801314UK - G4 Boiling chilled commercial installation instructions - June 2016 - V2.04
Page 11 of 28
Section 1
Ventilation
When installing air flow vents, the following tools will be required
•
Jigsaw and drill.
•
Keyhole or wall board saw.
Important
See section 4 Command-Centre
TM
installation,
pages 17 to 21.
Vent cut-out details
A
Air outlet vent
B
Air inlet vent
1.1 Preferred ventilation arrangement shown below.
The ducted vent kit supplied with the Command-Centre
TM
exhausting through the kick-space should be used,
to provide adequate ventilation in all conditions. (Ancillary components are not shown in these diagrams).
A
B
C
C
Ducted vent
100mm
min.
Inlet grille
Position vent grille on
either the kick board or the
cupboard ends
Inlet grille should be
fitted in baseboard
A
Cupboard back must be
fully closed to prevent
recirculation into
cupboard from
kick space.