Zip FL104 Installation Instructions Download Page 3

3

INSTALLATION INSTRUCTIONS 

T210025 V2.00 JUNE 2018 - ZIP FL064, FL104

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK  

WWW.ZIPWATER.CO.UK

 INSTALLATION INSTRUCTIONS

FL064

FL104

275mm

165mm

Existing Pipework

Existing Pipework

Remove 275mm of existing pipework to feed in filter

Remove 165mm of existing pipework to feed in filter

ø54

ø54

FL064

FL104

275mm

165mm

Existing Pipework

Existing Pipework

Remove 275mm of existing pipework to feed in filter

Remove 165mm of existing pipework to feed in filter

ø54

ø54

Preparation

 (if fitting to existing pipework)

Installation

•  Fit the filter in the incoming mains cold water supply line to the appliance.
•  Turn off the incoming cold mains water supply.
•  Note the flow direction on the filter (marked with an arrow).
•  Connect supply line to the inlet side of the filter. 
•  Tighten firmly, using two spanners (do not over tighten).
•  Turn on the water supply.
•  Flush 18 litres of water through the filter (use a length of hose on the outlet of filter and drain to waste).
•  Turn off water supply.
•  Connect filter outlet. 
•  Tighten firmly using two spanners.
•  Turn on water supply.
•  Check for leaks and tighten fittings if leaks occur.

Dimensions

FL064  215mm x 

Ø

50mm (max).

FL104  315mm x 

Ø

50mm (max).

Reviews: