Warranty – Varipoint II

Your Varipoint II is precision built from the finest

materials and should give many years of trouble free

service. Zip Heaters (UK) Ltd warrants that should the

cylinder fail within five (5) calendar years or any

component fail within two (2) of installation, that part

will be repaired or replaced by Zip Heaters (UK) Ltd free

of charge, except as set out below, provided that the

failure is not due to accident, misuse, abuse, condition

of the water, frost or failure to follow installation

instructions or service requirements. The only charges

payable by the customer are the cost or removal,

re-installation and cartage, should any component

need to be returned for repair. This warranty does not

cover damage resulting from non-operation or

consequential damage to any goods, furnishings or

property. Zip Heaters (UK) Ltd’s liability will be limited to

replacement or repair at the option of Zip Heaters (UK)

Ltd. This warranty does not replace any statutory

warranty in relation to the Varipoint II.

Summary of Contents for VP103

Page 1: ...Instructions June 2004 3 Specification 4 Special notices 5 Dimensions 6 Installation Requirements 7 8 Positioning 9 Plumbing 9 Electrical 10 Commissioning 10 11 Operation Precautions 11 12 Maintenanc...

Page 2: ...ation High density CFC free polyurethane foam Safety features Expansion relief valve supplied Manually resettable over temperature safety cutout Facility for optional T P valve Water heater protected...

Page 3: ...s constructed from impact resistant plastic and heat losses are minimised by the CFC free polyurethane foam insulation The inner vessel is heavy gauge copper and pressure tested to 16 Bar An alloy she...

Page 4: ...Weight kg Under Basin litres A B C Empty Full VP103 Over 10 452 300 285 6 5 16 5 VP103UB Under 10 452 300 285 6 5 16 5 VP153 Over 15 452 300 285 7 5 22 5 VP153UB Under 15 452 300 285 7 5 22 5 6 Zip V...

Page 5: ...s under 4 bars fit accessory pack AQ2 Expansion vessel and check valve Where static water pressures are likely to exceed 4 bars fit accessory packs AQ2 and AQ3 Pressure reducing valve and line straine...

Page 6: ...is greater than 4 bar and expanded water cannot be accommodated in the pipework Using pack AQ2 and AQ3 expansion vessel check valve and pressure reducing valve 8 Zip Varipoint II Installation Mainten...

Page 7: ...Zip Heaters on 0870 608 8888 5 Position the Zip Varipoint to allow for future maintenance 6 Do not install in a location where the unit or connecting pipe can freeze Plumbing 1 Check the incoming wat...

Page 8: ...ver by sliding forwards d Pass the new cable through the entry point of the cover e Remake the connections f Ensure the cable is securely clamped g Refasten the cover Do not switch on the electrical s...

Page 9: ...inst frost damage but this protection does not extend to connecting pipework or fittings Economy setting Standard setting Setting for very hot water when large amounts of warm water mixed hot and cold...

Page 10: ...should be visually inspected regularly This is particularly important if the heater is located in a cupboard roof space or any other concealed location If there is any sign of leaks or seepage the hea...

Page 11: ...Possible causes Water not heating 1 Electricity supply fault 2 Over temperature cut out tripped 3 Faulty thermostat 4 Faulty element Discharge from 1 Thermostat fault any relief valve 2 Excessive main...

Page 12: ...asin Item Part No Description 1 VP0301 Element 2 2kW 2 VP0303 Thermostat 3 VP0304 Resettable Cut Out 4 VP0317 Element Gasket 5 VP0322 Wall Fixing Bracket Zip Varipoint II Underbasin Item Part No Descr...

Page 13: ...is not due to accident misuse abuse condition of the water frost or failure to follow installation instructions or service requirements The only charges payable by the customer are the cost or removal...