1. Remove the sensor cover

2. Make sure the sensor is powered

4. Press the button for 10 seconds, LED will blink once 

5. Release the button

WAKEUP MOTION DETECTOR

You can press the button once to wake up the device and send wakeup notification to 

controller. LED will blink once.

ASSOCIATIONS (Association Command Class Version 2)

This sensor supports 4 association groups; each group suppoerts max 4 associated 

nodes. This has the effect that when the sensor is triggered, all devices associated 

with the sensor will receive the relevant reports.

GROUP 1

 is lifeline service that is assigned to sensor status - Open/Close. It enables 

the sensor to send reports and readings to Z-Wave controller or Z-Wave Gateway 

whenever the sensor is triggered. This group supports:

NOTIFICATION_REPORT_V4

SENSOR_BINARY_REPORT_V2

SENSOR_MULTILEVEL_REPORT_V7

BATTERY_REPORT_DEVICE_RESET_LOCALLY_NOTIFICATION

GROUP 2

 allows sending control commands to associated devices such as relay 

module, lighting, etc. This association group is configured through the advanced 

parameters no. 2, 3, 5 and 8. This griup supports: BASIC_SET

GROUP 3

 allows sending notifications to associated devices int his group. This group 

supports: NOTIFICATION_REPORT_V4

GROUP 4

 allows sending sending Sensor Binary Report to associated devices in this 

group. This group supports: SENSOR_BINARY_REPORT_V2

Parameter number: 1

Parameter size: 1 byte

Available settings: 8 ~ 255

Default setting: 12

ADVANCED CONFIGURATION 

The follwing information is for someone that has some experience in setting up a 

Z-Wave system or someone that has computer software running a Z-Wave 

controller or Gateway. 

1. SENSITIVITY LEVEL SETTING

This parameter defines the sensitivity of PIR sensor. It’s recommended to test the 

sensor with moevements from a farthest end of the coverage area at the first time 

of use. If movements cannot be detected sensitively, simply adjust the sensitivity 

level with this parameter. This parameter can be configured with the value of 8 

through 255, where 8 means high sensitivity and 255 means low sensitivity.

Function: Sensivity Level Setting

Parameter size: 1 byte

Parameter number: 1

Available settings: 8 ~ 255

Default settings: 12

2. ON / OFF DURATION

This parameter determines how long the associated devices should have ON status. 

For instace, if this parameter is set to 30 (sec), the PIR sensor will send a BASIC_SET 

command to associated device with valu BASIC_SET level if PIR sensor is triggered 

and associated device will be turned on 30 seconds begore it’s turned off. This 

parameter value must be large as Parameter #. If user set this parameter to default 

by Configure CC, the parameter # will be set to default value.

Function: ON / OFF duration setting

Parameter size: 2 byte

Parameter number: 2

Available settings: 5~600 (seconds)

Default setting: 30

3. BASIC SET LEVEL

BASIC_SET command will be sent when PIR sensor is triggered. The receiver will 

take it into consideration; for instance, if a lamp module is receiving the BASIC_SET 

command of which value is decisive as to how bright of dim level of lamp module 

shall be.

Function: Basic Set Level

Parameter size: 1 byte

Parameter number: 2

Available settings: 0,1 ~ 99 or 255 0 - OFF, Alarm cancelling or turning device off

 

       1 ~ 99 or 255 - ON (Binary Switch Device)

 

       Dim level (Multilevel Switch Device)

Default setting: 255

4. PIR DETECTION FUNCTION ENABLED / DISABLED

This parameter can enable or disable the PIR sensor detecting function.

Function: Enabled / Disabled PIR function

Parameter size: 1 byte

Parameter number: 4

Available settings: 0 (disable) or 255 (enable)

Default setting: 255

5. AMBIENT ILLUMINATION LUX LEVEL

This parameter can set Lux value which determines when the light sensor is 

activated. If the ambient illumination level falls bellow this value and a person moves 

across or within the detection area, PIR sensor will send Z-Wave ON command (i.e. 

BASIC_set (value = parameter 3) to an associated device and activate it.

Function: Lux Level Set

Parameter size: 2 byte

Parameter number: 5

Available settings: 0~1000 (Lux)

Default setting: 100 (Lux)

6. RE-TRIGGER INTERVAL SETTING

This parameter can be used to adjust the interval of being re-triggered after the PIR 

sensor has been triggered. This parameter value must be less than Paramater #2. 

If user sets this parameter to default by Configure CC, the parameter #2 will be set 

to default value.

Function: Re-trigger interval setting

Parameter size: 1 byte

LED STATUS

1. When sensor is triggered, LED flashes red once.

2. When battery is installed, LED will flash red 5 times

3. Quickly, triple click on the code button to add the PIR sensor to the Z-Wave 

     network or delete PIR sensor

4. Press the code button for 10 seconds, the PIR sensor will be restored to factory 

    default settings

5. In normal conditions, the LED light is off

6. Press the button once to wakeup the device and send wakeup notification to 

     controller, LED flashes red once 

ADDING TO Z-WAVE NETWORK

1. Remove the sensor cover

2. Make sure the sensor is powered

3. Set Z-Wave controller or Z-Wave Gateway into inclusion mode

4. Press the button 3 times within 1.5 seconds and the device will enter inclusion 

    mode. LED will flash on and off 5 times.

REMOVING FROM Z-WAVE NETWORK

1. Remove the sensor cover

2. Make sure the sensor is powered

3. Set Z-Wave controller or Z-Wave Gateway into exclusion mode

4. Press the button 3 times within 1.5 seconds and the device will enter exclusion mode.

RESTORE TO DEFAULT SETTINGS

Reset procedure will delete all information on the Z-Wave network and Z-Wave 

Function: Lux Level Report

Parameter size: 2 byte

Parameter number: 9

Available settings: 0~1000 (Lux)

Default setting: 1

NOTIFICATION COMMAND CLASS

Once the sensor detects a movement, it will send NOTIFICATION_REPORT and 

SENSOR_BINARY_REPORT  to the nodes of lifeline to inform there is an intrusion 

event. When the movement is stopped, NOTIFICATION_REPORT and SENSOR_BI-

NARY_REPORT will be sent again to the nodes in lifeline.For compliant Z-Wave 300 

seires, there is also the Binary Sensor Command Class.

Notification Report Command:

Event prsent:

Command class: COMMAND_CLASS_NOTIFICAITON

Command: NOTIFICTION_REPORT

Notification type: NOTIFICATION_TYPE_HOME_SECURITY

Event: NOTIFICATION_EVENT_HOME_SECURITY_MOTION_DETECTION_

            UNKNOWN_LOCATION

Event clear:

Command class: COMMAND_CLASS_NOTIFICAITON

Command: NOTIFICTION_REPORT

Notification type: NOTIFICATION_TYPE_HOME_SECURITY

Event: NOTIFICATION_EVENT_HOME_SECURITY_NO_EVENT

Binary Sensor Report Command:

Event present:

Command class: COMMAND_CLASS_SENSOR_BINARY

Command: SENSOR_BINARY_REPORT

Sensor type: SENSOR_MOTION

Value: 0xFF

Event clear:

Command class: COMMAND_CLASS_SENSOR_BINARY

Command: SENSOR_BINARY_REPORT

Sensor type: SENSOR_MOTION

Value: 0x00

MULTILEVEL SENSOR

PIR Motion Sensor supports ambient luminance meassurement, the scale is LUX. 

And the default Multilevel sensor is luminance too. The settings of luminance 

sensor measurement are listed under “Advanced Configuration”

WAKEUP COMMAND CLASS

Majority of time sensor is in sleep status in order to conserve battery life.

The minimum wakeup interval is 300s.

The maximum wakeup interval is 16,777,200s (about 194 days)

Allowable interval among each wakeup interval is 60seconds, such as 360, 420, 480...

NOTE: The deault value is 12 hours. The value is longer, the battery life is greater.

BATTERY CHECK COMMAND:

The users can also enquire the battery status of the motion sensor by sending 

BATTERY_GET command. Once the sensor receives the command, it will return 

BATTERY_REPORT command. The motion sensor will send BATTERY_LEVEL = 

0xFF command to the Z-Wave controller to inform that the motion sensor is in dead 

battery status, otherwise BATTERY_LEEL value range is 0% to 100%.

COMMAND CLASSES

This sensor supports following Command Classes:

COMMAND_CLASS_ZWAVEPLUS_INFO (V2)

COMMAND_CLASS_VERSION (V2)

COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)

COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)

COMMAND_CLASS_POWERLEVEL (V1)

LIMITED PRODUCT WARRANTY

GENERAL TERMS

Nothing in this Limited Product Warranty affects your statutory rights as a 

consumer.

The Limited Product Warranty set forth below is given by Tri plus grupa d.o.o. 

(Europe) (herein referred to as “ZIPATO”). This Limited Product Warranty is only 

effective upon presentation of the proof of purchase. Upon further request by 

ZIPATO, this warranty card has to be presented, too.

EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY, ZIPATO MAKES 

NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE. ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN 

THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY 

LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD. TO THE 

EXTENT ALLOWED BY LOCAL LAW, THE REMEDIES IN THIS WARRANTY 

STATEMENT ARE CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES AGAINST 

ZIPATO. THEY DO NOT, HOWEVER, AFFECT OR RESTRICT THE RIGHTS YOU HAVE 

AGAINST THE BUSINESS YOU BOUGHT A ZIPATO PRODUCT FROM.  IN NO EVENT 

WILL ZIPATO BE LIABLE FOR LOSS OF DATA OR FOR INDIRECT, SPECIAL, 

INCIDENTAL, CONSEQUENTIAL (INCLUDING LOST PROFIT OR DATA), OR OTHER 

DAMAGE, WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. HOWEVER, 

NOTHING IN THIS AGREEMENT LIMITS ZIPATO’S LIABILITY TO YOU (I) IN THE 

EVENT OF DEATH OR PERSONAL INJURY TO THE EXTENT RESULTING FROM 

ZIPATO’S NEGLIGENCE, OR (II) TO THE EXTENT RESULTING FROM ANY 

FRAUDULENT MISREPRESENTATION ON THE PART OF ZIPATO, OR (III) TO THE 

EXTENT ARISING UNDER PART 1 OF THE CONSUMER PROTECTION ACT 1987 OF 

THE UNITED KINGDOM. SOME STATES OR COUNTRIES DO NOT ALLOW: (1) A 

DISCLAIMER OF IMPLIED WARRANTIES; (2) A LIMITATION ON HOW LONG AN 

IMPLIED WARRANTY LASTS OR THE EXCLUSION; OR (3) LIMITATION OF 

INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS. IN 

SUCH STATES OR COUNTRIES, SOME EXCLUSIONS OR LIMITATIONS OF THIS 

LIMITED WARRANTY MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES 

YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY 

VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY. YOU ARE ADVISED 

TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINA-

TION OF YOUR RIGHTS.

This Limited Product Warranty applies to ZIPATO branded hardware products 

(collectively referred to as “ZIPATO Hardware Products”) sold by ZIPATO (Europe), 

its European subsidiaries, affiliates, authorized resellers, or country distributors 

(collectively referred to as “ZIPATO Resellers”) with this Limited Product Warranty.

The term “ZIPATO Hardware Product” is limited to the hardware components and 

all its internal components including firmware. 

Parameter number: 6

Available settings: 1~8 (s)

Default setting: 8

7. LIGHT SENSOR POLLING INTERVAL

This parameter can set the light sensor to measure ambient illumination level 

interval time. NOTE: This value must be less than Wakeup Interval Time!

Function: Light Sensor Polling Interval

Parameter size: 2 byte

Parameter number: 7

Available settings: 60~3600 (seconds)

Default setting: 180 (s)

8. LUX LEVEL FUNCTION ENABLE

If this parameter is set to “1” and when Lux level is less than the value defined by 

parameter #5, PIR sensor will send a BASIC_SET command frame (i.e. BASIC_SET 

(value = parameter 3) to an associated device and activate it. If Lux level is greater than the 

value defined by parameter #5, PIR sensor will not send BASIC_SET command frame.

Function: Lux Level Enable

Parameter size: 1 byte

Parameter number: 8

Available sttings: 0, 1

Default setting: 0

9. AMBIENT ILLUMINATION LUX LEVEL REPORT

This parameter defines by how much Lux level must change in Lux to be reported to 

the main controller.

environment and protect human health. At Zipato, we understand and are 

committed to reducing any impact our operations and products may have on the 

environment. To minimize this impact Zipato designs and builds its products to be 

as environmentally friendly as possible, by using recyclable, low toxic materials in 

both products and packaging.

COPYRIGHT 

© 2017 Tri plus grupa d.o.o. All Rights Reserved.

No part of this manual may be reproduced or transmitted in any form without the 

expressed, written permission of Tri plus grupa d.o.o.

is in conformity with the standard(s) reckognized as giving presumption of 

compliance with the essential requirements in the specified European Directive.

The following harmonized standards were applied:

EN 300 220-1 V2.4.1:2012

EN 300 220-2 V2.4.1:2012

EN 301 489-1 V1.9.2 (2011-09)

EN 301 489-3 V1.6.1 (2013-08)

EN 62479:2010

EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013

Changes or modifications not expressly approved by Tri plus grupa d.o.o. for 

compliance could void the user’s authority to operate the equipment. 

DISPOSING AND RECYCLING YOUR PRODUCT 

When it reaches end of life, dispose of the product according to your local 

enviromental laws, guidelines and regulations.

This symbol on the product or packaging means that according

to local laws and regulations needs to be disposed of separately from household 

waste. Once this product has reached the end of its life, please take it to a 

collection point (recycle facilites) designated by your local authorities, some will 

accept your product for free or simply drop it off at your Zipato re-seller store. By 

recycling the product and its packaging in this manner you help to conserve the 

The term “ZIPATO Hardware Product” DOES NOT include any software applications 

or programs.

GEOGRAPHICAL SCOPE OF THE LIMITED PRODUCT WARRANTY

This Limited Product Warranty is applicable to Hardware Products sold by Zipato 

Resellers in all countries listed at the beginning of this document under the heading 

“Countries in which this ZIPATO Limited Product Warranty applies”. The Limited 

Product Warranty will be honored in any country where ZIPATO or its authorized 

service providers offer warranty service subject to the terms and conditions set 

forth in this Limited Product Warranty. However, warranty service availability and 

response times may vary from country to country and may also be subject to 

registration requirements.

LIMITATION OF PRODUCT WARRANTY

ZIPATO warrants that the products described below under normal use are free from 

material defects in materials and workmanship during the Limited Product 

Warranty Period set forth below (“Limited Product Warranty Period”), if the product 

is used and serviced in accordance with the user manual and other documentation 

provided to the purchaser at the time of purchase (or as amended from time to 

time).

ZIPATO does not warrant that the products will operate uninterrupted or error-free 

or that all deficiencies, errors, defects or non-conformities will be corrected.

This warranty shall not apply to problems resulting from: (a) unauthorized 

alterations or attachments; (b) negligence, abuse or misuse, including failure to 

operate the product in accordance with specifications or interface requirements; (c) 

improper handling; (d) failure of goods or services not obtained from ZIPATO or not 

subject to a then-effective ZIPATO warranty or maintenance agreement; (e) 

improper use or storage; or (f) fire, water, acts of God or other catastrophic events. 

This warranty shall also not apply to any particular product if any ZIPATO serial 

number has been removed or defaced in any way.

ZIPATO IS NOT RESPONSIBLE FOR DAMAGE THAT OCCURS AS A RESULT OF YOUR 

FAILURE TO FOLLOWTHE INSTRUCTIONS FOR THE ZIPATO HARDWARE 

PRODUCT.

LIMITED PRODUCT WARRANTY PERIOD

The Limited Product Warranty Period starts on the date of purchase from ZIPATO. 

Your dated sales or delivery receipt, showing the date of purchase of the product, is 

your proof of the purchase date. You may be required to provide proof of purchase 

as a condition of receiving warranty service. You are entitled to warranty service 

according to the terms and conditions of this document if a repair to your ZIPATO 

branded hardware is required within the Limited Product Warranty Period.

[Other than in respect of products for domestic use (in particular those listed in the 

first and last boxes in the table below), this Limited Product Warranty extends only 

to the original end user purchaser of this ZIPATO Hardware Product and is not 

transferable to anyone who obtains ownership of the ZIPATO Hardware Product 

from the original end-user purchaser.

PRODUCT WARRANTY PERIOD

Product type: Water sensor

Product warranty period: One (1) year

IMPORTANT

The content of “Product Type” listed above is subject to change; please refer to the 

www.zipato.com for latest update.

PERFORMANCE OF THE LIMITED PRODUCT WARRANTY

If a product defect occurs, ZIPATO’s sole obligation shall be to repair or replace any 

defective Zipato Hardware Product free of charge provided it is returned to an 

Authorized ZIPATO Service Centre during the Limited Warranty Period. Such repair or 

replacement will be rendered by ZIPATO at an Authorized ZIPATO Service Centre. All 

component parts or hardware products that are replaced under this Limited Product 

Warranty become the property of ZIPATO. The replacement part or product takes on the 

remaining Limited Warranty Period of the replaced part or product. The replacement 

product need not be new or of an identical make, model or part; ZIPATO may in its 

discretion replace the defective product (or any part thereof) with any reconditioned 

equivalent (or superior) product in all material respects to the defective product.

WARRANTOR

Tri plus grupa d.o.o.

Banjavciceva 11

10 000 Zagreb

CROATIA

TEL +385 (0)1 4004 404 

Fax +385 (0)1 4004 405

DECLARATION OF CONFORMITY

The manufacturer Tri plus grupa d.o.o declares under our sole responsibility that 

the product:

Marketing model:  PIR Motion Sensor

Regulatory model: ne-nas-pd01z

Trade/Brand name:  Zipato

6.