1. Position the Font template (provided) on the bench area. Ensure the
position you select is within the length of the supply tube and USB cable
fixed to the Tap Head Assembly. These cannot be extended.
2. Check again for correct positioning.The supply hoses must have constant
fall back to the tank assembly. Cut the holes as shown on the template.
3. Once holes are cut, locate the Font base in position, from the underside,
lightly tighten the securing rod with the nut and washer provided.
4. Apply a light smear of silicon sealant to the underside of the black base
ring, this will provide a water tight seal against the Font base when
clamped.
*
Ensure the plastic spacer is corectly located under the Font.
5. Now take the Tap Head Assembly. Feed the hoses and USB cable through
the Font base, then through the plastic spacer that sits under the font
base but on the bench top. This stops warping of the base plate. Ensure
the Tap spout is directly centered over the Font drain. Fit the “Spider
Clamp”, nut and washer onto the “All Thread”. Have all the supply tubes
and USB cable located evenly between the “Spider Clamp” legs. When
satisfied with the positioning, tighten the fixing nut with the Tube Spanner
provided in the kit.
6. Tighten the securing pin so the Font base is flush with the bench top.
NOTE:
The fixing nut above the drain elbow can be loosened to correctly
position the direction of the elbow. Ensure when the re-positioning is
complete the nut is re-tightened to ensure a water tight seal.
7. Connect a drain hose (22mm ID) from the Font base outlet elbow to the
closest drain trap spigot available. If a spigot is not available use the snap
on spigot and worm drive clamps supplied in the kit. (Instructions and
diagrams are supplied in the kit ref:81496).
8. Ensure the positioning of the snap-on spigot is on the “sink” side of the
trap and not the “waste” side. Once positioned, a hole (13mm ID) will
need to be drilled to provide waste access to the drain line. The snap-on
unit will require suitable sealant to keep it water tight against the waste
pipe. Finish by fitting the worm drive clamps tightly on either side of the
spigot and fitting worm drive clamps to either end of the drain hose. The
drain hose from the Font must have constant fall
9. Connect the Tap head Assembly supply hoses and vent as per the
instructions contained in the installation procedure section of this
document.
Font installation procedure
Tap assy
hole 35mm
Hole required for Font
recess 108mm
Fixing stud
Drain elbow
View from underside
Cut a 10mm
slot for stud
Black
Plastic
Spacer
See note 4.
Note:
A stainless steel washer is
supplied to go in between the
Spider Clamp and the underside
of the benchtop. See location as
shown.
Spider
Clamp
Fixing nut
S/S Washer
Tap
All-thread rod
Benchtop
Font
Spacer
Under Font
*
Summary of Contents for HydroTap
Page 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...
Page 12: ......
Page 13: ......
Page 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...
Page 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...
Page 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...