16
Installation instructions & user manual
806143UK V1.00 July 2019 - HydroChill HC45
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
Installation - Section 7 Commissioning
!
Operation
Pull
HydroChill Twin lever - Chilled ambient
• The lever on the right is used for chilled filtered water and the other, on the left, is
used for ambient filtered water.
• Chilled water is obtained by pulling the lever on the right forward, The water is
chilled by a refrigeration unit fitted within the chiller unit.
• Chilled water can be obtained within the rated capacity, for as long as you pull the
lever forward. Ambient water is obtained in the same manner as the chilled water, by
pulling the lever on the left forward, to the horizontal position.
• The levers will self return, and close the tap once finger pressure has been removed.
HydroChill heavy duty - Chilled only
• Chilled water is obtained by pulling the lever on the tap forward. The water is chilled
by a refrigeration unit fitted within the under counter chiller.
• Using the Heavy Duty HydroChill you can obtain chilled water within the rated
capacity for as long as you pull forward the lever. The lever will self return, and close
the tap once finger pressure has been removed.
Pull
7.0 Commissioning
Due to the sanitisation process, residue from the sanitisation liquid might remain in the product, which
requires the products to be flushed with fresh water at installation. So the first few glasses of water may
look soapy with presence of bubbles. As part of the purge process, dispense 10 litres of water from the tap,
then check that the water is clear, and that there are no soapy looking bubbles in the dispensed water.
• All HydroChill model must be sanitised during the commission process, please contact Zip on 03456 005 005 to
book your free commissioning service.
•
Do not commission your HydroChill until ready for use.
• Secure all pipes and cables. After the system is correctly installed and connected, turn the incoming mains cold
water supply on then purge the system of air (follow the instruction in the Filter replacement, page 17).
• Check all connections for leaks. Repair as necessary, again turn the incoming mains cold water supply on,
re-purge and then turn on the mains electricity supply.
• The chiller unit takes up to 20 minutes to chill it’s contents to the rated temperature, depending on the ambient
temperature of the water.
• Ensure your HydroChill is sanitised before use.`
• If your HydroChill is left idle before use for water taste and quality reasons any non-use of more than 48 hours,
Zip recommend a system flush be performed. On first use after a period of non-use, run the chilled / ambient
water functions for 60 seconds to flush the filter and system. Not flushing the system may affect water the
quality. If taste or water quality issues persist, a filter change and sanitisation may be required.