CLASS: 0X85 COMMAND_CLASS_ASSOCIATION
The Association Command Class is used to associate the Mini
Keypad RFiD/Z-Wave to other devices. When a tag or code is read,
the Mini Keypad RFiD/Z-Wave will send a notifi cation to the Z-Wave
devices in its association group. It will also report the state of the
tamper alarm to the devices in this association group.
Number of groupings:
1
Maximum supported nodes per group:
5
CLASS: 0X84 COMMAND_CLASS_WAKE_UP
The Wake Up Command Class is used at battery-operated devices.
This class allows the Mini Keypad RFiD/Z-Wave to wake up
occasionally to notify others devices, that the Mini Keypad RFiD/Z-
Wave is ready to receive commands. After receiving the commands
the Mini Keypad RFiD/Z-Wave will go into sleep mode again. The wake
up interval can be set using the WAKE_UP_INTERVAL_SET command.
The default value is 0x1C20 = 7200 sec = 2 hour
The default node is 0xFF = 255 (broadcast)
It is possible to send a
wake up notifi cation
on user interaction.
Besides sending a Wake Up Notifi cation automatically every 2 hours
(or any other time that is confi gured using the Wake Up Interval Set
command), the Mini Keypad RFiD/Z-Wave also sends a Wake Up
Notifi cation when:
The tamper alarm state changes (Mini Keypad RFiD/Z-Wave is
mounted or removed from the wall)
A tag read
A code is entered using the keypad
When the wake up time is set to 0 a
wake up notifi cation
is never send
periodically, only on user interaction.
CLASS: 0X70 COMMAND_CLASS_
CONFIGURATION_V1
CONFIGURE PARAMETERS:
1 |
Set to default
DESCRIPTION:
Set all confi guration values to default values (factory settings).
Read more in chapter Confi guration Reset.
SIZE:
1 byte*
PARAM1:
if 0xFF then set to default
PARAM2,3,4:
not used
2 |
Feedback time
DESCRIPTION:
To confi gure the time the beep is automatically turned off in seconds.
DEFAULT:
0x0F
PARAM1:
0x00 means disabled, 0xFF is endless.
PARAM2,3,4:
not used
SIZE:
1 byte*
3 |
Feedback timeout
DESCRIPTION:
To confi gure the timeout to wait for a
WAKEUP_NO_MORE_INFORMATION before the error beep is
automatically sound.
The error beeps are fi xed 8 beeps shortly after each other.
DEFAULT:
0x00
PARAM1:
0x00 means disabled
PARAM2,3,4:
not used
SIZE:
1 byte*
4 |
Feedback beeps per second
DESCRIPTION:
To confi gure the number of beeps per second.
Every beep is fi xed about 10ms.
DEFAULT:
0x02
PARAM1:
nr of beeps per second
PARAM2,3,4:
not used
SIZE:
1 byte*
5 |
The mode
DESCRIPTION:
To confi gure the operating mode.
DEFAULT:
0x01
SIZE:
1 byte*
PARAM1:
MODE 1:
Normal operating mode.
MODE 3:
Z-Wave chip is always on to request e.g. version or
manufacturer id. If any mode other then 3, that value will be reported
after a get but will be handled in SW as mode 1.
PARAM2,3:
not used.
* if a size is other then given size the frame is ignored totally so
confi guration values are not changed
CLASS: 0X71 COMMAND_CLASS_ALARM_V2
In the Mini Keypad RFiD/Z-Wave, this Command Class has two
purposes:
1 |
Identify the state of the tamper alarm. The device will send an
unsolicited report to the devices in its association group if tempering
is detected. The state of the tamper alarm can also be requested
by any other device.
2 |
Report tags or codes that are entered. The Mini Keypad RFiD/Z-
Wave will send an unsolicited report to the devices in its association
group with the UID that belongs to the code or tag and whether the
alarm system should be armed (Away) or disarmed (Home).
Every other alarm type that is requested will be ignored by
application.
CONFIGURATION RESET
The Mini Keypad RFiD/Z-Wave supports a confi guration reset function.
CONFIGURATION RESET MEANS
All confi guration values are defaulted.
Wake up interval is defaulted.
This function can be activated by sending a confi guration set frame:
CONFIGURATION_SET
PARAMETER:
0x01
SIZE:
0x01 (can’t be different from 1)
VALUE:
0xFF (can be any value except for 0x55)
When the value of confi guration value is requested 2 possible values
can be returned CONFIGURATION_REPORT
PARAMETER:
0x01
VALUE 0X55:
Confi guration settings of the device are altered.
The device will report this even if the confi guration parameters are
changed back to the default value.
VALUE 0XAA:
Confi guration of the device is untouched.
Note that this value will not change to 0x55 upon modifying the wake
up interval and that re-setting the value to 0xAA will always reset the
wake up interval.
ALWAYS AWAKE MODE
The always awake mode is used to request different values from the
device e.g. version and manufacturer specifi c.
NOTE:
in always awake mode the batteries will be drain very fast,
we do not recommend to use this mode for a longer period. Always
awake mode should only be used in order to confi gure the device.
NOTE:
it is not possible to use the buttons of the Mini Keypad RFiD/Z-
Wave while it is operating in always awake mode.
The always awake mode can be activated by:
CONFIGURATION_SET
PARAMETER:
0x05
SIZE:
0x01 (can’t be different from 1)
VALUE:
0x03 (mode 3)
The LED of the device will toggle on and off every second to notify you
that it is functioning in always awake mode.
The always awake mode can be deactivated by:
CONFIGURATION_SET
PARAMETER:
0x05
SIZE:
0x01 (can’t be different from 1)
VALUE:
Any value except 3
A second option to deactivate mode 3 is:
1 |
Remove batteries.
2 |
Wait ca 10 seconds
3 |
Replace batteries
SOUND NOTIFICATION
The Mini Keypad RFiD/Z-Wave is capable of playing a notifi cation
sound. This feature is typically used to notify a user that an alarm
system is being activated. Since the Mini Keypad RFiD/Z-Wave is a
non-listening device, the feature can not be controlled at all times.
It requires the Mini Keypad RFiD/Z-Wave to wake up and send a Wake
Up Notifi cation. After sending a notifi cation that a tag/code is read
(either an unknown or already confi gured code), the Mini Keypad
RFiD/Z-Wave will send a Wake Up Notifi cation. The notifi cation sound
can be turned on/off upon receiving any Wake Up Notifi cation.
See the section about the Wake Up Command Class for information
on when a Wake Up Notifi cation is send.
NOTIFICATION SOUND AND ACKNOWLEDGEMENT
The Mini Keypad RFiD/Z-Wave supports 3 types of notifi cation sound
confi gurations:
1 |
Notifi cation sound disabled (confi guration parameter 2 set to zero)
2 |
Notifi cation sound enabled (default, confi guration parameter 2 set
to auto-stop time).
3 |
Notifi cation sound and acknowledgement enabled (confi guration
parameter 3 set to acknowledgement timeout). In the fi rst mode, any
Basic or Switch Binary commands that are received are ignored.
The second mode, the default, can be used to inform a user that the
alarm system is armed or disarmed. To use this, you can send a Basic
or Switch Binary set on (0xFF) after receiving an Alarm Report and
the Wake Up Notifi cation following it.
The last mode can be used in situations where, for example, users
can only disarm the alarm system at certain times. In this case, the
user can be notifi ed whether or not its code or tag is accepted.
By confi guring confi guration parameter 3, you can set an
acknowledge timeout. Whenever a Lock/Unlock Alarm Report
containing an UID is send by the Mini Keypad RFiD/Z-Wave, the
acknowledgement timeout timer is started.
AFTER THIS THERE ARE TWO POSSIBILITIES:
1 |
The Mini Keypad RFiD/Z-Wave does not receive anything (or receives
a Wake Up No More Information upon its Wake Up Notifi cation). It
starts the error sound to notify the user of the unaccepted code.
2 |
The Mini Keypad RFiD/Z-Wave receives either a Basic (or Switch
Binary) on (to start the normal notifi cation sound) or off (to silently
acknowledge the code). The acknowledgement timer is stopped.
Note that it is actually possible to disable notifi cation sound, but
enable acknowledgement. In this case a silent acknowledgement can
be both a Basic/Switch Binary on (0xFF) or off (0x00).
TYPICAL OPERATION DIAGRAMS
The following diagrams show the user action that is required and
the messages which are being sent from/to the Mini Keypad RFiD/Z-
Wave for several basic operations, including optional functionality as
the sound notifi cation and UID acknowledgement.
CONFIGURE A NEW TAG
(for confi guring new codes, you can skip directly to the WAKE_UP_
NOTIFICATION).
RFID
Controller
Press HOME or
AWAY button
Hold tag in front of
the RFID
RFID does not
recognize tag
USER_CODE_
REPORT
(User ID 0, UID
Status 0, tag code
Controller searches
for empty UID
WAKE_UP_
NOTIFICATION
(possibly
interviewing RFID
for unused UID)
USER_CODE_SET
(new User ID, UID
Status 1, tag code
WAKE_UP_
NO_MORE_
NOTIFICATION
RFID
Controller
Press AWAY button
Hold tag in front of
the RFID or enter
user code and
press ENTER
Controller enables
the alarm system
WAKE_UP_
NOTIFICATION
ALARM_
REPORT_v2
(ZW Alarm Event
0x05, User ID)
SWITCH_
BINARY_SET
(value 0xFF)
WAKE_UP_
NO_MORE_
NOTIFICATION
RFID recognizes
tag/code
OPTIONAL: START NOTIFICATION
RFID
starts notifi cation
sound
MINI KEYPAD
RFiD/Z-WAVE