803341NZ - Tap Installation Instructions - Jun 2016 - v2.00
Page 3 of 16
BLACK
PLASTIC
SPACER
1.3
Installation Instructions
Pass all the hoses, tubes and USB lead
through the 35mm hole.
1.4
35mm hole
Note
Note
:
feed each of the three tubes and
electrical cable evenly in between the legs of
the SPIDER CLAMP when installing.
Fit the
STAINLESS STEEL
WASHER,
SPIDER CLAMP,
AND 6mm NUT.
6mm NUT
SPIDER CLAMP
STAINLESS
STEEL WASHER
Incoming water
Blue hose
to chilled
water outlet
Red hose to boiling
water outlet
Clear hose to
Vent
1.5
Note:
- Mains hose
length is 750mm
- Plug and Cord
length is 1800mm
Position the under
sink unit close
to the outlet tap,
within reach of
the hose and cord
lengths supplied
Note:
Note:
All
All
silicon tubes
silicon tubes
must be cut to
must be cut to
size. They must
size. They must
have a constant
have a constant
fall back to the
fall back to the
unit.
unit.
Typical HydroTap Installation (see section 5)