Quick Start Installation Guide
807042 v1.02 08.22 HydroTap G5 UltraCare Install Instructions
25
13.3 Install the filter cartridge
• Unpack filter cartridge.
• Remove dust cap and set aside in a clean area
for use later.
SECTION 13: Commissioning
• Write today’s date where shown on the label.
• Avoid touching the filter o-rings and
filter opening as this may cause bacterial
contamination of the cartridge.
• Moisten the o-rings with water.
• Open the filter door on the Command Centre.
• Push the new cartridge up into the filter head.
• Turn the cartridge a quarter turn to the right
until it comes to a complete stop and locks.
13.4 Set the date, time & drain away options
• Touch the date and time, use "-" or "+" to
make adjustments. When ready, touch
the arrow to continue.
• Select 'Sink / Container' or 'Font'
depending on the model , see below.
• Select 'Font' if the HydroTap is mounted
on a font.
• Select 'Sink / Container' if the HydroTap
is mounted such that the waste water
dispenses into a sink, or container.
• Note
This selection
will determine if
water is dispensed
automatically or
requires operation
of the tap during the
tank flush process.
• Touch the arrow to
continue.
Font
Sink
Container