Zip HydroTap BC100/75 Operating Instructions Manual Download Page 32

Page 32 of 32 

802411US v1.27 06.21 BC, BC100-75 Install Instructions

Manufactured by: Zip Water (Aust) Pty Ltd

67 Allingham Street, Condell Park NSW 2200 Australia

Distributed in US and Canada by: Culligan International Company

9399 West Higgins Road, Suite 1100, Rosemont, IL 60018

www.us.zipwater.com

Call US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries.

As Zip policy is one of continuous product improvement, changes to specifications may be made 

without prior notice. Images in this booklet have been modified and may not be true representations of 

the finished goods.

The terms “Zip” and “HydroTap” are registered trade marks of Zip Water (Aust) Pty Ltd. 

BC – Classic XX, BC – ARC XX, BC – CUBE XX, BC100/75 – Classic XX, BC100/75 – CUBE XX and 

BC100/75 – ARC XX have been tested and certified by WQA against NSF/ANSI Standard 372 for low 

lead requirement, against NSF/ANSI Standard 42 and NSF/ANSI Standard 53. This will deliver the re-

quired bacteriostatic effect and the reduction of aesthetic chlorine, taste, odor, nominal particulate Class 

I (≥ 0.5 µm to < 1 µm), cyst and lead as verified and substantiated by test data. See Performance Data 

Sheets for specific performance claims. Certified performance claims are only valid when filter cartridge 

1Z-LS (Culligan Part Number 01034276) is used.

BC - Classic XX, BC – ARC XX, BC - CUBE XX, BC - Wave XX, BC100/75 - Classic XX, BC100/75 - 

CUBE XX and BC100/75 - ARC XX have been certified by IAPMO R&T against NSF/ANSI Standard 

372 for low lead requirement, NSF/ANSI Standard 42, NSF/ANSI Standard 53, CSA B483.1, ASSE 

1023, and ASSE 1087. This will deliver the required bacteriostatic effect and the reduction of aesthetic 

chlorine, taste, odor, nominal particulate Class I (≥ 0.5 μm to < 1 μm), cyst and lead as verified and 

substantiated by test data. See Performance Data Sheets for specific performance claims. Certified 

performance claims are only valid when filter cartridge 1Z-LS (Culligan Part Number 01034276) is used. 

© 2021 Zip Water (Aust) Pty Ltd

Summary of Contents for HydroTap BC100/75

Page 1: ...US v1 27 06 21 BC BC100 75 Install Instructions Page 1 of 32 BC100 75 and BC Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document English F...

Page 2: ...he customer s needs For ease of installation it is recommended to fit the faucet before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Insta...

Page 3: ...ation instruction book STEP 2 Check for adequate ventilation Section 2 Ventilation 2 1 Ventilation for all models 11 2 2 Cabinet air circulation 12 13 STEP 3 Install the Command Center Section 3 Comma...

Page 4: ...k the appliance rating plate and ensure correct power is available for the appliance G Check the under counter cabinet supporting the appliance is adequate for the total weight of the appliance when f...

Page 5: ...efrigerant compressor to chill the water and an immersion heating element to boil the water These Command Centers dispense boiling water factory set to 98 C 208 F and chilled water factory set to 6 10...

Page 6: ...rocedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or condensed droplets...

Page 7: ...r HydroTap HydroTap models are rated for either 110 120V 60Hz OR 230V 50Hz AC installations 6 Command Centers must never be located near or cleaned with water jets 7 Zip HydroTaps are not to be expose...

Page 8: ...d water filters 1x Mains water connection hose Vent Kit 1x Inlet vent 1x Outlet vent 9 x Screws 1x Installation Instructions this book and 1x User Guide Accessories Description Font Drip Tray Kit for...

Page 9: ...efers to the specific finish of the faucet BC Classic XX BC ARC XX BC CUBE XX BC100 75 Classic XX BC100 75 CUBE XX and BC100 75 ARC XX have been tested and certified by WQA against NSF ANSI Standard 3...

Page 10: ...nside the cabinet within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centers are installed A cold water supply with...

Page 11: ...m Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps are achieved...

Page 12: ...r the inlet vent See Item B below and silicone buffers need to be fitted If the airflow is still insufficient to maintain normal operating temperatures then the door outlet vent See item D below will...

Page 13: ...d cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure wi...

Page 14: ...ect the plug into the electrical power outlet ensuring both ends are securely engaged to reduce the risk of overheating Section 3 Command Center Installation B Rotate 90 only 1 2 3 4 A Rotate 90 only...

Page 15: ...y pulling back on the tube If the tube comes out of the fitting repeat the above step 5 To remove the tube press the collet into the fitting and at the same time pull back on the tube 3 3 Hose and tub...

Page 16: ...HydroTap models Note The tube lengths are matched to the pump performance and therefore CANNOT be lengthened 336mm 13 5 Connector Strainer Min 50mm 2 side clearance Note Mains hose length is 750mm 30...

Page 17: ...label To install the cartridge align the key tabs and insert upwards into the filter head Turn the cartridge to the right until it locks in place Have a 10 liter 2 6 gallon bucket or similar containe...

Page 18: ...efore it is recommended that a re calibration be performed at the time of the installation All direct natural sun light must be shaded from the HydroTap during the calibration This can be achieved by...

Page 19: ...ser sensor Open Internal fault Check ventilation Call Zip service Heater fuse driver fault Internal fault Call Zip Service Heater driver fault No hot water Call Zip Service Compressor driver fault No...

Page 20: ...nment we ask that you dispose of this product correctly This product should not be treated as domestic waste but should be taken to a dedicated recycling center for electrical and electronic equipment...

Page 21: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Page 22: ...n or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Red...

Page 23: ...an or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Re...

Page 24: ...imit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Redu...

Page 25: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requ...

Page 26: ...the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requir...

Page 27: ...the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requir...

Page 28: ...replace the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is in...

Page 29: ...Zip Servicer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is commit...

Page 30: ...Page 30 of 32 802411US v1 27 06 21 BC BC100 75 Install Instructions Notes...

Page 31: ...802411US v1 27 06 21 BC BC100 75 Install Instructions Page 31 of 32 Notes...

Page 32: ...ndard 42 and NSF ANSI Standard 53 This will deliver the re quired bacteriostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to 1 m cyst and lead as ver...

Reviews: