperatures.

Summary of Contents for SCANCASE

Page 1: ...SCANCASE USER MANUAL Models ZYGS004 ZYGS004 M Updated June 23 2021 Android Works with...

Page 2: ...stallation Removal 9 Installing the App 12 Pairing 13 LED Indicator 15 Surface Internal Temp 17 Troubleshooting 18 Scanning Barcodes 21 Accuracy Check 23 Cleaning 25 Reset Procedure 27 Distance to Spo...

Page 3: ...mocouple connector probes An internal battery charged with a standard USB C connector powers the case and also boosts your phone s battery Scancase models ZYGS003 and ZYGS003 M are compatible with iOS...

Page 4: ...for support resources including a knowledge base IN APP RESOURCES You can also access the knowledge base in the Help Support area from the main menu of any ZippyYum app CONTACT US To reach our support...

Page 5: ...5 USER MANUAL FEATURES LED indicator Reset button Barcode scanner Laser indicator Infrared sensor K type thermocouple probe jack USB C charging port Rotating arm...

Page 6: ...rared temperature Avoid directly exposing eyes to Scancase s laser as this may result in eye damage Never point the laser at another person When using model ZYGS003 M or ZYGS004 M to take a person s f...

Page 7: ...le with the iPhone SE iPhone 8 and iPhone 7 iPhone SE iPhone 8 iPhone 7 Scancase models ZYGS004 and ZYGS004 M are compatible with the UMIDIGI A3X Android phone only UMIDIGI A3X See page 41 for iPhone...

Page 8: ...8 01 SETUP...

Page 9: ...ipped with or without a phone pre installed You can install or remove a compatible phone by following these steps Use the included screwdriver to unscrew the 2 screws located on the lower rear panel o...

Page 10: ...10 USER MANUAL Next slide the bottom part of Scancase down gently to separate it from the top section of the case INSTALLATION REMOVAL Slide down...

Page 11: ...AL If removing a phone gently unplug the connector then slide the phone out of Scancase If installing an phone slide it into Scancase and gently plug Scancase s connector into your phone INSTALLATION...

Page 12: ...with the GoVentory or GoTemp app on an iOS or Android device before being used To install the app s tap below or visit www zippyyum com apps Once the GoVentory or GoTemp app is installed log into the...

Page 13: ...13 USER MANUAL PAIRING MAC address PRO TIP Your scancase s unique identifier also known as its MAC address is printed on the back of the device as shown below You may need it during pairing...

Page 14: ...ncases will show as SCANCASE_ with being the last two digits of its MAC address The LED indicator will blink once a scancase is selected The ZippyYum Scancase will pair automatically or prompt you for...

Page 15: ...tatus to its iOS device INDICATOR OFF Power off sleep mode or dead battery RED LED Battery critically low should be charged ORANGE LED Battery charging continue charging GREEN LED Battery charged read...

Page 16: ...16 02 TAKING TEMPS...

Page 17: ...on a grill use Scancase s built in probe to take an internal probe temperature Cold Holding Example Use your free gloved hand to mix or move the top layer of veggies in a food pan to get the internal...

Page 18: ...te infrared temperatures If multiple items are temping out of range verify your equipment is turned on and set to the proper temperature If taking infrared temperatures verify proper steps are being t...

Page 19: ...sing infrared Avoid measuring reflective surfaces like aluminum wrapping unless a matte surface is on top like a label When a sudden change of temperature occurs like walking into a freezer Scancase m...

Page 20: ...20 03 SCANNING BARCODES...

Page 21: ...e for proper scanning Scancase cannot be submerged during scanning For best results keep Scancase between 2 to 5 5 cm to 12 cm away from the barcode while scanning Scancase can scan when slightly angl...

Page 22: ...22 04 SERVICE CLEANING...

Page 23: ...it for 2 minutes then stir thoroughly Hold Scancase about 6 to 8 directly above the ice and take an infrared temperature Make sure Scancase is pointed straight down and not angled otherwise you may be...

Page 24: ...IR accuracy COMPLETE ACCURACY CHECK For a more detailed accuracy check procedure for both hot and cold temperatures please visit the ZippyYum knowledge base You can access the knowledge base in the H...

Page 25: ...lways be kept free of dirt dust moisture smoke and debris WARNING Do not submerge Scancase or wash in a dishwasher To clean the barcode scanner or body of Scancase moisten a cloth with a water based m...

Page 26: ...rate infrared temperatures To clean the infrared lens lightly moisten a cotton swab with water and insert and swirl it in the lens opening to clean any debris Repeat with a clean cotton swab until it...

Page 27: ...AL To reset Scancase use a thin pin like a paperclip to press the reset button located on the top area on the front of Scancase Scancase will blink orange 5 times to confirm the reset RESET PROCEDURE...

Page 28: ...the product determines the dimensions of this area The further away from the product the larger the area being measured The laser helps indicate where Scancase is measuring Hold Scancase about 6 away...

Page 29: ...29 05 TECHNICAL SPECS...

Page 30: ...ptical Power 14 F to 113 F 10 C to 45 C 50 F to 104 F 10 C to 40 C 10 to 90 RH 1 000mA MODELS ZYGS003 ZYGS003 M RH 1 500mA MODELS ZYGS004 ZYGS004 M 5V 0 dBM 2 000 mAH MODELS ZYGS003 ZYGS003 M 4 000 mA...

Page 31: ...tected Temperature Unit IR Measurement Range Probe Measurement Range Repeatability Response Time Probe Resolution Probe Accuracy at Room Temp 77 F or 25 C IR Resolution Electromagnetic Interference El...

Page 32: ...F or 140 F 0 95 preset but adjustable 1 to 12 2 5 cm to 30cm 12 1 Image 1 60th second Diagonal 54 Level 45 Vertical 36 2D 7 5 mil 1D 5mil Max 100 000 lux 360 IR Accuracy at Room Temp 77 F or 25 C IR...

Page 33: ...to 140 mm 50 to 250 mm Incline Angle Pitch Angle Depth of Field Code 128 10 Mil 18 bytes Paper Code Depth of Field Code 128 18 bytes Phone Code Depth of Field QR 10 mil 160 bytes Paper Code Depth of...

Page 34: ...is for the Scancase case only Please refer to the owner s manual for your compatible iOS device for its waterproof rating Complete protection is not guaranteed under all conditions Read this guide fo...

Page 35: ...35 06 WARRANTY LEGAL...

Page 36: ...y obligation is to correct such defects by repair or replacement at its option if within the warranty period and the product is returned prepaid by the customer There are no other or implied warrantie...

Page 37: ...le installation delivery or use of Scancase shall never exceed the purchase price of the product The remedies provided herein are the exclusive remedies under this warranty whether based on contract t...

Page 38: ...IC 1502A ZYGS003 iOS 1502A ZYGS004 Android EUROPEAN UNION DIRECTIVES 1999 5 EC Radio Telecommunications Terminal Equipment R TTE Directive 2014 35 EU Low Voltage LVD Directive 2014 30 EU Electromagnet...

Page 39: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Page 40: ...l est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage...

Page 41: ...579C E3500A A2298 BCG E3500A 579C E3500A iPhone 8 FCC ID IC ID A1863 BCG E3159A 579C E3159A A1905 BCG E3172A 579C E3172A A1906 BCG E3171A 579C E3171A A1907 BCG E3159A 579C E3159A iPhone 7 FCC ID IC ID...

Reviews: