Zip CEX-O Installation, Maintenance And User Instruction Download Page 13

CEX-O & CEX-U Installation, Maintenance and User Instructions - August 2011

12

Fig 10

Service menu

The service menu can be used for diagnostics
and to view and configure appliance settings.

Press program keys 1 and 2 simultaneously for
at least 2 seconds to enter the service menu
confirmed by the display “FL” and flashing
point (see Fig 10).

Scroll between menu items in the service menu
using the arrow up and arrow down keys.

Press program key 1 to display the value of the
currently selected menu item. The value flashes
in the display.

The values of some menu items can be
displayed by using the arrow up and arrow
down keys.

Press program key 1 to return to the menu
item list.

Press program key 2 to exit the service menu
and return to the standard display.

After two minutes without any key stroke the
system automatically returns to the standard
display.

Menu item order of Service Menu:

Flow:

Flow rate (l/min)

Power:

Power consumption (kW)

Temp in:

Inlet temperature (°C)

Temp out:

Outlet temperature (°C)

Control value:

Calibration value of the control system (40 - 60)

Power limit:

Maximum power setting (kW)

Diagnostics:

Last ten diagnostic messages (see below)

Lock level:

Current lock level setting (see below)

Software version:

Installed software version

Radio channel:

Radio channel of heater and remote control

Received strength:

Signal quality of remote control (10% - 100%)

Signal:

Quality of radio contact with diagnostic display

Press >2 secs

Display flashes

1

2

4

5

6

7

8

9

3

CEX pages qxd:Varipoint qxd  30/8/11  14:27  Page 11

Summary of Contents for CEX-O

Page 1: ...the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham Norfolk NR19 1TE Telephone 0845 6024533 Facsimile 01362 692448 www zipheaters co uk Zip InLine Electronically Controlled...

Page 2: ...alled and used strictly in accordance with the instructions supplied and that failure is not due to accident misuse abuse unsuitable water conditions or to any alteration modification or repair by any...

Page 3: ...red temperature is achieved exactly to the degree and irrespective of fluctuations in voltage and water pressure The power rating of the appliance can be selected as either 9 6kW or 7 2kW at 240V at t...

Page 4: ...he hot water tap until all air has been eliminated from the water heater and no more air emerges before re connecting to the electrical supply The front cover of the appliance must never be opened bef...

Page 5: ...min 5 0 2 Pressure loss 2 5 l min 0 2 bar 9 0 l min 1 3 bar 3 Temperature setting range 30 C 55 C Maximum weight kg 2 70 Dimensions H x W x D mm 294 x 177 x 108 Water connections BSP Protection class...

Page 6: ...Dimensions 5 CEX O CEX U Installation Maintenance and User Instructions August 2011 294 108 177 100 37 CEX pages qxd Varipoint qxd 30 8 11 14 27 Page 4...

Page 7: ...e IN82812 CEX U IN82816 CEX O Control Panel IN82811 Main PCB IN82246 Non return Valve IN82819 Flow Sensor IN86250 Terminal Block IN82806 Grommet IN82813 Water Connection IN82512 Temperature Sensor Set...

Page 8: ...on and ensure that the wiring is not directly accessible after installation Check that the power supply is switched off prior to electrical connection This appliance must be earthed Installation site...

Page 9: ...s see Fig 2 4 Drill the holes using a 6mm drill then insert the dowels and screws provided leaving the screws protruding 5mm from the wall 5 Hang the appliance with the screws engaging in the key hole...

Page 10: ...wiring is not directly accessible after installation To protect the appliance a circuit breaker must be fitted with a rating suitable for the nominal current of the appliance Check that the power supp...

Page 11: ...e sizing and fuse protection is in place and with regard to local site conditions and electrical regulations This should only be done by a competent installer 1 Switch on the power supply to the appli...

Page 12: ...e maximum power rating has been selected Lock level Operation of the appliance can be restricted Refer to instructions under Service Menu to set the lock level This should only be done by a competent...

Page 13: ...to the menu item list Press program key 2 to exit the service menu and return to the standard display After two minutes without any key stroke the system automatically returns to the standard display...

Page 14: ...erating mode of the appliance can be restricted Setting options 0 no restriction factory setting 1 disables Reset to factory setting Parameters can be viewed but not modified in service menu 2 as 1 ad...

Page 15: ...d outlet temperature can be adjusted between 30 C and 55 C Note reducing the temperature below 30 C displays and the heating function will not operate Program buttons The two program keys allow a pres...

Page 16: ...to confirm deactivation Note Programmed temperature settings may need to be reset after deactivating temperature limitation Reset to factory setting To reset to factory settings press the up arrow an...

Page 17: ...more than one outlet Power limit If the maximum power available from the appliance is insufficient to heat the volume of hot water being drawn off to the required temperature this will be indicated b...

Page 18: ...r heaters Plastic surfaces and sanitary fittings should only be wiped with a damp cloth Never use abrasive cleaning agents or solvents Outlet fittings tap nozzles and shower heads should be unscrewed...

Reviews: