 SECTION 3: Command Centre Screen

3.5.4 Dispense times

Set the “bottle fill” dispense time for each water type.
Minimum dispense time: 5 seconds.
Maximum dispense time: 15 seconds (default).

3.5.5 Light sensor

Follow the on screen instructions. 
Ensure the ambient light in the room is typical for 
operating conditions. 
The lights on the tap will flash to confirm calibration.
When the room is darkened below the calibrated light 
level, the tap lights will turn OFF after 30 seconds. Energy 
saving modes may occur. Refer to section 3.7 (page 31).

LIGHT SENSOR

12:12  PM

CALIBRATION

This will calibrate the light sensor which will allow the 

system to go to sleep when it is dark.

Before we start, the room should be in a typical

ambient lit environment.

Remove any object away from the tap.

Summary of Contents for HydroTap G5 BA60

Page 1: ...806835 v1 02 05 21 G5 User guide 1 UserGuide HydroTap G5 Visit our website to download the manuals Australia UK...

Page 2: ...806835 v1 02 05 21 G5 User guide 2...

Page 3: ...1 Filter settings 19 3 5 2 Temperature settings 22 3 5 3 CO2 settings 24 3 5 4 Dispense times 26 3 5 5 Light sensor 26 3 5 6 Quiet mode 27 3 5 7 Advanced settings 1 27 3 5 8 Advanced settings 2 Wave T...

Page 4: ...806835 v1 02 05 21 G5 User guide 4 Navigate to the register product menu Scan the QR code and follow the on screen steps to register your product Register product...

Page 5: ...c shock Hot surface SECTION 1 SAFETY 1 2 Before you start Read the WARNINGS and PRECAUTIONS Download read the complete Command Centre installation instruction manual and user guide Read and use the in...

Page 6: ...6 SECTION 2 Using the HydroTap SAFETY BOILING CHILLED CHANGE FILTER SAFETY Touch free Classic Arc Cube and Celsius HydroTap Mixer Taps Touch Free Wave Classic Plus Elite Plus See page 6 See page 7 Se...

Page 7: ...lled Sparkling Boiling ON Ready to dispense FLASHING SLOWLY Water temperature not at set point FLASHING QUICKLY System fault Simply press to dispense chosen water type Safety lock Safety lock Info ON...

Page 8: ...ensors activated water dispensed BLUE Chilled sensor activated water dispensed WHITE Sparkling sensor activated water dispensed PURPLE Lock mode on when tap is idle Flashing RED Sensor activated incor...

Page 9: ...s Sensor range 1 4cm To dispense hold hand within range of the sensors Tap will not operate and light will flash if the sensors are touched or if your hand is too close Boiling Water Chilled Ambient S...

Page 10: ...ct touch to select water type SAFETY SAFETY SAFETY SAFETY LOCK ON Lights Indicator Select Safety SAFETY ON Ready to dispense ALL LIGHTS FLASH CONTINUOUSLY System fault refer to Command Centre LCD Hydr...

Page 11: ...spense Lights BOILING CHILLED CHANGE FILTER SAFETY Dispense options Boiling ready Chilled sparkling ready Filter Use boiling chilled sparkling or ambient lever to dispense your water choice SAFETY SAF...

Page 12: ...806835 v1 02 05 21 G5 User guide 12 SECTION 2 Using the HydroTap 2 5 HydroTap Mixer taps Controls mixed water Hot Cold Lift and rotate the lever to dispense mixed warm water...

Page 13: ...reen Here s an example Set the language from the home screen Touch the top left icon to navigate to the main menu Then touch the general settings icon to navigate to the general settings menu MAIN MEN...

Page 14: ...d Centre ON or OFF The LCD screen visually shows OFF when it is non operational You will hear the sound of an internal click as the HydroTap Command Centre turns ON or OFF When OFF all functions are d...

Page 15: ...lled models CO2 gas remaining Sparkling models 12 12 PM 0 CO2 GAS REMAINING REPLACE CO2 GAS When the CO2 cylinder has approximately 20 remaining a warning appears to encourage you to prepare a replace...

Page 16: ...21 G5 User guide 16 SECTION 3 Command Centre Screen 3 3 Main menu Use the Main menu to configure your HydroTap and access features and settings Touch each icon to access further options 3 4 General se...

Page 17: ...7 SECTION 3 Command Centre Screen Date and time Touch the text boxes on the screen and then press and to set the current date and time Press the tick to confirm and save Network Connect to Wi Fi avail...

Page 18: ...806835 v1 02 05 21 G5 User guide 18 3 5 System settings Configure your HydroTap to suit your needs Navigate to system settings screen for all system settings SECTION 3 Command Centre Screen...

Page 19: ...ing of a new installation and after every filter change See page 35 for filter change instructions 3 5 1 Filter settings FILTER SETTINGS 12 12 PM Filter Reset Filter Life Filter Flush Tank Flush Open...

Page 20: ...w being flushed through the filter This process is automatic and will take 2 minutes Press pause to pause filter flush Approximately 10L of water will flow for 2 minutes The screen will show the filte...

Page 21: ...internal external filter and edit the filter life months or litres and actual usage days or litres When usage exceeds the filter life the tap lights and screen will indicate to change the water filter...

Page 22: ...igher temperature setting Up to 6 less energy in standby is consumed with a 98 C set point rather than 100 C A warning icon will appear when setting boiling set point temperatures that are subject to...

Page 23: ...from the tap spout On start up the HydroTap self calibrates or go to this menu to recalibrate Calibration will take around 10 minutes External Booster For selected commercial Boiling models an extern...

Page 24: ...pes from the tap The purge process stops automatically 3 5 3 CO2 settings 12 12 PM PURGE WATER WITH CO2 INFO This process removes water from the sparkling chamber when a new CO2 bottle is installed Th...

Page 25: ...o grams absorbed Months of use may also be selected to trigger a reminder to prepare a replacement CO2 cylinder Usage is dependent on CO2 absorption settings on the HydroTap and leak free installation...

Page 26: ...room is typical for operating conditions The lights on the tap will flash to confirm calibration When the room is darkened below the calibrated light level the tap lights will turn OFF after 30 secon...

Page 27: ...se Power Pulsing Mode Hot setpoint must be 98 5 C to disable Periodic Pulse Reduced Cavitation Mode Sends two electric pulses every 5 minutes to the pump This prevents the build up of air bubbles insi...

Page 28: ...kling Wave Tap Sensor Demister Mode Enabled default activates the Wave Tap internal heater to prevent its sensors from being affected by condensation from steam Disabled choose this option to conserve...

Page 29: ...ety button to dispense hot water Hot isolation additional boiling safety 3 slow safety button presses required prior to dispensing Boiling safety lock Enabled default safety button must be touched tap...

Page 30: ...protect Activate passcode protection to limit access to certain settings Users will be prompted for this passcode when attempting to access settings Create a 4 digit passcode and re enter as prompted...

Page 31: ...bled default Enabled Any attempt to dispense water will bring the HydroTap out of sleep mode Allow sufficient time for the water to reach the set temperature Sleep when Select from It gets dark Not us...

Page 32: ...ghted When OFF the HydroTap will stop chilling and heating the drinking water During OFF mode any attempt to dispense water will bring the HydroTap back ON Allow sufficient time for the water to reach...

Page 33: ...et 3 7 3 Energy Use Track energy usage of your HydroTap by viewing the total energy consumed and the energy consumed since the last energy use reset 12 12 PM SET TIMER Off at On at Mon Tue Wed Thu Fri...

Page 34: ...cent Faults ABOUT SYSTEM 12 12 PM Title Info Module App revision Serial No Product No Calibration 50L Filtered Wi Fi MAC Address BCS100 017 H5v0 1 xx 0000000000000 H500xx000AU N A N A BS 0 00 FW 0 00...

Page 35: ...he filter may require changing before the filter change indication is shown You may also need to replace the filter if you notice an increase in chlorine taste or odour Place a cloth or towel under th...

Page 36: ...ge 19 Clean up and dispose of old cartridge and packaging If the HydroTap is switched off for a long period of time e g more than a weekend run water through the chilled water outlet for at least 60 s...

Page 37: ...tenance 4 2 Air inlet filter maintenance Remove and clean quarterly Rinse off with tap water Gently dry with a cloth or towel Maintain at least a 50mm air gap in front of the air inlet screen at all t...

Page 38: ...y immediately with a clean dry cloth Do not use strong corrosive spray or abrasive cleaners Command Centres must never be located near or cleaned with water jets For the Touch Free Wave Tap Do not use...

Page 39: ...I I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I I I IIII...

Page 40: ...I I I I IIIIIIIII I I I I I I I Cylinder pressure Outlet pressure Regulator control knob Cylinder connection Gas hose connection Set to 3 0 bar SECTION 4 User maintenance Universal G5 CO2 regulator 1...

Page 41: ...IIIIIIIII I I I I I I I I I I I I I I I I Replace cylinder and refit regulator I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I...

Page 42: ...I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I...

Page 43: ...strap Unscrew regulator connection Replace cylinder and refit regulator Strap in place Turn ON regulator valve Test for leaks in these areas Test for leaks by brushing with soapy water and looking for...

Page 44: ...77 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia 612 9796 3100 Free Call Aust 1800 947 827 www zipwater com Zip Water UK Trafalgar House Rash s Green Dereham Nor...

Reviews: