Page 6 of 16
Zip Hydroboil Plus- Installation & Operating Instructions - 82869 - May 2003
d) Electrical
For concealed electrical connection, connect a power cable through the rear
access opening of the heater to the terminal block within the heater as shown.
For exposed electrical connection, connect a flex to a standard 13 amp double
pole fused spur power outlet on the wall within 1500 mm of the heater.
Do not turn the power ON until the heater is filled with water.
All isolation switches must have a contact seperation of at least 3 mm in all poles.
Step 4 – Assembling
Place the heater case back on to the heater and secure the top 2 case screws.
Place outlet nozzles on nozzle fascias at base of the heater and secure screws.
Secure two bottom case screws.
Installation Procedures
continued
274 (1.5 L & 3.O L)
304 (5.0 L & 7.5 L)
38 (1.5 L & 3.0 OL)
53 (5.0 L & 7.5 L)
65 CLEAR
56
POSITIONING PIN
EXTERNAL PLUMBING
ELECTRICAL WIRING
POSITION
INTERNAL PLUMBING
72
15
25
35
42
COLD
INLET
VENT
BENCH TOP
318 5.O L
416 3.O L
448 5.O L
561 7.5 L
38 (1.5 L & 3.O L)
53 (5.0 L & 7.5 L)
150
CLEAR
19
20
Wall Mounting Template Dimensions & Electrical Diagram
3 Lt, 5 Lt & 7.5 Lt HB SINGLE ELEMENT
WITH NMS PCB CONTROLLER WIRING DIAGRAM