5. Direct connection

Note: Fasten the screw nuts with caution, to avoid damage to the valves or the piping 

system. 

For direct connection, the two ½ inch screw-in nipples and the ½ inch seals must be 

screwed into the ½ inch union nuts of the hot-water and cold-water connectors . The 

two ½ inch caps of the side outlets of the hot-water and cold-water connectors must 

be removed and screwed onto the open end of the screw-in nipples . Put the water 

flow reducer “

D

” into the hot water connection piece . The hot-water and cold-water 

connectors must then be screwed into the ⅜ inch union nut of the appliance inlet and 

outlet pipe, together with the ⅜ inch seals . 
For direct connection, it may be advisable to mount the appliance at a distance as illus-

trated alongside, using the spacer sleeves supplied . The two fixing holes near the lower 

pipe connections are also to be professionally fixed with 6 mm dowels and screws . 
The flared end of the pipes must be screwed into the ½ inch side outlets of the hot-

water and cold-water connectors with ½ inch union nuts and ½ inch seals . The holes 

required for the pipes must then be opened of the housing with the aid of a blunt 

implement .

In case of direct connection please note: Put the strainer into the cold water connec-

tion!

D

Summary of Contents for InLine DEX Next

Page 1: ...umber DEXNext DEX12Next Electronicallycontrolledinstantaneouswaterheaters 1 Installation instructions user manual 9120 34378 v1 00 Sept 2020 ZIP DEX Next DEX12 Next Technical support Tel 0345 6 005 00...

Page 2: ...12 Installation instruction 1 Overview 13 2 Technical specifications 14 3 Dimensions 14 4 Installation 15 Installation site 15 Mounting accessories 15 Installing the wall bracket 16 Installing connect...

Page 3: ...fittings and taps may be very hot when the appliance has been in use for some time The values stated on the rating plate must be observed In case of malfunction disconnect the mains power supply immed...

Page 4: ...pressure of 0 2 to 0 4MPa 2 4bar The appli ance must not be subjected to pressure exceeding 1 0MPa 10bar The appliance must only be used when correctly installed and in perfect working order The appli...

Page 5: ...nd where collected data can be read out The inlet temperature can be up to 70 C so that operation in connection with reheat ing e g in solar systems is possible It is possible to use the instantaneous...

Page 6: ...ations Preset applications can be selected here Simply tap on the right sensor key to open the selection Tap on the sensor key under an application symbol to activate it The temperatures are set at th...

Page 7: ...iance and dis played in graph format Water consumption Power consumption Total consumption costs Select or to scroll through the different periods The consumptions are dis played in diagrams over a pe...

Page 8: ...own electricity supplier Water price currency m Specify the water price of your own water supplier Load Shedding no function for DEX12 Next If further three phase appliances are connected a load shed...

Page 9: ...erature you need on the appliance and open the hot water tap Once you feel that the water is too hot do not add any cold water and instead enter a lower temperature on the appliance If you were to add...

Page 10: ...hows error symbol The appliance has detected an error Switch fuses off and on If sym bol wrench is still indicated contact customer service Flow rate of hot water too weak Outlet fitting dirty or calc...

Page 11: ...onsumption g Additional load profile the appropriate energy efficiency and the annual power consumption if applicable h Temperature setting for the temperature controller i Sound power level internal...

Page 12: ...ider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting...

Page 13: ...re cut out SDB Connecting terminal DEX Next 3 PE DEX12 Next 1 N PE Frame Cold water connection Fine filter Water splash protection sleeve DEX Next hood Non return valve Flow sensor Thermal sensor Ther...

Page 14: ...at t 38K 4 5 3 3 5 9 2 4 3 9 2 2 6 8 10 7 2 7 9 12 3 2 9 0 2 13 8 2 10 2 2 Rated volume 0 4l Rated pressure 1 0MPa 10bar Connecting type pressure resistant pressureless Heating system Bare wire heati...

Page 15: ...the wiring could be installed surface mounted Extension kit UDX Art no 34110 RDX RDX3 is necessary The instant water heater can be installed by means of this extension kit if the water connections ar...

Page 16: ...oles in the template fit over the double nipples Mark the drill holes according to the template and drill them using a 6mm drill Insert the included dowels 3 Pull down the faceplate and unscrew the ma...

Page 17: ...y slight cor rections are possible by carefully bending the threaded rod of the wall bracket However it must be possible to screw on the water connection pipes of the appli ance without applying force...

Page 18: ...ater flow reducer D into the hot water connection piece The hot water and cold water connectors must then be screwed into the inch union nut of the appliance inlet and outlet pipe together with the in...

Page 19: ...s to check the correct operation of the load shedding relay at low appliance output 35 degree celsius setpoint and low water flow rate Mode 2 must be selected if the load shedding relay flickers Only...

Page 20: ...itched off prior to electrical connection 1 Open the prepared breaking point S in the upper part of the appliance by pressing with a blunt implement e g srewdriver For surface mounted connection cable...

Page 21: ...rating at installation site depends on the local situa tion It is imperative to observe all data shown in the table Technical specifications in particular the required cable size and fuse protection...

Page 22: ...to 55 C if it is connected to a show er The temperature limit must be set to a value less or equal 55 C in the setting menu in consultation with the customer and the lock level must be activated When...

Page 23: ...filiated warm water tap valve several times until air no longer emerges from the pipe 9 Fit the hood of the appliance Then switch on the power again e g via activating the fuses The cold water connect...

Page 24: ...8 v1 00 Sept 2020 ZIP DEX Next DEX12 Next Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk ZipWaterUK TrafalgarHouse Rash sGreen Dereham Norfolk NR191JG 034560...

Reviews: