CARE AND MAINTENANCE
Z.I.P.P.E.R Maschinen Austria
www.Zipper-maschinen.at
Seite 35
HOLZSPALTER / LOG SPLITTER ZI-HS8PT / ZI-HS10T / ZI-HS12T
15
CARE AND MAINTENANCE
A T T E N T I O N
Cleaning and maintenance with a connected machine!
Property damage and personal injury due to unintentional switching on the machine!
Therefore:
Before maintenance work disconnect the machine from the power supply!
The machine is low maintenance and contains little parts that must undergo a maintenance
operator.
Faults or defects that may affect the safety of the machine, must be rectified immediately.
Repair work may only be carried out by qualified personnel!
15.1
Maintenance and Servicing
Controls for the maintenance of the machine
Loose or lost screws
Daily before starting
Damage to any part
Daily before starting
Function of the control system part
Daily before starting
Pay attention to oil spills under the
machine!
Daily before starting
Check the Hydraulic Oil / refill if
necessary
Daily before starting
Clean the piston housing
Daily before starting
Change the hydraulic oil
After initial start-up after 25 working hours /
Every 50 hours, however, / at least once a
year!
15.2
Change the hydraulic oil
The hydraulic system is a closed system consisting of the oil tank, oil pump and control valves.
Low oil level can lead to damage to the pump. The oil level should never be lower than 1-2cm
below the surface of the oil tank. Oil change frequency see table.
Make sure that no foreign particles from getting into the oil tank!
Dispose of the used oil after an oil change PROPERLY!
After changing the oil, let the log splitter for a few minutes at idle and proceed in accordance with
section 13.2.4.
The following oils are suitable for the splitter:
ZI-HS8PT / ZI-HS10T / ZI-HS12T
DEA HD B46
ESSO NUTO H46
SHELL TELLUS 10-46
EROLUB HLP46